Variable flip angle schedules in bSSFP imaging of hyperpolarized noble gases.

Martin H Deppe1, Jim M Wild.   

Abstract

Balanced steady-state free precession imaging sequences provide signal-to-noise ratio benefits for MRI of hyperpolarized nuclei. Hyperpolarized magnetization decays during the imaging sequence to thermal equilibrium, effectively necessitating imaging in a transient state characterized by nonconstant transverse magnetization and k-space filtering when using constant flip angles. This work presents an analytical method for calculation of variable flip angle schedules which maintain constant transverse magnetization in balanced steady-state free precession imaging of hyperpolarized nuclei. The approach is based on direct inversion of the Bloch equations and does not require any numerical optimization. Input parameters are pulse sequence timings and effective relaxation times, which take diffusion of hyperpolarized gas in imaging gradients into account. Provision of constant transverse magnetization is demonstrated in phantom experiments and human lung imaging using hyperpolarized (3) He. The benefit of a flat k-space filter is demonstrated by reduced blurring in (3) He and digital phantom data, and high quality (3) He ventilation images from human lungs are obtained.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22134846     DOI: 10.1002/mrm.23155

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

Review 1.  3He diffusion MRI in human lungs.

Authors:  Jason C Woods; Mark S Conradi
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

2.  Optically polarized 3He.

Authors:  T R Gentile; P J Nacher; B Saam; T G Walker
Journal:  Rev Mod Phys       Date:  2017-12-11       Impact factor: 54.494

Review 3.  Hyperpolarized gas MRI in pulmonology.

Authors:  Agilo Luitger Kern; Jens Vogel-Claussen
Journal:  Br J Radiol       Date:  2018-01-22       Impact factor: 3.039

4.  Motion-robust, high-SNR liver fat quantification using a 2D sequential acquisition with a variable flip angle approach.

Authors:  Ruiyang Zhao; Yuxin Zhang; Xiaoke Wang; Timothy J Colgan; Jennifer L Rehm; Scott B Reeder; Kevin M Johnson; Diego Hernando
Journal:  Magn Reson Med       Date:  2020-04-03       Impact factor: 4.668

5.  High resolution (13)C MRI with hyperpolarized urea: in vivo T(2) mapping and (15)N labeling effects.

Authors:  Galen D Reed; Cornelius von Morze; Robert Bok; Bertram L Koelsch; Mark Van Criekinge; Kenneth J Smith; Peder E Z Larson; John Kurhanewicz; Daniel B Vigneron
Journal:  IEEE Trans Med Imaging       Date:  2013-10-25       Impact factor: 10.048

6.  Fast Determination of Flip Angle and T1 in Hyperpolarized Gas MRI During a Single Breath-Hold.

Authors:  Jianping Zhong; Weiwei Ruan; Yeqing Han; Xianping Sun; Chaohui Ye; Xin Zhou
Journal:  Sci Rep       Date:  2016-05-12       Impact factor: 4.379

Review 7.  Acquisition strategies for spatially resolved magnetic resonance detection of hyperpolarized nuclei.

Authors:  Geoffrey J Topping; Christian Hundshammer; Luca Nagel; Martin Grashei; Maximilian Aigner; Jason G Skinner; Rolf F Schulte; Franz Schilling
Journal:  MAGMA       Date:  2019-12-06       Impact factor: 2.310

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.