Literature DB >> 22127993

Noncontrast MR angiography for supraaortic arteries using inflow enhanced inversion recovery fast spin echo imaging.

Naoyuki Takei1, Mitsuharu Miyoshi, Hiroyuki Kabasawa.   

Abstract

PURPOSE: To depict supraaortic arteries using (3D fast spin echo (FSE) combined with slab selective inversion recovery for noncontrast magnetic resonance angiography (MRA) in healthy volunteers, and to investigate the property of the inflow enhanced inversion recovery FSE (IFIR-FSE) for background suppression and inflow effects.
MATERIALS AND METHODS: IFIR-FSE with no image subtraction was used to visualize the aortic arch, subclavian arteries, carotid arteries, and vertebral arteries in 10 healthy volunteers. Simulations were performed to achieve both high background suppression and inflow effects by adjusting the inversion time (TI) and wait time after data acquisition. The effect of inflow was investigated with TIs of 800, 1200, 1600, and 2000 msec. Contrast between artery and these background tissues were measured with scan protocols based on simulation results.
RESULTS: IFIR-FSE images showed good visualization of the supraaortic arteries and allowed separation of arteries from veins without image subtraction. The proposed method demonstrated that a high contrast between arteries and background tissues can be acquired with various TIs, which was in good agreement with the simulation. A TI over 1600 msec was favorable in terms of background suppression, arterial signal intensity, and inflow effects.
CONCLUSION: Inflow enhanced inversion recovery cardiac-triggered 3D FSE imaging can be used for supraaortic artery imaging without contrast agents.
Copyright © 2011 Wiley Periodicals, Inc.

Mesh:

Substances:

Year:  2011        PMID: 22127993     DOI: 10.1002/jmri.23515

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  8 in total

1.  Non-ECG-gated unenhanced MRA of the carotids: optimization and clinical feasibility.

Authors:  H Raoult; J Y Gauvrit; P Schmitt; V Le Couls; E Bannier
Journal:  Eur Radiol       Date:  2013-06-20       Impact factor: 5.315

2.  Ungated nonenhanced radial quiescent interval slice-selective (QISS) magnetic resonance angiography of the neck: Evaluation of image quality.

Authors:  Ioannis Koktzoglou; Emily A Aherne; Matthew T Walker; Joel R Meyer; Robert R Edelman
Journal:  J Magn Reson Imaging       Date:  2019-05-11       Impact factor: 4.813

3.  Accuracy of Inflow Inversion Recovery (IFIR) for Upper Abdominal Arteries Evaluation: Comparison with Contrast-Enhanced MR and CTA.

Authors:  Roberto Simonini; Pietro Andrea Bonaffini; Marco Porta; Cesare Maino; Francesco Saverio Carbone; Ludovico Dulcetta; Paolo Brambilla; Paolo Marra; Sandro Sironi
Journal:  Diagnostics (Basel)       Date:  2022-03-28

4.  Feasibility of a sub-3-minute imaging strategy for ungated quiescent interval slice-selective MRA of the extracranial carotid arteries using radial k-space sampling and deep learning-based image processing.

Authors:  Ioannis Koktzoglou; Rong Huang; Archie L Ong; Pascale J Aouad; Emily A Aherne; Robert R Edelman
Journal:  Magn Reson Med       Date:  2020-01-23       Impact factor: 4.668

Review 5.  Imaging Carotid Atherosclerosis Plaque Ulceration: Comparison of Advanced Imaging Modalities and Recent Developments.

Authors:  J Yuan; A Usman; T Das; A J Patterson; J H Gillard; M J Graves
Journal:  AJNR Am J Neuroradiol       Date:  2016-12-22       Impact factor: 3.825

6.  Hemodynamic study of unenhanced magnetic resonance angiography using spatial labeling with multiple inversion pulses sequence: a phantom study.

Authors:  Xiao Chen; Xiaoyan Meng; Di Zhu; Xianlun Zou; Yaqi Shen; Zhen Li; Jian Peng; Daoyu Hu
Journal:  Quant Imaging Med Surg       Date:  2021-05

Review 7.  MR Imaging in the 21st Century: Technical Innovation over the First Two Decades.

Authors:  Hiroyuki Kabasawa
Journal:  Magn Reson Med Sci       Date:  2021-04-16       Impact factor: 2.760

8.  Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla.

Authors:  Ioannis Koktzoglou; Matthew T Walker; Joel R Meyer; Ian G Murphy; Robert R Edelman
Journal:  J Cardiovasc Magn Reson       Date:  2016-04-12       Impact factor: 5.364

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.