Landmark identification errors on cone-beam computed tomography-derived cephalograms and conventional digital cephalograms.

Zwei-Chieng Chang1, Fu-Chang Hu, Eddie Lai, Chung-Chen Yao, Mu-Hsiung Chen, Yi-Jane Chen.   

Abstract

INTRODUCTION: In this study, we investigated the landmark identification errors on cone-beam computed tomography (CBCT)-derived cephalograms and conventional digital cephalograms.
METHODS: Twenty patients who had both a CBCT-derived cephalogram and a conventional digital cephalogram were recruited. Twenty commonly used lateral cephalometric landmarks and 2 fiducial points were identified on each cephalogram by 11 observers at 2 time points. The mean positions of the landmarks identified by all observers were used as the best estimate to calculate the landmark identification errors. In addition to univariate analysis, regression analysis of landmark identification errors was conducted for identifying the predicting variables of the observed landmark identification errors. To properly handle the multilayer correlations among the clustered observations, a marginal multiple linear regression model was fitted to our correlated data by using the well-known generalized estimating equations method. In addition to image modality, many variables potentially affecting landmark identification errors were considered, including location and characteristics of the landmark, seniority of the observer, and patient information (sex, age, metallic dental restorations, and facial asymmetry).
RESULTS: Image modality was not the significant variable in the final generalized estimating equations model. The regression coefficient estimates of the significant landmarks for the overall identification error ranged from -0.99 (Or) to 1.42 mm (Ba). The difficulty of identifying landmarks on structural images with multiple overlapping--eg, Or, U1R, L1R, Po, Ba, UMo, and LMo--increased the identification error by 1.17 mm. In the CBCT modality, the identification errors significantly decreased at Ba (-0.76 mm).
CONCLUSIONS: The overall landmark identification errors on CBCT-derived cephalograms were comparable to those on conventional digital cephalograms, and Ba was more reliable on CBCT-derived cephalograms.
Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22133963     DOI: 10.1016/j.ajodo.2011.06.024

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  9 in total

1.  Cephalometric evaluation of rapid and slow maxillary expansion in patients with BCLP: Secondary data analysis from a randomized clinical trial.

Authors:  Leonardo Gregório; Arthur César de Medeiros Alves; Araci Malagodi de Almeida; Rodrigo Naveda; Guilherme Janson; Daniela Garib
Journal:  Angle Orthod       Date:  2019-02-11       Impact factor: 2.079

2.  Pitfalls at the root of facial assessment on photographs: a quantitative study of accuracy in positioning facial landmarks.

Authors:  M Cummaudo; M Guerzoni; L Marasciuolo; D Gibelli; A Cigada; Z Obertovà; M Ratnayake; P Poppa; P Gabriel; S Ritz-Timme; C Cattaneo
Journal:  Int J Legal Med       Date:  2013-03-21       Impact factor: 2.686

3.  Comparison between full face and hemifacial CBCT cephalograms in clinically symmetrical patients: a pilot study.

Authors:  Cintia Helena Zingaretti Junqueira; Guilherme Janson; Marisa Helena Zingaretti Junqueira; Lucas Marzullo Mendes; Eduardo Esberard Favilla; Daniela Gamba Garib
Journal:  Dental Press J Orthod       Date:  2015 Mar-Apr

4.  Comparison of linear measurements between CBCT orthogonally synthesized cephalograms and conventional cephalograms.

Authors:  S Yang; D G Liu; Y Gu
Journal:  Dentomaxillofac Radiol       Date:  2014-07-16       Impact factor: 2.419

5.  Changes in Cone-Beam Computed Tomography Pediatric Airway Measurements After Adenotonsillectomy in Patients With OSA.

Authors:  Chin-Nung Liu; Kun-Tai Kang; Chung-Chen Jane Yao; Yunn-Jy Chen; Pei-Lin Lee; Wen-Chin Weng; Wei-Chung Hsu
Journal:  JAMA Otolaryngol Head Neck Surg       Date:  2022-07-01       Impact factor: 8.961

6.  Morphology, incidence of bridging, and dimensions of sella turcica in different racial groups.

Authors:  Fenik Kaml Muhammed; Adil O Abdullah; Zhwan Jamal Rashid; Tamara Pusic; Mohammed F Shbair; Yi Liu
Journal:  Oral Radiol       Date:  2018-04-02       Impact factor: 1.852

7.  Effects of Type and Amount of Orthodontic Tooth Movement on Digital Model Superimposition Accuracy.

Authors:  Hasan Camcı; Farhad Salmanpour
Journal:  Turk J Orthod       Date:  2021-12

8.  The Effects of Additional Filtration on Image Quality and Radiation Dose in Cone Beam CT: An In Vivo Preliminary Investigation.

Authors:  Jan Houfrar; Bjorn Ludwig; Dirk Bister; Manuel Nienkemper; Ciamak Abkai; Adith Venugopal
Journal:  Biomed Res Int       Date:  2022-03-02       Impact factor: 3.411

9.  Evaluation of stability after pre-orthodontic orthognathic surgery using cone-beam computed tomography: A comparison with conventional treatment.

Authors:  Hye-Rim Ann; Young-Soo Jung; Kee-Joon Lee; Hyoung-Seon Baik
Journal:  Korean J Orthod       Date:  2016-09-19       Impact factor: 1.372