Literature DB >> 22095423

Diagnostic accuracy of second-generation dual-source computed tomography coronary angiography with iterative reconstructions: a real-world experience.

E Maffei1, C Martini, A Rossi, N Mollet, C Lario, M Castiglione Morelli, A Clemente, G Gentile, T Arcadi, S Seitun, O Catalano, A Aldrovandi, F Cademartiri.   

Abstract

PURPOSE: The authors evaluated the diagnostic accuracy of second-generation dual-source (DSCT) computed tomography coronary angiography (CTCA) with iterative reconstructions for detecting obstructive coronary artery disease (CAD).
MATERIALS AND METHODS: Between June 2010 and February 2011, we enrolled 160 patients (85 men; mean age 61.2±11.6 years) with suspected CAD. All patients underwent CTCA and conventional coronary angiography (CCA). For the CTCA scan (Definition Flash, Siemens), we use prospective tube current modulation and 70-100 ml of iodinated contrast material (Iomeprol 400 mgI/ ml, Bracco). Data sets were reconstructed with iterative reconstruction algorithm (IRIS, Siemens). CTCA and CCA reports were used to evaluate accuracy using the threshold for significant stenosis at ≥50% and ≥70%, respectively.
RESULTS: No patient was excluded from the analysis. Heart rate was 64.3±11.9 bpm and radiation dose was 7.2±2.1 mSv. Disease prevalence was 30% (48/160). Sensitivity, specificity and positive and negative predictive values of CTCA in detecting significant stenosis were 90.1%, 93.3%, 53.2% and 99.1% (per segment), 97.5%, 91.2%, 61.4% and 99.6% (per vessel) and 100%, 83%, 71.6% and 100% (per patient), respectively. Positive and negative likelihood ratios at the per-patient level were 5.89 and 0.0, respectively.
CONCLUSIONS: CTCA with second-generation DSCT in the real clinical world shows a diagnostic performance comparable with previously reported validation studies. The excellent negative predictive value and likelihood ratio make CTCA a first-line noninvasive method for diagnosing obstructive CAD.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22095423     DOI: 10.1007/s11547-011-0754-x

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  34 in total

1.  Coronary angiography with multi-slice computed tomography.

Authors:  K Nieman; M Oudkerk; B J Rensing; P van Ooijen; A Munne; R J van Geuns; P J de Feyter
Journal:  Lancet       Date:  2001-02-24       Impact factor: 79.321

2.  Spiral CT-angiography with one, four, and sixteen slice scanners. Technical note.

Authors:  Filippo Cademartiri; Giacomo Luccichenti; Riccardo Marano; Koen Nieman; Nico Mollet; Pim J de Feyter; Gabriel P Krestin; Paolo Pavone; Lorenzo Bonomo
Journal:  Radiol Med       Date:  2003-10       Impact factor: 3.469

3.  ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography. A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the American Society of Nuclear Cardiology, the North American Society for Cardiovascular Imaging, the Society for Cardiovascular Angiography and Interventions, and the Society for Cardiovascular Magnetic Resonance.

Authors:  Allen J Taylor; Manuel Cerqueira; John McB Hodgson; Daniel Mark; James Min; Patrick O'Gara; Geoffrey D Rubin; Christopher M Kramer; Daniel Berman; Alan Brown; Farooq A Chaudhry; Ricardo C Cury; Milind Y Desai; Andrew J Einstein; Antoinette S Gomes; Robert Harrington; Udo Hoffmann; Rahul Khare; John Lesser; Christopher McGann; Alan Rosenberg; Robert Schwartz; Marc Shelton; Gerald W Smetana; Sidney C Smith
Journal:  J Am Coll Cardiol       Date:  2010-11-23       Impact factor: 24.094

4.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

Review 5.  Introduction to coronary imaging with 64-slice computed tomography.

Authors:  Filippo Cademartiri; Giuseppe Runza; Manuel Belgrano; Giacomo Luccichenti; Nico R Mollet; Patrizia Malagutti; Marco Silvestrini; Massimo Midiri; Maria Cova; Roberto Pozzi Mucelli; Gabriel P Krestin
Journal:  Radiol Med       Date:  2005 Jul-Aug       Impact factor: 3.469

6.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

7.  Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience.

Authors:  Stephan Achenbach; Dieter Ropers; Axel Kuettner; Thomas Flohr; Bernd Ohnesorge; Herbert Bruder; Heike Theessen; Meri Karakaya; Werner G Daniel; Werner Bautz; Willi A Kalender; Katharina Anders
Journal:  Eur J Radiol       Date:  2006-01-19       Impact factor: 3.528

8.  Diagnostic accuracy of 64-slice multislice computed tomography in the noninvasive evaluation of significant coronary artery disease.

Authors:  Joanne D Schuijf; Gabija Pundziute; J Wouter Jukema; Hildo J Lamb; Bas L van der Hoeven; Albert de Roos; Ernst E van der Wall; Jeroen J Bax
Journal:  Am J Cardiol       Date:  2006-05-19       Impact factor: 2.778

9.  Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation.

Authors:  Stephan Achenbach; Dieter Ropers; Falk-Karsten Pohle; Dorette Raaz; Johannes von Erffa; Attila Yilmaz; Gerd Muschiol; Werner G Daniel
Journal:  Eur Heart J       Date:  2005-05-27       Impact factor: 29.983

10.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

View more
  4 in total

Review 1.  Meta-analysis: diagnostic accuracy of coronary CT angiography with prospective ECG gating based on step-and-shoot, Flash and volume modes for detection of coronary artery disease.

Authors:  Linfeng Yang; Tao Zhou; Ruijie Zhang; Lin Xu; Zhaohui Peng; Juan Ding; Sen Wang; Min Li; Gang Sun
Journal:  Eur Radiol       Date:  2014-05-28       Impact factor: 5.315

Review 2.  CT Myocardial Perfusion Imaging: A New Frontier in Cardiac Imaging.

Authors:  Sara Seitun; Cecilia De Lorenzi; Filippo Cademartiri; Angelo Buscaglia; Nicole Travaglio; Manrico Balbi; Gian Paolo Bezante
Journal:  Biomed Res Int       Date:  2018-10-14       Impact factor: 3.411

Review 3.  The diagnostic performance of coronary artery angiography with 64-MSCT and post 64-MSCT: systematic review and meta-analysis.

Authors:  Min Li; Xiang-Min Du; Zhi-Tao Jin; Zhao-Hui Peng; Juan Ding; Li Li
Journal:  PLoS One       Date:  2014-01-21       Impact factor: 3.240

4.  SIRM-SIC appropriateness criteria for the use of Cardiac Computed Tomography. Part 1: Congenital heart diseases, primary prevention, risk assessment before surgery, suspected CAD in symptomatic patients, plaque and epicardial adipose tissue characterization, and functional assessment of stenosis.

Authors:  Antonio Esposito; Marco Francone; Daniele Andreini; Vitaliano Buffa; Filippo Cademartiri; Iacopo Carbone; Alberto Clemente; Andrea Igoren Guaricci; Marco Guglielmo; Ciro Indolfi; Ludovico La Grutta; Guido Ligabue; Carlo Liguori; Giuseppe Mercuro; Saima Mushtaq; Danilo Neglia; Anna Palmisano; Roberto Sciagrà; Sara Seitun; Davide Vignale; Gianluca Pontone; Nazario Carrabba
Journal:  Radiol Med       Date:  2021-06-23       Impact factor: 3.469

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.