Literature DB >> 22133037

Health-related quality of life and treatment satisfaction in the Sensor-Augmented Pump Therapy for A1C Reduction 3 (STAR 3) trial.

Richard R Rubin1, Mark Peyrot.   

Abstract

OBJECTIVE: This study assessed health-related quality of life (HRQOL) and treatment satisfaction in sensor-augmented pump therapy (SAPT) compared with optimal conventional therapy-multiple daily injection (MDI) therapy with self-monitoring of blood glucose (SMBG)-in adults and children with type 1 diabetes and children's caregivers. Patient acceptance of new therapies is essential to their adoption and effective use. RESEARCH DESIGN AND METHODS: STAR 3, a randomized 12-month clinical trial, compared SAPT with MDI+SMBG in 485 adult and pediatric patients. Within- and between-treatment arm changes in generic HRQOL, diabetes-specific HRQOL (fear of hypoglycemia), and treatment satisfaction were assessed (significance criterion P<0.01).
RESULTS: In adults, children, and caregivers, there were no significant between-arm changes in generic HRQOL: SF-36 Physical Component Summary and Mental Component Summary scores in adults and the PedsQL Physical Health Summary and Psychosocial Health Summary scores in children or caregivers. Diabetes-specific HRQOL (Hypoglycemia Fear Survey Worry and Behavior subscale scores) improved more in SAPT than in MDI adults. Hypoglycemia Behavior scores improved more in SAPT caregivers. Key treatment satisfaction measures (Insulin Delivery System Rating Questionnaire measures of Convenience, Efficacy, and Overall Preference) improved more in SAPT adults, children, and caregivers (all P<0.001); all exceeded the criterion for minimal detectable difference.
CONCLUSIONS: In the first-ever large-scale study of SAPT compared with optimal conventional therapy, SAPT had significant advantages for hypoglycemia fear in adults and caregivers and for treatment satisfaction in adults, children, and caregivers.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22133037      PMCID: PMC4845679          DOI: 10.1089/dia.2011.0162

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  21 in total

1.  Crossing the technology divide: practical strategies for transitioning patients from multiple daily insulin injections to sensor-augmented pump therapy.

Authors:  Richard R Rubin; Sarah K Borgman; Becky T Sulik
Journal:  Diabetes Educ       Date:  2011-01-07       Impact factor: 2.140

2.  Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes.

Authors:  David M Nathan; Patricia A Cleary; Jye-Yu C Backlund; Saul M Genuth; John M Lachin; Trevor J Orchard; Philip Raskin; Bernard Zinman
Journal:  N Engl J Med       Date:  2005-12-22       Impact factor: 91.245

3.  Treatment satisfaction and quality of life for an integrated continuous glucose monitoring/insulin pump system compared to self-monitoring plus an insulin pump.

Authors:  Richard R Rubin; Mark Peyrot
Journal:  J Diabetes Sci Technol       Date:  2009-11-01

4.  Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes.

Authors:  Richard M Bergenstal; William V Tamborlane; Andrew Ahmann; John B Buse; George Dailey; Stephen N Davis; Carol Joyce; Tim Peoples; Bruce A Perkins; John B Welsh; Steven M Willi; Michael A Wood
Journal:  N Engl J Med       Date:  2010-06-29       Impact factor: 91.245

5.  Effect of technosphere inhaled insulin on quality of life and treatment satisfaction.

Authors:  Mark Peyrot; Richard R Rubin
Journal:  Diabetes Technol Ther       Date:  2010-01       Impact factor: 6.118

6.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.

Authors:  D M Nathan; S Genuth; J Lachin; P Cleary; O Crofford; M Davis; L Rand; C Siebert
Journal:  N Engl J Med       Date:  1993-09-30       Impact factor: 91.245

7.  Maternal fear of hypoglycemia in their children with insulin dependent diabetes mellitus.

Authors:  W L Clarke; A Gonder-Frederick; A L Snyder; D J Cox
Journal:  J Pediatr Endocrinol Metab       Date:  1998-03       Impact factor: 1.634

8.  Continuous glucose monitoring and intensive treatment of type 1 diabetes.

Authors:  William V Tamborlane; Roy W Beck; Bruce W Bode; Bruce Buckingham; H Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Irl B Hirsch; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Lori Laffel; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  N Engl J Med       Date:  2008-09-08       Impact factor: 91.245

9.  Psychometric properties of the hypoglycemia fear survey-ii for adults with type 1 diabetes.

Authors:  Linda A Gonder-Frederick; Karen M Schmidt; Karen A Vajda; Megan L Greear; Harsimran Singh; Jaclyn A Shepard; Daniel J Cox
Journal:  Diabetes Care       Date:  2011-02-23       Impact factor: 19.112

10.  Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: the RealTrend study.

