Literature DB >> 22108921

Avoiding the clamp during off-pump coronary artery bypass reduces cerebral embolic events: results of a prospective randomized trial.

Hisham El Zayat1, John D Puskas, Scott Hwang, Vinod H Thourani, Omar M Lattouf, Patrick Kilgo, Michael E Halkos.   

Abstract

The purpose of this study was to determine whether a clampless facilitating device (CFD) to perform proximal aortocoronary anastomoses would result in a lower incidence of cerebral embolic events compared with a partial clamping strategy during off-pump coronary artery bypass (OPCAB). After epiaortic ultrasound confirmed the mild aortic disease (Grades I and II), 57 patients were randomly assigned to have proximal anastomoses using a partial-occluding clamp (CL, n = 28) or a CFD [Heartstring (HS), n = 29] (Maquet Cardiovascular LLC, San Jose, CA). Solid and gaseous emboli in the middle cerebral arteries were detected using transcranial Doppler ultrasonography. The mean number of proximal anastomoses was similar between groups 1.93 ± 0.72 (CL) and 1.72 ± 0.70 (HS) (P = 0.28). The mean number of gaseous plus solid emboli was greater in the CL group than the HS group (90.0 ± 64.0 vs. 50.8 ± 36.6, P = 0.01). Emboli were fewest in patients undergoing HS anastomoses using the suction device. The number of intraoperative cerebral emboli was proportional to the number of proximal anastomoses in the HS groups, but independent of the number of proximal anastomoses in the CL groups. Among patients with a low burden of aortic atherosclerosis, partial clamping of the ascending aorta during OPCAB was associated with more cerebral embolic events compared with an anastomosis with a CFD.

Entities:  

Mesh:

Year:  2011        PMID: 22108921      PMCID: PMC3420297          DOI: 10.1093/icvts/ivr004

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  12 in total

1.  The St Jude Medical symmetry aortic connector system for proximal vein graft anastomoses in coronary artery bypass grafting.

Authors:  Friedrich S Eckstein; Luis F Bonilla; Lars Englberger; Franz F Immer; Todd A Berg; Jürg Schmidli; Thierry P Carrel
Journal:  J Thorac Cardiovasc Surg       Date:  2002-04       Impact factor: 5.209

2.  Protecting the brain in coronary artery bypass graft surgery.

Authors:  Daniel B Mark; Mark F Newman
Journal:  JAMA       Date:  2002-03-20       Impact factor: 56.272

3.  The HEARTSTRING proximal seal system is a possible source of atheroembolism.

Authors:  Shinji Kanemitsu; Keizo Tanaka; Hitoshi Suzuki; Toshiya Tokui; Toshihiko Kinoshita
Journal:  Circ J       Date:  2006-05       Impact factor: 2.993

4.  Results with the Heartstring anastomotic device in patients with diseased ascending aorta.

Authors:  Fausto Biancari; Martti Mosorin; Jarmo Lahtinen; Jouni Heikkinen; Elsi Rasinaho; Vesa Anttila; Martti Lepojärvi; Tatu Juvonen
Journal:  Scand Cardiovasc J       Date:  2006-08       Impact factor: 1.589

5.  Stroke after coronary artery operation: incidence, correlates, outcome, and cost.

Authors:  J D Puskas; A D Winston; C E Wright; J P Gott; W M Brown; J M Craver; E L Jones; R A Guyton; W S Weintraub
Journal:  Ann Thorac Surg       Date:  2000-04       Impact factor: 4.330

6.  Adverse cerebral outcomes after coronary bypass surgery. Multicenter Study of Perioperative Ischemia Research Group and the Ischemia Research and Education Foundation Investigators.

Authors:  G W Roach; M Kanchuger; C M Mangano; M Newman; N Nussmeier; R Wolman; A Aggarwal; K Marschall; S H Graham; C Ley
Journal:  N Engl J Med       Date:  1996-12-19       Impact factor: 91.245

7.  Assessment of an aortosaphenous vein graft anastomotic device in coronary surgery: clinical experience and early angiographic results.

