Literature DB >> 22095494

Measurements of water vapor isotope ratios with wavelength-scanned cavity ring-down spectroscopy technology: new insights and important caveats for deuterium excess measurements in tropical areas in comparison with isotope-ratio mass spectrometry.

Guillaume Tremoy1, Françoise Vimeux, Olivier Cattani, Salla Mayaki, Ide Souley, Guillaume Favreau.   

Abstract

The new infrared laser spectroscopic techniques enable us to measure the isotopic composition (δ(18)O and δ(2)H) of atmospheric water vapor. With the objective of monitoring the isotopic composition of tropical water vapor (West Africa, South America), and to discuss deuterium excess variability (d=δ(2)H - 8δ(18)O) with an accuracy similar to measurements arising from isotope-ratio mass spectrometry (IRMS), we have conducted a number of tests and calibrations using a wavelength-scanned cavity ring-down spectroscopy (WS-CRDS) technique. We focus in this paper on four main aspects regarding (1) the tubing material, (2) the humidity calibration of the instrument, (3) the water vapor concentration effects on δ, and (4) the isotopic calibration of the instrument. First, we show that Synflex tubing strongly affects δ(2)H measurements and thus leads to unusable d values. Second, we show that the mixing ratio as measured by WS-CRDS has to be calibrated versus atmospheric mixing ratio measurements and we also suggest possible non-linear effects over the whole mixing ratio range (~2 to 20 g/kg). Third, we show that significant non-linear effects are induced by water vapor concentration variations on δ measurements, especially for mixing ratios lower than ~5 g/kg. This effect induces a 5 to 10‰ error in deuterium excess and is instrument-dependent. Finally, we show that an isotopic calibration (comparison between measured and true values of isotopic water standards) is needed to avoid errors on deuterium excess that can attain ~10‰.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Year:  2011        PMID: 22095494     DOI: 10.1002/rcm.5252

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  The doubly labeled water method produces highly reproducible longitudinal results in nutrition studies.

Authors:  William W Wong; Susan B Roberts; Susan B Racette; Sai Krupa Das; Leanne M Redman; James Rochon; Manjushri V Bhapkar; Lucinda L Clarke; William E Kraus
Journal:  J Nutr       Date:  2014-02-12       Impact factor: 4.798

2.  Stable isotopes in the atmospheric marine boundary layer water vapour over the Atlantic Ocean, 2012-2015.

Authors:  Marion Benetti; Hans Christian Steen-Larsen; Gilles Reverdin; Árný Erla Sveinbjörnsdóttir; Giovanni Aloisi; Max B Berkelhammer; Bernard Bourlès; Denis Bourras; Gaëlle de Coetlogon; Ann Cosgrove; Anne-Katrine Faber; Jacques Grelet; Steffen Bo Hansen; Rod Johnson; Hervé Legoff; Nicolas Martin; Andrew J Peters; Trevor James Popp; Thierry Reynaud; Malte Winther
Journal:  Sci Data       Date:  2017-01-17       Impact factor: 6.444

3.  Resolving the controls of water vapour isotopes in the Atlantic sector.

Authors:  Jean-Louis Bonne; Melanie Behrens; Hanno Meyer; Sepp Kipfstuhl; Benjamin Rabe; Lutz Schönicke; Hans Christian Steen-Larsen; Martin Werner
Journal:  Nat Commun       Date:  2019-04-09       Impact factor: 14.919