Results with the Heartstring anastomotic device in patients with diseased ascending aorta.

Fausto Biancari1, Martti Mosorin, Jarmo Lahtinen, Jouni Heikkinen, Elsi Rasinaho, Vesa Anttila, Martti Lepojärvi, Tatu Juvonen.   

Abstract

BACKGROUND: Avoidance of manipulation of diseased ascending aorta has been shown to be associated with a reduced risk of postoperative stroke after off-pump coronary artery bypass surgery (OPCAB). The use of the Heartstring device (Guidant, Indianapolis, USA) to accomplish a proximal aortic anastomosis without aortic clamping has been suggested in such patients. PATIENTS AND METHODS: From April 2004 to December 2005, proximal aortic anastomoses have been accomplished employing the Heartstring device in 19 patients with calcified ascending aorta who underwent OPCAB. The diagnosis of diseased ascending aorta was made intraoperatively by epiaortic ultrasound scanning.
RESULTS: Eighteen vein grafts and three radial artery grafts have been successfully anastomosed to the ascending aorta by employing the Heartstring device. Breaking of eight seals occurred during insertion. One patient (5.2%) had stroke two days after urgent OPCAB.
CONCLUSION: The use of the Heartstring anastomotic device should be considered in high-risk patients with diseased ascending aorta requiring a prompt myocardial revascularization, whenever there is a place to safely insert this device into the ascending aorta.

Entities:  

Mesh:

Year:  2006        PMID: 16914416     DOI: 10.1080/14017430600849211

Source DB:  PubMed          Journal:  Scand Cardiovasc J        ISSN: 1401-7431            Impact factor:   1.589


  3 in total

1.  Avoiding the clamp during off-pump coronary artery bypass reduces cerebral embolic events: results of a prospective randomized trial.

Authors:  Hisham El Zayat; John D Puskas; Scott Hwang; Vinod H Thourani; Omar M Lattouf; Patrick Kilgo; Michael E Halkos
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-11-18

2.  Minimizing the risk of perioperative stroke by clampless off-pump bypass surgery: a retrospective observational analysis.

Authors:  Michael Hilker; Mathias Arlt; Andreas Keyser; Simon Schopka; Alexander Klose; Claudius Diez; Christof Schmid
Journal:  J Cardiothorac Surg       Date:  2010-03-25       Impact factor: 1.637

3.  Technological solutions for cardiac surgery in the elderly.

Authors:  Rony-Reuven Nir; Gil Bolotin
Journal:  Rambam Maimonides Med J       Date:  2013-07-25
  3 in total