Authors:  Carlo Antona; Roberto Scrofani; Massimo Lemma; Paolo Vanelli; Andrea Mangini; Paolo Danna; Guido Gelpi
Journal:  Ann Thorac Surg       Date:  2002-12       Impact factor: 4.330

8.  Combined use of off-pump techniques and a sutureless proximal aortic anastomotic device reduces cerebral microemboli generation during coronary artery bypass grafting.

Authors:  John E Scarborough; William White; Frantz E Derilus; Joseph P Mathew; Mark F Newman; Kevin P Landolfo
Journal:  J Thorac Cardiovasc Surg       Date:  2003-11       Impact factor: 5.209

9.  Efficacy of intraoperative epiaortic ultrasound scanning for preventing stroke after coronary artery bypass surgery.

Authors:  Atsushi Yamaguchi; Hideo Adachi; Masashi Tanaka; Takashi Ino
Journal:  Ann Thorac Cardiovasc Surg       Date:  2009-04       Impact factor: 1.520

10.  Aortic atherosclerotic plaques as a source of systemic embolism.

Authors:  M Khatibzadeh; R Mitusch; U Stierle; B Gromoll; A Sheikhzadeh
Journal:  J Am Coll Cardiol       Date:  1996-03-01       Impact factor: 24.094

View more
  5 in total

1.  Operative strategies to reduce cerebral embolic events during on- and off-pump coronary artery bypass surgery: A stratified, prospective randomized trial.

Authors:  Michael E Halkos; Aaron Anderson; Jose Nilo G Binongo; Anthony Stringer; Yi Lasanajak; Vinod H Thourani; Omar M Lattouf; Robert A Guyton; Kim T Baio; Eric Sarin; William B Keeling; N Renee Cook; Katherine Carssow; Alexis Neill; Kathryn E Glas; John D Puskas
Journal:  J Thorac Cardiovasc Surg       Date:  2017-06-16       Impact factor: 5.209

2.  Trends in aortic clamp use during coronary artery bypass surgery: effect of aortic clamping strategies on neurologic outcomes.

Authors:  William T Daniel; Patrick Kilgo; John D Puskas; Vinod H Thourani; Omar M Lattouf; Robert A Guyton; Michael E Halkos
Journal:  J Thorac Cardiovasc Surg       Date:  2013-03-08       Impact factor: 5.209

3.  SYNTAX score effect on electroencephalography power dynamics in patients undergoing on-pump coronary artery bypass grafting.

Authors:  Irina V Tarasova; Roman S Tarasov; Olga A Trubnikova; Olga L Barbarash; Leonid S Barbarash
Journal:  BMC Neurosci       Date:  2013-09-06       Impact factor: 3.288

Review 4.  Cerebrovascular Events After No-Touch Off-Pump Coronary Artery Bypass Grafting, Conventional Side-Clamp Off-Pump Coronary Artery Bypass, and Proximal Anastomotic Devices: A Meta-Analysis.

Authors:  Wojciech Pawliszak; Mariusz Kowalewski; Giuseppe Maria Raffa; Pietro Giorgio Malvindi; Magdalena Ewa Kowalkowska; Krzysztof Aleksander Szwed; Alina Borkowska; Janusz Kowalewski; Lech Anisimowicz
Journal:  J Am Heart Assoc       Date:  2016-02-18       Impact factor: 5.501

Review 5.  A Protocol for Diagnosis and Management of Aortic Atherosclerosis in Cardiac Surgery Patients.

Authors:  Wouter W Jansen Klomp; George J Brandon Bravo Bruinsma; Arnoud W J Van 't Hof; Jan G Grandjean; Arno P Nierich
Journal:  Int J Vasc Med       Date:  2017-08-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.