Literature DB >> 22112101

In vivo intracardiac optical coherence tomography imaging through percutaneous access: toward image-guided radio-frequency ablation.

Hui Wang, Wei Kang, Thomas Carrigan, Austin Bishop, Noah Rosenthal, Mauricio Arruda, Andrew M Rollins.   

Abstract

Complete catheter-tissue contact and permanent tissue destruction are essential for efficient radio-frequency ablation (RFA) during cardiac arrhythmia treatment. Current methods of monitoring lesion formation are indirect and unreliable. The purpose of this study is to evaluate the feasibility of using optical coherence tomography (OCT) catheter to image endocardial wall in actively beating hearts through percutaneous access. We reported the first in vivo intracardiac OCT imaging through percutaneous access with a thin and flexible OCT catheter. This is a critical step toward image-guided RFA in a clinical setting. A cone-scanning forward-viewing OCT catheter was advanced into beating hearts through percutaneous access in four swine. The OCT catheter was steered by an introducer to touch the endocardial wall. We are able to acquire high quality OCT images in beating hearts, observe the polarization-related artifacts induced by the birefringence of myocardium, and readily evaluate catheter-tissue contact. The observations indicate that OCT could be a promising technique for in vivo guidance of RFA.

Entities:  

Mesh:

Year:  2011        PMID: 22112101      PMCID: PMC3230642          DOI: 10.1117/1.3656966

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  7 in total

1.  NASPE Plenary Lecture 2001. Catheter ablation: a personal perspective.

Authors:  M M Scheinman
Journal:  J Cardiovasc Electrophysiol       Date:  2001-09

2.  Real-time monitoring of cardiac radio-frequency ablation lesion formation using an optical coherence tomography forward-imaging catheter.

Authors:  Christine P Fleming; Hui Wang; Kara J Quan; Andrew M Rollins
Journal:  J Biomed Opt       Date:  2010 May-Jun       Impact factor: 3.170

3.  RF catheter ablation: Lessons on lesions.

Authors:  Fred H M Wittkampf; Hiroshi Nakagawa
Journal:  Pacing Clin Electrophysiol       Date:  2006-11       Impact factor: 1.976

4.  Two-dimensional scanning realized by an asymmetry fiber cantilever driven by single piezo bender actuator for optical coherence tomography.

Authors:  Tong Wu; Zhihua Ding; Kai Wang; Minghui Chen; Chuan Wang
Journal:  Opt Express       Date:  2009-08-03       Impact factor: 3.894

5.  Electrostatic forward-viewing scanning probe for Doppler optical coherence tomography using a dissipative polymer catheter.

Authors:  Nigel R Munce; Adrian Mariampillai; Beau A Standish; Mihaela Pop; Kevan J Anderson; George Y Liu; Tim Luk; Brian K Courtney; Graham A Wright; I Alex Vitkin; Victor X D Yang
Journal:  Opt Lett       Date:  2008-04-01       Impact factor: 3.776

6.  In vitro characterization of cardiac radiofrequency ablation lesions using optical coherence tomography.

Authors:  Christine P Fleming; Kara J Quan; Hui Wang; Guy Amit; Andrew M Rollins
Journal:  Opt Express       Date:  2010-02-01       Impact factor: 3.894

Review 7.  Ablation therapy for cardiac arrhythmias.

Authors:  W G Stevenson; K E Ellison; D C Lefroy; P L Friedman
Journal:  Am J Cardiol       Date:  1997-10-23       Impact factor: 2.778

  7 in total
  16 in total

1.  Novel catheter enabling simultaneous radiofrequency ablation and optical coherence reflectometry.

Authors:  D Herranz; Juan Lloret; Santiago Jiménez-Valero; J L Rubio-Guivernau; Eduardo Margallo-Balbás
Journal:  Biomed Opt Express       Date:  2015-08-07       Impact factor: 3.732

2.  Extracting three-dimensional orientation and tractography of myofibers using optical coherence tomography.

Authors:  Yu Gan; Christine P Fleming
Journal:  Biomed Opt Express       Date:  2013-09-13       Impact factor: 3.732

3.  Miniature forward-viewing common-path OCT probe for imaging the renal pelvis.

Authors:  Xiaoyong Fu; Dhruti Patel; Hui Zhu; Gregory MacLennan; Yves T Wang; Michael W Jenkins; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2015-03-06       Impact factor: 3.732

4.  Near-infrared spectroscopy integrated catheter for characterization of myocardial tissues: preliminary demonstrations to radiofrequency ablation therapy for atrial fibrillation.

Authors:  Rajinder P Singh-Moon; Charles C Marboe; Christine P Hendon
Journal:  Biomed Opt Express       Date:  2015-06-12       Impact factor: 3.732

5.  Integrated RFA/PSOCT catheter for real-time guidance of cardiac radio-frequency ablation.

Authors:  Xiaowei Zhao; Xiaoyong Fu; Colin Blumenthal; Yves T Wang; Michael W Jenkins; Christopher Snyder; Mauricio Arruda; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2018-11-20       Impact factor: 3.732

6.  Diffractive catheter for ultrahigh-resolution spectral-domain volumetric OCT imaging.

Authors:  Jiefeng Xi; Anqi Zhang; Zhenyu Liu; Wenxuan Liang; Lih Y Lin; Shaoyong Yu; Xingde Li
Journal:  Opt Lett       Date:  2014-04-01       Impact factor: 3.776

7.  Steerable OCT catheter for real-time assistance during teleoperated endoscopic treatment of colorectal cancer.

Authors:  Oscar Caravaca Mora; Philippe Zanne; Lucile Zorn; Florent Nageotte; Natalia Zulina; Sara Gravelyn; Paul Montgomery; Michel de Mathelin; Bernard Dallemagne; Michalina J Gora
Journal:  Biomed Opt Express       Date:  2020-02-03       Impact factor: 3.732

8.  Characterization of the human myocardium by optical coherence tomography.

Authors:  Yu Gan; Theresa H Lye; Charles C Marboe; Christine P Hendon
Journal:  J Biophotonics       Date:  2019-08-26       Impact factor: 3.207

9.  Balloon catheter-based radiofrequency ablation monitoring in porcine esophagus using optical coherence tomography.

Authors:  William C Y Lo; Néstor Uribe-Patarroyo; Katharina Hoebel; Kathy Beaudette; Martin Villiger; Norman S Nishioka; Benjamin J Vakoc; Brett E Bouma
Journal:  Biomed Opt Express       Date:  2019-03-28       Impact factor: 3.732

10.  Fiber-optic catheter-based polarization-sensitive OCT for radio-frequency ablation monitoring.

Authors:  Xiaoyong Fu; Zhao Wang; Hui Wang; Yves T Wang; Michael W Jenkins; Andrew M Rollins
Journal:  Opt Lett       Date:  2014-09-01       Impact factor: 3.776

View more