Release of monomers from four different composite materials after halogen and LED curing.

Olga Polydorou1, Armin König, Markus Jörg Altenburger, Martin Wolkewitz, Elmar Hellwig, Klaus Kümmerer.   

Abstract

PURPOSE: To evaluate the release of monomers from four different composite materials (Ceram X, Filtek Supreme XT, Tetric Flow, Tetric EvoCeram), polymerized using either halogen or LED unit.
METHODS: Ten specimens were made for each material/unit combination. Each specimen was stored in 1 ml 75% ethanol. The storage medium was renewed after 1, 7 and 28 days. Aliquots of this medium were analyzed by LC-MS/MS.
RESULTS: The effect of the curing unit on monomers' release differed significantly among the materials (P < 0.0001). The amount of BisGMA and TEGDMA released from Ceram X was not influenced by the unit used (P > 0.05). Curing with LED reduced the amount of Bisphenol A released from Ceram X compared to halogen. For Filtek Supreme XT, the type of unit exerted a significant effect on the elution of BisGMA (P < or = 0.05). LED curing resulted in a higher release of TEGDMA and UDMA compared to halogen (P < or = 0.05). For Tetric Flow, LED curing resulted in lower monomer release (P < 0.0001). For Tetric EvoCeram, the amounts of BisGMA, UDMA and Bisphenol A were higher when polymerizing with LED compared to halogen. The release of substances was more material dependent and less influenced by the curing unit used.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22165461

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522