Literature DB >> 22111436

A comparison between Laryngeal Tube Suction II Airway and Proseal Laryngeal Mask Airway in laparascopic surgery.

K Esa1, I Azarinah, M Muhammad, M A Helmi, M Z Jaafar.   

Abstract

This was a prospective randomized study comparing the ease of insertion, haemodynamic changes, quality of airway seal, oxygenation and ventilation parameters and complications between Laryngeal Tube Suction II (LTS II) with Proseal Laryngeal Mask Airway (PLMA), both are supraglottic airway incorporated with gastric passage. Fifty-four ASA I and II patients were randomly allocated to receive either LTS II or PLMA. Both devices provided a secure airway even under conditions of elevated intra-abdominal pressure up to 17 mmHg. In this study, there were no differences concerning ease of insertion, haemodynamic changes, quality of airway seal, oxygenation and ventilation parameters and complications between LTS II and PLMA.

Entities:  

Mesh:

Year:  2011        PMID: 22111436

Source DB:  PubMed          Journal:  Med J Malaysia        ISSN: 0300-5283


  6 in total

1.  The laryngeal tube - a helpful tool for cardiopulmonary resuscitation in the dental office?

Authors:  G Keilholz; T S Mutzbauer
Journal:  Br Dent J       Date:  2015-05-08       Impact factor: 1.626

2.  Randomized crossover study assessing oropharyngeal leak pressure and fiber optic positioning : Laryngeal Mask Airway Supreme™ versus Laryngeal Tube LTS II™ size 2 in non-paralyzed anesthetized children.

Authors:  L Gasteiger; S Ofner; B Stögermüller; B Ziegler; J Brimacombe; C Keller
Journal:  Anaesthesist       Date:  2016-08       Impact factor: 1.041

Review 3.  Insertion Success of the Laryngeal Tube in Emergency Airway Management.

Authors:  Michael Bernhard; André Gries; Alexandra Ramshorn-Zimmer; Volker Wenzel; Bjoern Hossfeld
Journal:  Biomed Res Int       Date:  2016-08-24       Impact factor: 3.411

4.  Comparison of laryngeal tube suction II and proseal LMA™ in pediatric patients, undergoing elective surgery.

Authors:  Saurabh Chandrakar; Deepak Kumar Sreevastava; Sidharth Bhasin; Mridul Dhar
Journal:  Saudi J Anaesth       Date:  2017 Oct-Dec

5.  Evaluation of the optimal cuff volume and cuff pressure of the revised laryngeal tube "LTS-D" in surgical patients.

Authors:  Marc Kriege; Christian Alflen; Johannes Eisel; Thomas Ott; Tim Piepho; Ruediger R Noppens
Journal:  BMC Anesthesiol       Date:  2017-02-02       Impact factor: 2.217

6.  Comparison of Propofol and Ketamine-Propofol Mixture (Ketofol) on Laryngeal Tube-Suction II Conditions and Hemodynamics: A Randomized, Prospective, Double-Blind Trial.

Authors:  Ulku Ozgul; Zekine Begec; Kalender Karahan; Mehmet Ali Erdogan; Mustafa Said Aydogan; Cemil Colak; Mahmut Durmus; M Ozcan Ersoy
Journal:  Curr Ther Res Clin Exp       Date:  2013-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.