Literature DB >> 22098904

Neutron diffraction residual strain measurements in nanostructured hydroxyapatite coatings for orthopaedic implants.

R Ahmed1, N H Faisal, A M Paradowska, M E Fitzpatrick, K A Khor.   

Abstract

The failure of an orthopaedic implant can be initiated by residual strain inherent to the hydroxyapatite coating (HAC). Knowledge of the through-thickness residual strain profile in the thermally sprayed hydroxyapatite coating/substrate system is therefore important in the development of a new generation of orthopaedic implants. As the coating microstructure is complex, non-destructive characterization of residual strain, e.g. using neutron diffraction, provides a useful measure of through thickness strain profile without altering the stress field. This first detailed study using a neutron diffraction technique, non-destructively evaluates the through thickness strain measurement in nanostructured hydroxyapatite plasma sprayed coatings on a titanium alloy substrate (as-sprayed, heat treated, and heat treated then soaked in simulated body fluid (SBF)). The influence of crystallographic plane orientation on the residual strain measurement is shown to indicate texturing in the coating. This texturing is expected to influence both the biological and fracture response of HA coatings. Results are discussed in terms of the influence of heat-treatment and SBF on the residual stress profile for these biomedical coatings. The results show that the through thickness residual strain in all three coatings was different for different crystallographic planes but was on average tensile. It is also concluded that the heat-treatment and simulated body fluid exposure had a significant effect on the residual strain profile in the top layers of HAC.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22098904     DOI: 10.1016/j.jmbbm.2011.07.003

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  2 in total

1.  A comparison between a hinged plate and screw system and a conventional tension-band plate and screw system used for correction of an angular deformity of the lower limb: an animal study.

Authors:  Zhenkai Wu; Dahang Zhao; Li Zhao; Jianlin Liu; Hai Li; Jie Zhu; Fengcang Ma; Daniel Edward Porter
Journal:  J Orthop Surg Res       Date:  2015-05-03       Impact factor: 2.359

Review 2.  Application of Selected Biomaterials and Stem Cells in the Regeneration of Hard Dental Tissue in Paediatric Dentistry-Based on the Current Literature.

Authors:  Alina Wrzyszcz-Kowalczyk; Maciej Dobrzynski; Iwona Grzesiak-Gasek; Wojciech Zakrzewski; Monika Mysiak-Debska; Patrycja Nowak; Malgorzata Zimolag; Rafal J Wiglusz
Journal:  Nanomaterials (Basel)       Date:  2021-12-13       Impact factor: 5.076

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.