Literature DB >> 22131255

Amplatzer Septal Occluder to treat iatrogenic cardiac perforations.

Valérie Stolt1, Stéphane Cook, Lorenz Räber, Sunil Wani, Ali Garachamani, Rolf Vogel, Christian Seiler, Stephan Windecker, Bernhard Meier.   

Abstract

BACKGROUND: Iatrogenic free wall cardiac perforation is a rare but serious complication encountered during percutaneous cardiac procedures, which usually leads to tamponade and death. Septal occluder devices have been developed for sealing intracardiac shunts but may be also used in this emergency setting. METHODS AND
RESULTS: We report a small series of five consecutive cases of iatrogenic heart perforations that were treated with implantation of Amplatzer Septal Occluders (ASO). In the first case, iatrogenic left ventricle (LV) perforation occurred during LV biopsy and could be closed up with a 4 mm ASO. In the second case, a 4 mm ASO was used for sealing of a right atrial perforation allocated to Port-a-Cath dislodgment. The third case happened during transseptal puncture for implantation of a TandemHeart bVAD device in a patient suffering cardiogenic shock and was treated by implantation of a 5 mm ASO. The fourth patient was transferred to our facilities for percutaneous closure of an acute post-infarct VSD after anteroseptal myocardial infarction. This procedure was complicated by perforation of the posterolateral free wall and led to the deployment of 12 mm ASO. The last patient suffered from free LV wall perforation during investigation of a severe aortic stenosis and was treated by implantation of 4 mm ASO. All patients were alive after 24 hrs but the last patient died during the in-hospital stay of a right ventricular infarction complicated by multiple organ failure.
CONCLUSIONS: Percutaneous device occlusion of iatrogenic heart perforation seems to be a safe and efficient method to treat iatrogenic heart perforation. In order to perform this elegant method, it is however imperative not to prematurely withdraw the perforating catheter to maintain access to the hole for closure.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22131255     DOI: 10.1002/ccd.23027

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  9 in total

Review 1.  Management of Accidental and Iatrogenic Foreign Body Injuries to Heart- Case Series.

Authors:  Rupesh Kumar; Sandeep Singh Rana; Sanjay Kumar; Deepanwita Das; Monalisa Datta
Journal:  J Clin Diagn Res       Date:  2017-03-01

2.  Transcatheter Repair of Iatrogenic Aortic Perforation Complicating Transseptal Puncture for a Catheter Ablation of Atrial Arrhythmia.

Authors:  Ho-Ping Yu; An-Ning Feng; Shen-Kou Tsai; Ming-Chon Hsiung; Wei-Hsian Yin
Journal:  Acta Cardiol Sin       Date:  2014-09       Impact factor: 2.672

3.  COVID-19 Fears May Be Worse Than the Virus: A Case of Cardiogenic Shock Secondary to Post-Myocardial Infarction Ventricular Septum Rupture.

Authors:  Salem Gaballa; Avan AlJaf; Kashyap Patel; Jane Lindsay; Kyaw M Hlaing
Journal:  Cureus       Date:  2020-06-24

4.  Percutaneous suture based device closure of an inadvertent right ventricle perforation following pericardiocentesis.

Authors:  Rajesh Vijayvergiya; Yamasandi S Shrimanth; Ganesh Kasinadhuni; Harkant Singh; Ashish Sharma; Anish Bhargav; Navjyot Kaur
Journal:  Anatol J Cardiol       Date:  2021-11       Impact factor: 1.596

5.  Percutaneous closure of an iatrogenic right ventricular perforation with an angio-seal vascular closure device: a case report.

Authors:  J J Coughlan; Richard Szirt; Ian Pearson; John Cosgrave
Journal:  Eur Heart J Case Rep       Date:  2020-08-21

6.  Employing Amplatzer Occluder® in Cardiac Free Wall Rupture Repair: A Scoping Study.

Authors:  Pramod Theetha Kariyanna; Ashkan Tadayoni; Amog Jayarangaiah; Sudhanva Hegde; Apoorva Jayaranagaiah; Moro O Salifu; Isabel M McFarlane
Journal:  Am J Med Case Rep       Date:  2020-05-22

7.  Percutaneous closure of accidental left atrium puncture: a case report.

Authors:  Gustavo Sá Mendes; Pedro De Araújo Gonçalves; Sérgio Madeira; Paulo Oliveira
Journal:  Eur Heart J Case Rep       Date:  2020-08-23

8.  An Unusual Cause of Cardiac Tamponade during Cardiac Catheterization Study.

Authors:  Deepanwita Das; Monalisa Datta; Somnath Dey; Jyotiranjan Parida; Rupesh Kumar; Arindam Pande
Journal:  Case Rep Cardiol       Date:  2014-09-18

9.  Transthoracic delivery of large devices into the left ventricle through the right ventricle and interventricular septum: preclinical feasibility.

Authors:  Majdi Halabi; Kanishka Ratnayaka; Anthony Z Faranesh; Michael S Hansen; Israel M Barbash; Michael A Eckhaus; Joel R Wilson; Marcus Y Chen; Michael C Slack; Ozgur Kocaturk; William H Schenke; Victor J Wright; Robert J Lederman
Journal:  J Cardiovasc Magn Reson       Date:  2013-01-18       Impact factor: 5.364

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.