Literature DB >> 22136965

Local diagnostic reference levels for typical radiographic procedures.

Elena Tonkopi1, Cupido Daniels, Mary J Gale, Stephanie C Schofield, Vicki A Sorhaindo, Jeanne L Vanlarkin.   

Abstract

PURPOSE: To establish local diagnostic reference levels (DRL) for typical radiographic examinations in a fully digital imaging institution.
METHODS: The initial survey included 6 standard radiographic projections performed in 19 computed radiography (CR) and digital radiography (DR) rooms. Because of the expected difference in the performance, the local reference levels were analysed separately for those 2 modalities. Data of 226 average size adult patients were included in the analysis. Entrance surface dose (ESD) was calculated from the recorded radiographic techniques and tube radiation output measurements. After observing wide variations in the results of the patient survey, the examinations were repeated by using anthropomorphic phantoms. Initial efforts to understand the reasons for dose variations were focused on CR chest, abdomen, pelvis, and lumbar spine examinations.
RESULTS: The average size patient doses for similar examinations were lower in the DR rooms than in the CR rooms by factors that ranged from 1.2 to 3, with the exception of the chest examination. Standardization of the CR exposure index value allowed us to decrease ESD by 21%-30%. Detector sensitivity had an insignificant effect (2%) on ESD; proper collimation lowered the dose by 17%. However, the major effect, up to 46% difference, was found because of antiscatter grids cutoff.
CONCLUSION: Modality specific local diagnostic reference levels for standard examinations have been established in a large digital imaging department with hybrid modalities. Typically the local reference values were lower than those recommended in Safety Code 35, except for CR chests. Factors that affect the dose variations have been investigated and determined.
Copyright © 2012 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22136965     DOI: 10.1016/j.carj.2011.02.004

Source DB:  PubMed          Journal:  Can Assoc Radiol J        ISSN: 0846-5371            Impact factor:   2.248


  3 in total

1.  New developed DR detector performs radiographs of hand, pelvic and premature chest anatomies at a lower radiation dose and/or a higher image quality.

Authors:  Helle Precht; Anders Tingberg; Dag Waaler; Claus Bjørn Outzen
Journal:  J Digit Imaging       Date:  2014-02       Impact factor: 4.056

2.  Variation of Pediatric Doses Undergoing Digital and Computed Radiography Examination in Addis Ababa, Ethiopia.

Authors:  Seife Teferi; Daniel Zewdeneh
Journal:  Ethiop J Health Sci       Date:  2020-03

Review 3.  Digital radiography exposure indices: A review.

Authors:  Ursula Mothiram; Patrick C Brennan; Sarah J Lewis; Bernadette Moran; John Robinson
Journal:  J Med Radiat Sci       Date:  2014-05-11
  3 in total