Ultrasound safety in early pregnancy: reduced energy setting does not compromise obstetric Doppler measurements.

R K Sande1, K Matre, G E Eide, T Kiserud.   

Abstract

OBJECTIVES: We hypothesized that first-trimester Doppler ultrasonography can be carried out at lower output energies than the currently advocated limits without compromising clinically important information.
METHODS: We recruited 42 pregnant women for an ultrasound examination at 12 weeks' gestation. Twenty-one women were examined with a transvaginal transducer, the rest with a transabdominal transducer. We used pulsed Doppler to measure pulsatility index (PI) and peak systolic velocity (PSV) in five clinically relevant fetal and maternal blood vessels. The energy indicator thermal index for bone (TIb) was set at 1.0, 0.5 and 0.1. Each measurement was repeated three times. A mixed linear regression model accounting for correlation between measurements was used to assess the effect of different TIb levels and transducers.
RESULTS: We were able to visualize the vessels by color Doppler and measure PI and PSV in all vessels at all energy levels in all the participants with the exception of the ductus venosus in two participants, yielding 1872 recordings for statistical analysis. A reduction in TIb from 1.0 to 0.5 and 0.1 had no effect on the PI or PSV values, nor was there any trend towards higher parameter variance with decreasing TIb. There was no difference between measured values of PI and PSV between the transducers, but the transabdominal technique was associated with a greater parameter variance.
CONCLUSION: Reliable first-trimester Doppler data can be obtained with output energy reduced to a TIb of 0.5 or 0.1.
Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 22102527     DOI: 10.1002/uog.10148

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  3 in total

1.  Do current Philips ultrasound systems exceed the recommended safety limits during routine prenatal ultrasounds?

Authors:  Qi Hao Ong; Martin Necas; Karen Lissington
Journal:  Australas J Ultrasound Med       Date:  2019-06-27

2.  In vitro characterisation of ultrasound-induced heating effects in the mother and fetus: A clinical perspective.

Authors:  Stephanie F Smith; Piero Miloro; Richard Axell; Gail Ter Haar; Christoph Lees
Journal:  Ultrasound       Date:  2020-09-14

3.  First-trimester ultrasound detection of fetal heart anomalies: systematic review and meta-analysis.

Authors:  J N Karim; E Bradburn; N Roberts; A T Papageorghiou
Journal:  Ultrasound Obstet Gynecol       Date:  2022-01       Impact factor: 8.678

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.