PURPOSE: Diagnosis of pneumothorax relies on clinical suspicion and chest X-ray, and is often delayed. We aimed to determine whether electrical impedance tomography (EIT) can accurately identify the presence of surgically created pneumothoraces before significant changes in clinical parameters. METHODS: Six anesthetized and muscle-relaxed piglets with surfactant-depleted lungs were studied. Following chest drain insertion into the right ventral chest, 10-20 ml aliquots of air were instilled into the pleural space to a maximum volume of 200 ml. The pneumothorax was drained by attaching a Heimlich valve to the chest drain. At each instillation and after draining the pneumothorax, global and regional end-expiratory intra-thoracic volumes (EEV) were measured using respiratory inductive plethysmography (RIP) and EIT concurrently with [Formula: see text], heart rate and blood pressure. RESULTS: A significantly greater change in both global EEV(RIP) and EEV within the right ventral quadrant was seen at all volume instillations, from as little as 10 ml, compared with all other quadrants. There was no difference in EEV within the left ventral and both dorsal quadrants. Sp(O)(2) fell below 90% at 100 ml instillation. Tachycardia occurred at 140 ml instillation. EIT identified a 60% resolution of pneumothoraces within 60 s of attachment of the Heimlich valve. CONCLUSIONS: EIT accurately detects very small pneumothoraces before physiological parameters change.
PURPOSE: Diagnosis of pneumothorax relies on clinical suspicion and chest X-ray, and is often delayed. We aimed to determine whether electrical impedance tomography (EIT) can accurately identify the presence of surgically created pneumothoraces before significant changes in clinical parameters. METHODS: Six anesthetized and muscle-relaxed piglets with surfactant-depleted lungs were studied. Following chest drain insertion into the right ventral chest, 10-20 ml aliquots of air were instilled into the pleural space to a maximum volume of 200 ml. The pneumothorax was drained by attaching a Heimlich valve to the chest drain. At each instillation and after draining the pneumothorax, global and regional end-expiratory intra-thoracic volumes (EEV) were measured using respiratory inductive plethysmography (RIP) and EIT concurrently with [Formula: see text], heart rate and blood pressure. RESULTS: A significantly greater change in both global EEV(RIP) and EEV within the right ventral quadrant was seen at all volume instillations, from as little as 10 ml, compared with all other quadrants. There was no difference in EEV within the left ventral and both dorsal quadrants. Sp(O)(2) fell below 90% at 100 ml instillation. Tachycardia occurred at 140 ml instillation. EIT identified a 60% resolution of pneumothoraces within 60 s of attachment of the Heimlich valve. CONCLUSIONS: EIT accurately detects very small pneumothoraces before physiological parameters change.
Authors: Mario Augusto Rojas; Juan Manuel Lozano; Maria Ximena Rojas; Matthew Laughon; Carl Lewis Bose; Martin Alonso Rondon; Laura Charry; Jaime Alberto Bastidas; Luis Alfonso Perez; Catherine Rojas; Oscar Ovalle; Luz Astrid Celis; Jorge Garcia-Harker; Martha Lucia Jaramillo Journal: Pediatrics Date: 2009-01 Impact factor: 7.124
Authors: David G Tingay; Graeme R Polglase; Risha Bhatia; Clare A Berry; Robert J Kopotic; Clinton P Kopotic; Yong Song; Edgardo Szyld; Alan H Jobe; J Jane Pillow Journal: J Appl Physiol (1985) Date: 2015-01-29
Authors: Ilaria Milesi; David G Tingay; Emanuela Zannin; Federico Bianco; Paolo Tagliabue; Fabio Mosca; Anna Lavizzari; Maria Luisa Ventura; C Elroy Zonneveld; Elizabeth J Perkins; Don Black; Magdy Sourial; Raffaele L Dellacá Journal: Pediatr Res Date: 2016-03-08 Impact factor: 3.756
Authors: Natalie Batey; Caroline Henry; Shalabh Garg; Michael Wagner; Atul Malhotra; Michel Valstar; Thomas Smith; Don Sharkey Journal: Pediatr Res Date: 2022-03-03 Impact factor: 3.756
Authors: Dan Waisman; Anna Faingersh; Carmit Levy; Ifat Colman-Klotzman; Avi Rotschild; Oscar Lichtenstein; Amir Landesberg Journal: Intensive Care Med Date: 2012-11-21 Impact factor: 17.440
Authors: Inéz Frerichs; Marcelo B P Amato; Anton H van Kaam; David G Tingay; Zhanqi Zhao; Bartłomiej Grychtol; Marc Bodenstein; Hervé Gagnon; Stephan H Böhm; Eckhard Teschner; Ola Stenqvist; Tommaso Mauri; Vinicius Torsani; Luigi Camporota; Andreas Schibler; Gerhard K Wolf; Diederik Gommers; Steffen Leonhardt; Andy Adler Journal: Thorax Date: 2016-09-05 Impact factor: 9.139
Authors: Felix Girrbach; Tobias Landeck; Dominic Schneider; Stefan U Reske; Gunther Hempel; Sören Hammermüller; Udo Gottschaldt; Peter Salz; Katharina Noreikat; Sebastian N Stehr; Hermann Wrigge; Andreas W Reske Journal: PLoS One Date: 2020-01-10 Impact factor: 3.240
Authors: Massimo Antonelli; Marc Bonten; Maurizio Cecconi; Jean Chastre; Giuseppe Citerio; Giorgio Conti; J R Curtis; Goran Hedenstierna; Michael Joannidis; Duncan Macrae; Salvatore M Maggiore; Jordi Mancebo; Alexandre Mebazaa; Jean-Charles Preiser; Patricia Rocco; Jean-François Timsit; Jan Wernerman; Haibo Zhang Journal: Intensive Care Med Date: 2013-01-22 Impact factor: 17.440
Authors: Graeme R Polglase; David G Tingay; Risha Bhatia; Clare A Berry; Robert J Kopotic; Clinton P Kopotic; Yong Song; Edgardo Szyld; Alan H Jobe; Jane J Pillow Journal: BMC Pediatr Date: 2014-02-15 Impact factor: 2.125