Literature DB >> 22100102

Computational comparison of the bending behavior of aortic stent-grafts.

Nicolas Demanget1, Stéphane Avril, Pierre Badel, Laurent Orgéas, Christian Geindreau, Jean-Noël Albertini, Jean-Pierre Favre.   

Abstract

Secondary interventions after endovascular repair of abdominal aortic aneurysms are frequent because stent-graft (SG) related complications may occur (mainly endoleak and SG thrombosis). Complications have been related to insufficient SG flexibility, especially when devices are deployed in tortuous arteries. Little is known on the relationship between SG design and flexibility. Therefore, the aim of this study was to simulate numerically the bending of two manufactured SGs (Aorfix--Lombard Medical (A) and Zenith--Cook Medical Europe (Z)) using finite element analysis (FEA). Global SG behavior was studied by assessing stent spacing variation and cross-section deformation. Four criteria were defined to compare flexibility of SGs: maximal luminal reduction rate, torque required for bending, maximal membrane strains in graft and maximal Von Mises stress in stents. For angulation greater than 60°, values of these four criteria were lower with A-SG, compared to Z-SG. In conclusion, A-SG was more flexible than Z-SG according to FEA. A-SG may decrease the incidence of complications in the setting of tortuous aorto-iliac aneurysms. Our numerical model could be used to assess flexibility of further manufactured as well as newly designed SGs.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22100102     DOI: 10.1016/j.jmbbm.2011.09.006

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  9 in total

Review 1.  A critical appraisal of endovascular stent-grafts in the management of abdominal aortic aneurysms.

Authors:  Nikolaos Schoretsanitis; Efstratios Georgakarakos; Christos Argyriou; Kiriakos Ktenidis; George S Georgiadis
Journal:  Radiol Med       Date:  2017-01-21       Impact factor: 3.469

2.  Effects of longitudinal pre-stretch on the mechanics of human aorta before and after thoracic endovascular aortic repair (TEVAR) in trauma patients.

Authors:  Anastasia Desyatova; Jason MacTaggart; Alexey Kamenskiy
Journal:  Biomech Model Mechanobiol       Date:  2019-09-05

3.  A Computational Framework Examining the Mechanical Behaviour of Bare and Polymer-Covered Self-Expanding Laser-Cut Stents.

Authors:  Ciara G McKenna; Ted J Vaughan
Journal:  Cardiovasc Eng Technol       Date:  2021-11-30       Impact factor: 2.305

4.  Suture Line Dehiscence after Endovascular Aneurysm Repair in a Patient with Marfan Syndrome.

Authors:  Hirofumi Kasahara; Norimasa Haijima; Takashi Hachiya
Journal:  Ann Vasc Dis       Date:  2017-06-25

5.  A new approach for the pre-clinical optimization of a spatial configuration of bifurcated endovascular prosthesis placed in abdominal aortic aneurysms.

Authors:  Andrzej Polanczyk; Aleksandra Piechota-Polanczyk; Ludomir Stefańczyk
Journal:  PLoS One       Date:  2017-08-09       Impact factor: 3.240

6.  An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents.

Authors:  Jing Lin; Robert Guidoin; Jia Du; Lu Wang; Graeham Douglas; Danjie Zhu; Mark Nutley; Lygia Perron; Ze Zhang; Yvan Douville
Journal:  Materials (Basel)       Date:  2016-02-16       Impact factor: 3.623

Review 7.  A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications.

Authors:  Mehdi Jafary-Zadeh; Gideon Praveen Kumar; Paulo Sergio Branicio; Mohsen Seifi; John J Lewandowski; Fangsen Cui
Journal:  J Funct Biomater       Date:  2018-02-27

8.  Evaluation of a New Approach for Modeling Full Ring Stent Bundles with the Inclusion of Manufacturing Strains.

Authors:  Faidon Kyriakou; David Bow; William Dempster; Robbie Brodie; David Nash
Journal:  Ann Biomed Eng       Date:  2019-07-17       Impact factor: 3.934

9.  Evaluation and Verification of Fast Computational Simulations of Stent-Graft Deployment in Endovascular Aneurysmal Repair.

Authors:  Aymeric Pionteck; Baptiste Pierrat; Sébastien Gorges; Jean-Noël Albertini; Stéphane Avril
Journal:  Front Med Technol       Date:  2021-07-20
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.