Authors:  Denis Raccah; Véronique Sulmont; Yves Reznik; Bruno Guerci; Eric Renard; Hélène Hanaire; Nathalie Jeandidier; Marc Nicolino
Journal:  Diabetes Care       Date:  2009-09-18       Impact factor: 19.112

View more
  24 in total

1.  Experiences of Adults Using Continuous Subcutaneous Insulin Infusion: A Qualitative Study.

Authors:  Naglaa Ibrahim Mesbah; Nehad Abd-El-Raheem Taha; Zahra Nema Rahme; Faten Fawzi Sukkar; Dina Mohamed Omar
Journal:  Med Princ Pract       Date:  2019-09-27       Impact factor: 1.927

2.  Feasibility of adjacent insulin infusion and continuous glucose monitoring via the Medtronic Combo-Set.

Authors:  David N O'Neal; Sumona Adhya; Alicia Jenkins; Glenn Ward; John B Welsh; Gayane Voskanyan
Journal:  J Diabetes Sci Technol       Date:  2013-03-01

3.  From Wary Wearers to d-Embracers: Personas of Readiness to Use Diabetes Devices.

Authors:  Molly L Tanenbaum; Rebecca N Adams; Esti Iturralde; Sarah J Hanes; Regan C Barley; Diana Naranjo; Korey K Hood
Journal:  J Diabetes Sci Technol       Date:  2018-08-22

4.  Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems.

Authors:  Cosimo Scuffi
Journal:  Eur Endocrinol       Date:  2014-02-28

5.  Poor sleep quality is associated with nocturnal glycaemic variability and fear of hypoglycaemia in adults with type 1 diabetes.

Authors:  Pamela Martyn-Nemeth; Shane A Phillips; Dan Mihailescu; Sarah S Farabi; Chang Park; Rebecca Lipton; Esema Idemudia; Laurie Quinn
Journal:  J Adv Nurs       Date:  2018-07-19       Impact factor: 3.187

6.  Improved Health-Related Quality of Life in a Phase 3 Islet Transplantation Trial in Type 1 Diabetes Complicated by Severe Hypoglycemia.

Authors:  Eric D Foster; Nancy D Bridges; Irene D Feurer; Thomas L Eggerman; Lawrence G Hunsicker; Rodolfo Alejandro
Journal:  Diabetes Care       Date:  2018-03-21       Impact factor: 19.112

7.  A qualitative study exploring the expectations of people living with type 1 diabetes regarding prospective use of a hybrid closed-loop system.

Authors:  A Quintal; V Messier; R Rabasa-Lhoret; E Racine
Journal:  Diabet Med       Date:  2020-05-13       Impact factor: 4.359

Review 8.  Technology to optimize pediatric diabetes management and outcomes.

Authors:  Jessica T Markowitz; Kara R Harrington; Lori M B Laffel
Journal:  Curr Diab Rep       Date:  2013-12       Impact factor: 4.810

9.  The Effect of Retraining on Treatment Success, Quality of Life, and Metabolic Parameters in Patients with Type 1 Diabetes Using an Insulin Pump.

Authors:  Basak Ozgen Saydam; Fatma Yilmazmis; Nalan Aydin; Belgin Bektas; Simge Yilmaz; Umit Cavdar; Secil Ozisik; Baris Akinci
Journal:  Med Princ Pract       Date:  2017-04-23       Impact factor: 1.927

Review 10.  Influences on Technology Use and Efficacy in Type 1 Diabetes.

Authors:  Victoria Franklin
Journal:  J Diabetes Sci Technol       Date:  2016-05-03
View more