Literature DB >> 22104187

Evaluation of 3 different rapid automated systems for diagnosis of urinary tract infections.

Matthias Marschal1, Matthias Wienke, Steffen Hoering, Ingo B Autenrieth, Julia-Stefanie Frick.   

Abstract

Urinary tract infections (UTI) are one of the most common infections in both hospitalised and ambulant patients. Rapid diagnostic of UTIs is necessary to provide early information about the presence of bacteria and the indication to administer an antibiotic therapy. Here we report on a study comparing 3 different rapid automated systems with the semiquantitative plate culture reference method in a university hospital with a highly complex patient population. In total, 2230 urine samples were consecutively tested using the UroQuick (Alifax), the BACSYS-40i (Sysmex), and the UF-1000i (Sysmex) system. In comparison to the results obtained by culture techniques, the automated systems showed a sensitivity of 73.0-80.9% and a specificity ranging between 61.8% and 92.8%. Additionally, sensitivity and specificity for the most common UTI-causing microorganisms were analysed and showed that sensitivity and specificity correlate with the colony forming units of microorganisms in the urine, with a sensitivity of nearly 90% for Gram-negative rods, typical for community acquired UTIs, but a very low sensitivity for Gram-positive bacteria and yeasts. This led us to the conclusion that the currently available automated systems might be rather helpful to analyse a typical UTI in an ambulant patient population but not for rapid diagnosis of UTIs in a complex population of hospitalized patients.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22104187     DOI: 10.1016/j.diagmicrobio.2011.10.001

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  9 in total

1.  Selective detection of bacteria in urine with a long-range surface plasmon waveguide biosensor.

Authors:  Paul Béland; Oleksiy Krupin; Pierre Berini
Journal:  Biomed Opt Express       Date:  2015-07-16       Impact factor: 3.732

2.  Evaluation of the Alfred 60/AST device as a screening test for urinary tract infections.

Authors:  Sophie Lahanas; George Stathopoulos; Raymond C Chan; Sebastiaan J van Hal
Journal:  J Clin Microbiol       Date:  2013-07-24       Impact factor: 5.948

3.  Comparative evaluation of Vitek 2 identification and susceptibility testing of urinary tract pathogens directly and isolated from chromogenic media.

Authors:  M J Munoz-Dávila; M Roig; G Yagüe; A Blázquez; C Salvador; M Segovia
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-01-12       Impact factor: 3.267

4.  Flow cytometry analysis using sysmex UF-1000i classifies uropathogens based on bacterial, leukocyte, and erythrocyte counts in urine specimens among patients with urinary tract infections.

Authors:  Tor Monsen; Patrik Rydén
Journal:  J Clin Microbiol       Date:  2014-12-03       Impact factor: 5.948

5.  A new concept and a comprehensive evaluation of SYSMEX UF-1000i  flow cytometer to identify culture-negative urine specimens in patients with UTI.

Authors:  T Monsen; P Ryden
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2017-04-06       Impact factor: 3.267

Review 6.  Automated Flow Cytometry: An Alternative to Urine Culture in a Routine Clinical Microbiology Laboratory?

Authors:  Patricia Mejuto; Mariam Luengo; Julio Díaz-Gigante
Journal:  Int J Microbiol       Date:  2017-09-27

7.  Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i® Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain.

Authors:  María I Millán-Lou; Juan M García-Lechuz; María A Ruiz-Andrés; Concepción López; María J Aldea; María J Revillo; Antonio Rezusta
Journal:  Front Med (Lausanne)       Date:  2018-04-09

8.  [URISCAM project: Multicenter evaluation of the UF-Series cytometer in the urinary tract infections screening].

Authors:  M M Jarabo; M A Asencio; R Carranza; O Herráez; M Huertas; A Arias-Arias; O Redondo; M A Galán; M S Illescas; P Zamarrón; S Solís; S Jiménez-Alvarez
Journal:  Rev Esp Quimioter       Date:  2018-01-29       Impact factor: 1.553

9.  Direct identification and susceptibility testing of Gram-negative bacilli from turbid urine samples using VITEK2.

Authors:  Neelima Angaali; Laxmi Vemu; Chavali Padmasri; Neeraja Mamidi; Vijay Dharma Teja
Journal:  J Lab Physicians       Date:  2018 Jul-Sep
  9 in total