Literature DB >> 22092443

Digital correction of motion artefacts in microscopy image sequences collected from living animals using rigid and nonrigid registration.

K S Lorenz1, P Salama, K W Dunn, E J Delp.   

Abstract

Digital image analysis is a fundamental component of quantitative microscopy. However, intravital microscopy presents many challenges for digital image analysis. In general, microscopy volumes are inherently anisotropic, suffer from decreasing contrast with tissue depth, lack object edge detail and characteristically have low signal levels. Intravital microscopy introduces the additional problem of motion artefacts, resulting from respiratory motion and heartbeat from specimens imaged in vivo. This paper describes an image registration technique for use with sequences of intravital microscopy images collected in time-series or in 3D volumes. Our registration method involves both rigid and nonrigid components. The rigid registration component corrects global image translations, whereas the nonrigid component manipulates a uniform grid of control points defined by B-splines. Each control point is optimized by minimizing a cost function consisting of two parts: a term to define image similarity, and a term to ensure deformation grid smoothness. Experimental results indicate that this approach is promising based on the analysis of several image volumes collected from the kidney, lung and salivary gland of living rodents.
© 2011 The Authors Journal of Microscopy © 2011 Royal Microscopical Society.

Entities:  

Mesh:

Year:  2011        PMID: 22092443      PMCID: PMC3856233          DOI: 10.1111/j.1365-2818.2011.03557.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  26 in total

1.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

Review 2.  Intravital imaging of cell movement in tumours.

Authors:  John Condeelis; Jeffrey E Segall
Journal:  Nat Rev Cancer       Date:  2003-12       Impact factor: 60.716

3.  Volume-preserving nonrigid registration of MR breast images using free-form deformation with an incompressibility constraint.

Authors:  Torsten Rohlfing; Calvin R Maurer; David A Bluemke; Michael A Jacobs
Journal:  IEEE Trans Med Imaging       Date:  2003-06       Impact factor: 10.048

4.  Semi-automatic deformable registration of prostate MR images to pathological slices.

Authors:  Yousef Mazaheri; Louisa Bokacheva; Dirk-Jan Kroon; Oguz Akin; Hedvig Hricak; Daniel Chamudot; Samson Fine; Jason A Koutcher
Journal:  J Magn Reson Imaging       Date:  2010-11       Impact factor: 4.813

5.  In vivo imaging of amyloid-beta deposits in mouse brain with multiphoton microscopy.

Authors:  Jesse Skoch; Gregory A Hickey; Stephen T Kajdasz; Bradley T Hyman; Brian J Bacskai
Journal:  Methods Mol Biol       Date:  2005

Review 6.  Principles of two-photon excitation microscopy and its applications to neuroscience.

Authors:  Karel Svoboda; Ryohei Yasuda
Journal:  Neuron       Date:  2006-06-15       Impact factor: 17.173

7.  The normal kidney filters nephrotic levels of albumin retrieved by proximal tubule cells: retrieval is disrupted in nephrotic states.

Authors:  L M Russo; R M Sandoval; M McKee; T M Osicka; A B Collins; D Brown; B A Molitoris; W D Comper
Journal:  Kidney Int       Date:  2007-01-17       Impact factor: 10.612

8.  A pyramid approach to subpixel registration based on intensity.

Authors:  P Thévenaz; U E Ruttimann; M Unser
Journal:  IEEE Trans Image Process       Date:  1998       Impact factor: 10.856

9.  Two-photon laser scanning fluorescence microscopy.

Authors:  W Denk; J H Strickler; W W Webb
Journal:  Science       Date:  1990-04-06       Impact factor: 47.728

10.  Mitochondrial permeability transition in liver ischemia and reperfusion: role of c-Jun N-terminal kinase 2.

Authors:  Tom P Theruvath; Mark C Snoddy; Zhi Zhong; John J Lemasters
Journal:  Transplantation       Date:  2008-05-27       Impact factor: 4.939

View more
  11 in total

1.  Automatic detection of motion blur in intravital video microscopy image sequences via directional statistics of log-Gabor energy maps.

Authors:  Ricardo J Ferrari; Carlos H Villa Pinto; Bruno C Gregório da Silva; Danielle Bernardes; Juliana Carvalho-Tavares
Journal:  Med Biol Eng Comput       Date:  2014-11-04       Impact factor: 2.602

2.  Segmentation of biological images containing multitarget labeling using the jelly filling framework.

Authors:  Neeraj J Gadgil; Paul Salama; Kenneth W Dunn; Edward J Delp
Journal:  J Med Imaging (Bellingham)       Date:  2018-11-23

3.  A simple approach for measuring FRET in fluorescent biosensors using two-photon microscopy.

Authors:  Richard N Day; Wen Tao; Kenneth W Dunn
Journal:  Nat Protoc       Date:  2016-09-29       Impact factor: 13.491

4.  A motion correction framework for time series sequences in microscopy images.

Authors:  Ankur N Kumar; Kurt W Short; David W Piston
Journal:  Microsc Microanal       Date:  2013-02-15       Impact factor: 4.127

5.  Long-term time-lapse multimodal intravital imaging of regeneration and bone-marrow-derived cell dynamics in skin.

Authors:  Benedikt W Graf; Eric J Chaney; Marina Marjanovic; Steven G Adie; Michael De Lisio; M Carmen Valero; Marni D Boppart; Stephen A Boppart
Journal:  Technology       Date:  2013-09-24

Review 6.  The Indiana O'Brien Center for Advanced Renal Microscopic Analysis.

Authors:  Kenneth W Dunn; Bruce A Molitoris; Pierre C Dagher
Journal:  Am J Physiol Renal Physiol       Date:  2021-03-08

Review 7.  Intravital microscopy: a practical guide on imaging intracellular structures in live animals.

Authors:  Andrius Masedunskas; Oleg Milberg; Natalie Porat-Shliom; Monika Sramkova; Tim Wigand; Panomwat Amornphimoltham; Roberto Weigert
Journal:  Bioarchitecture       Date:  2012-09-01

8.  Quantitative Kinetic Models from Intravital Microscopy: A Case Study Using Hepatic Transport.

Authors:  Meysam Tavakoli; Konstantinos Tsekouras; Richard Day; Kenneth W Dunn; Steve Pressé
Journal:  J Phys Chem B       Date:  2019-08-15       Impact factor: 3.466

9.  IMART software for correction of motion artifacts in images collected in intravital microscopy.

Authors:  Kenneth W Dunn; Kevin S Lorenz; Paul Salama; Edward J Delp
Journal:  Intravital       Date:  2014

Review 10.  Multiphoton intravital microscopy in small animals: motion artefact challenges and technical solutions.

Authors:  D Soulet; J Lamontagne-Proulx; B Aubé; D Davalos
Journal:  J Microsc       Date:  2020-03-05       Impact factor: 1.758

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.