Literature DB >> 22130046

Clinical outcome of posterior fixation of the C1 lateral mass and C2 pedicle by polyaxial screw and rod.

Sei Woong Jeon1, Je Hoon Jeong, Gi Hoon Choi, Seung Myung Moon, Hyung Sik Hwang, Sun Kil Choi.   

Abstract

OBJECTIVE: Because of atlantoaxial complex has a unique and complicated anatomy and instability of this complex is very dangerous. We investigated the clinical results of posterior C1-C2 fixation with a polyaxial screw-rod system.
METHODS: Between July 2001 and December 2007, the authors treated 17 patients suffering from atlantoaxial deformity and instability. Atlantoaxial fusion was employed in 9 patients with upper cervical fracture and dislocation, in 6 patients with atlantoaxial subluxation, in 1 patient with pure transverse ligament injury, and in 1 patient with basilar invagination. The mean age at the time of surgery was 40.4 years (range, 15-68 years).
RESULTS: Operative times ranged from 165 to 420 min (average 306 min), and the postoperative mean VAS score was 2.4. The mean follow-up period was 26 months. Solid fusion was achieved in 15 patients at the last follow up; no injury of the vertebral artery or spinal cord and no operative mortality occurred in these cases.
CONCLUSIONS: We suggest that posterior atlantoaxial fixation using the polyaxial screw-rod system is an effective and relatively safe technique. The navigation guidance system employed during the surgical procedure was helpful methods. Future studies of the feasibility of navigation system-guided surgical procedures will be required.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22130046     DOI: 10.1016/j.clineuro.2011.11.001

Source DB:  PubMed          Journal:  Clin Neurol Neurosurg        ISSN: 0303-8467            Impact factor:   1.876


  8 in total

1.  Treatment of irreducible atlantoaxial dislocation using the transoral atlantoaxial pedicle screw technique. A report of 10 cases.

Authors:  Yi Zheng; Zeng-Hui Wu; Yi-Hong Yin; Qing-Shui Yin; Kai Zhang
Journal:  Orthopade       Date:  2016-02       Impact factor: 1.087

2.  Comparison of outcomes after atlantoaxial fusion with transarticular screws and screw-rod constructs.

Authors:  Ji Yong Kim; Chang Hyun Oh; Seung Hwan Yoon; Hyeong-Chun Park; Hyun Sung Seo
Journal:  J Korean Neurosurg Soc       Date:  2014-05-31

3.  Patient-rated outcome after atlantoaxial (C1-C2) fusion: more than a decade of evaluation of 2-year outcomes in 126 patients.

Authors:  F S Kleinstück; T F Fekete; M Loibl; D Jeszenszky; D Haschtmann; F Porchet; A F Mannion
Journal:  Eur Spine J       Date:  2021-09-03       Impact factor: 3.134

4.  Improvement in JOA Score of Treatment for Complex Atlas-Axis fractures.

Authors:  Yu Fu; Zhen-Ming Hu; Hong-Jun Huo; Xuejun Yang; Ting Hao; Wan-Lin Liu
Journal:  Pak J Med Sci       Date:  2013-05       Impact factor: 1.088

5.  The comparison of clinical outcome of fresh type II odontoid fracture treatment between anterior cannulated screws fixation and posterior instrumentation of C1-2 without fusion: a retrospective cohort study.

Authors:  Suomao Yuan; Bin Wei; Yonghao Tian; Jun Yan; Wanlong Xu; Lianlei Wang; Xinyu Liu
Journal:  J Orthop Surg Res       Date:  2018-01-08       Impact factor: 2.359

6.  Screw Placement Accuracy and Outcomes Following O-Arm-Navigated Atlantoaxial Fusion: A Feasibility Study.

Authors:  Jacob D Smith; Megan M Jack; Nicholas R Harn; Judson R Bertsch; Paul M Arnold
Journal:  Global Spine J       Date:  2015-09-21

7.  Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis.

Authors:  Parisa Azimi; Taravat Yazdanian; Edward C Benzel; Hossein Nayeb Aghaei; Shirzad Azhari; Sohrab Sadeghi; Ali Montazeri
Journal:  J Orthop Surg Res       Date:  2020-07-20       Impact factor: 2.359

8.  Fluoroscopy-Assisted C1-C2 Posterior Fixation for Atlantoaxial Instability: A Single-Center Case Series of 78 Patients.

Authors:  Charles Tatter; Alexander Fletcher-Sandersjöö; Oscar Persson; Gustav Burström; Erik Edström; Adrian Elmi-Terander
Journal:  Medicina (Kaunas)       Date:  2022-01-12       Impact factor: 2.430

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.