The use of targeted neonatal echocardiography to confirm placement of peripherally inserted central catheters in neonates.

Amish Jain1, Patrick J McNamara, Eugene Ng, Afif El-Khuffash.   

Abstract

The use of plain radiographs in assessing the correct position of peripherally inserted central catheter (PICC) line tips is not always accurate. Ultrasound may be a better modality in detecting tip position and aid in line manipulation. We assessed the accuracy of plain radiographs in determining PICC line tip position compared with using targeted neonatal echocardiography (TnECHO) in a tertiary neonatal intensive care unit. Following PICC insertion, tip position was confirmed using TnECHO after the first radiograph. A 2 × 2 table was constructed to compare the two modalities' ability to detect line position. A total of 22 infants were included in the study with a gestation of 26.5 weeks (25.4 to 28.8) and birth weight of 833 g (710 to 1930). Concordance between radiographs and TnECHO for PICC line tip position occurred in 13 infants (59%). Sensitivity of radiographs in determining malposition was 64% with a specificity of 55%. Three infants were incorrectly identified to have deep lines and two infants were incorrectly identified to have short lines. In nine infants (41%), a second radiograph was avoided following line manipulation using TnECHO. TnECHO is a useful tool in identifying tip position, performing real-time manipulation, and minimizing exposure to further radiographs. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2011        PMID: 22105438     DOI: 10.1055/s-0031-1295649

Source DB:  PubMed          Journal:  Am J Perinatol        ISSN: 0735-1631            Impact factor:   1.862


  11 in total

1.  The superiority of point of care ultrasound in localizing central venous line tip position over time.

Authors:  Nahla Zaghloul; Laura Watkins; Jennie Choi-Rosen; Shahana Perveen; Dalibor Kurepa
Journal:  Eur J Pediatr       Date:  2018-10-29       Impact factor: 3.183

2.  Use of real-time ultrasound for locating tip position in neonates undergoing peripherally inserted central catheter insertion: A pilot study.

Authors:  Nagsen Telang; Deepak Sharma; Oleti Tejo Pratap; Hemasree Kandraju; Srinivas Murki
Journal:  Indian J Med Res       Date:  2017-03       Impact factor: 2.375

Review 3.  [Avoidance of complications when dealing with central venous catheters in the treatment of children].

Authors:  D Aprili; T O Erb
Journal:  Anaesthesist       Date:  2017-04       Impact factor: 1.041

4.  Diagnostic accuracy of ultrasound for localising peripherally inserted central catheter tips in infants in the neonatal intensive care unit: a systematic review and meta-analysis.

Authors:  Shauna C Doyle; Niamh M Bergin; Rena Young; Andrew England; Mark F McEntee
Journal:  Pediatr Radiol       Date:  2022-05-05

5.  Point-of-care ultrasound for neonatal central catheter positioning: impact on X-rays and line tip position accuracy.

Authors:  Serena Rossi; K Haran Jogeesvaran; Eugen Matu; Hammad Khan; Elisabetta Grande; Virginie Meau-Petit
Journal:  Eur J Pediatr       Date:  2022-02-12       Impact factor: 3.183

6.  Validation study of the accuracy of echocardiographic measurements of systemic blood flow volume in newborn infants.

Authors:  Benjamim Ficial; Anna E Finnemore; David J Cox; Kathryn M Broadhouse; Anthony N Price; Giuliana Durighel; Georgia Ekitzidou; Joseph V Hajnal; A David Edwards; Alan M Groves
Journal:  J Am Soc Echocardiogr       Date:  2013-09-26       Impact factor: 5.251

7.  Improved visualization of peripherally inserted central catheters on chest radiographs of neonates using fractional multiscale image processing.

Authors:  Rebecca A Hammon; Hannes Seuss; Matthias Hammon; Christian Grillhösl; Rafael Heiss; Martin Zeilinger; Nadine Bayerl; Pieter Vuylsteke; Friedrich Wanninger; Michael Schroth; Michael Uder; Oliver Rompel
Journal:  BMC Med Imaging       Date:  2019-01-07       Impact factor: 1.930

8.  Cardiovascular management following hypoxic-ischemic encephalopathy in North America: need for physiologic consideration.

Authors:  Regan E Giesinger; Philip T Levy; J Lauren Ruoss; Mohamed El Dib; Khorshid Mohammad; Pia Wintermark; Patrick J McNamara
Journal:  Pediatr Res       Date:  2020-10-18       Impact factor: 3.756

9.  Low cardiac output secondary to a malpositioned umbilical venous catheter: value of targeted neonatal echocardiography.

Authors:  Dany E Weisz; Wei Bing Poon; Andrew James; Patrick J McNamara
Journal:  AJP Rep       Date:  2014-03-03

Review 10.  Supraclavicular Approach to Ultrasound-Guided Brachiocephalic Vein Cannulation in Children and Neonates.

Authors:  Zied Merchaoui; Ulrik Lausten-Thomsen; Florence Pierre; Maher Ben Laiba; Nolwenn Le Saché; Pierre Tissieres
Journal:  Front Pediatr       Date:  2017-10-05       Impact factor: 3.418

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.