Literature DB >> 22093013

Dimensions of buccal bone and mucosa at immediately placed implants after 7 years: a clinical and cone beam computed tomography study.

Goran I Benic1, Muizzaddin Mokti, Chun-Jung Chen, Hans-Peter Weber, Christoph H F Hämmerle, German O Gallucci.   

Abstract

OBJECTIVE: The objective of this study was to evaluate the dimensions of buccal bone and soft tissue at immediately placed implants over a 7-year period.
MATERIAL AND METHODS: Twenty-four patients, that participated in a clinical prospective study and received implants immediately placed into extraction socket, were enrolled for this study. Residual bone defects were grafted with xenogenic bone substitute and covered by means of collagen membrane. Baseline examination included measurements of full-mouth plaque and bleeding scores, width of keratinized mucosa, and dimensions of residual bone defects at the buccal aspect. Seven years after implant placement, full-mouth plaque score, full-mouth bleeding score, width of keratinized mucosa, and probing pocket depth were assessed and cone beam computed tomography images acquired. Dimensions of buccal bone and soft tissue were evaluated on the cross-sectional cone beam computed tomography reconstructions. Differences between two time-points were tested using the two-sided t-test. Correlation analysis was used to investigate the influence of baseline bone defect dimensions on the bone dimensions measured at the 7-year follow-up. RESULTS AND
CONCLUSIONS: Fourteen patients attended the follow-up examination. In five implants almost no buccal bone was detected, whereas in the remaining nine implants the buccal bone was found covering the rough implant surface. No correlation was found between initial bone defects and bone dimensions at the follow-up examination. The sites without radiographically detectable buccal bone at the 7-year control presented with 1 mm more apical mucosal level in comparison to implants with intact buccal bone.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22093013     DOI: 10.1111/j.1600-0501.2011.02253.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  16 in total

1.  Long-term stability of early implant placement with contour augmentation.

Authors:  D Buser; V Chappuis; U Kuchler; M M Bornstein; J G Wittneben; R Buser; Y Cavusoglu; U C Belser
Journal:  J Dent Res       Date:  2013-10-24       Impact factor: 6.116

2.  Assessment of metal artefact reduction around dental titanium implants in cone beam CT.

Authors:  A Parsa; N Ibrahim; B Hassan; K Syriopoulos; P van der Stelt
Journal:  Dentomaxillofac Radiol       Date:  2014-08-19       Impact factor: 2.419

3.  Volumetric and linear changes at dental implants following grafting with volume-stable three-dimensional collagen matrices or autogenous connective tissue grafts: 6-month data.

Authors:  Nadja Naenni; Stefan P Bienz; Goran I Benic; Ronald E Jung; Christoph H F Hämmerle; Daniel S Thoma
Journal:  Clin Oral Investig       Date:  2017-09-18       Impact factor: 3.573

4.  Primary bone augmentation leads to equally stable marginal tissue conditions comparing the use of xenograft blocks infused with BMP-2 and autogenous bone blocks: A 3D analysis after 3 years.

Authors:  Stefan P Bienz; Michael Payer; Jenni Hjerppe; Jürg Hüsler; Norbert Jakse; Patrick R Schmidlin; Christoph H F Hämmerle; Ronald E Jung; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2021-09-28       Impact factor: 5.021

5.  Interdisciplinary rehabilitation of a root-fractured maxillary central incisor: A 12-year follow-up case report.

Authors:  Giulio Alessandri Bonetti; Serena Incerti Parenti; Maurizio Ciocci; Luigi Checchi
Journal:  Korean J Orthod       Date:  2014-07-24       Impact factor: 1.372

6.  A 3-Year Prospective Study on a Porcine-Derived Acellular Collagen Matrix to Re-Establish Convexity at the Buccal Aspect of Single Implants in the Molar Area: A Volumetric Analysis.

Authors:  Célien Eeckhout; Eline Bouckaert; Dagmar Verleyen; Thomas De Bruyckere; Jan Cosyn
Journal:  J Clin Med       Date:  2020-05-22       Impact factor: 4.241

7.  Effect of Flapless Immediate Implantation and Filling the Buccal Gap with Xenograft Material on the Buccal Bone Level: A Randomized Clinical Trial.

Authors:  Mojgan Paknejad; Solmaz Akbari; Hoori Aslroosta; Mehrdad Panjnoush; Samira Hajheidary
Journal:  J Dent (Tehran)       Date:  2017-11

8.  Tissue integration of zirconia and titanium implants with and without buccal dehiscence defects.

Authors:  Hyun-Chang Lim; Ronald Ernst Jung; Christoph Hans Franz Hämmerle; Myong Ji Kim; Kyeong-Won Paeng; Ui-Won Jung; Daniel Stefan Thoma
Journal:  J Periodontal Implant Sci       Date:  2018-06-30       Impact factor: 2.614

9.  Buccal bone thickness at dental implants in the maxillary anterior region with large bony defects at time of immediate implant placement: A 1-year cohort study.

Authors:  Henny J A Meijer; Kirsten W Slagter; Arjan Vissink; Gerry M Raghoebar
Journal:  Clin Implant Dent Relat Res       Date:  2018-12-11       Impact factor: 3.932

10.  Failure Modes and Survival of Anterior Crowns Supported by Narrow Implant Systems.

Authors:  Edmara T P Bergamo; Everardo N S de Araújo-Júnior; Adolfo C O Lopes; Paulo G Coelho; Abbas Zahoui; Ernesto B Benalcázar Jalkh; Estevam A Bonfante
Journal:  Biomed Res Int       Date:  2020-09-07       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.