Hip strength assessment using handheld dynamometry is subject to intertester bias when testers are of different sex and strength.

K Thorborg1, T Bandholm, M Schick, J Jensen, P Hölmich.   

Abstract

Handheld dynamometry (HHD) is a promising tool for obtaining reliable hip strength measurements in the clinical setting, but intertester reliability has been questioned, especially in situations where testers exhibit differences in upper-extremity muscle strength (male vs female). The purpose of this study was to examine the intertester reliability concerning strength assessments of hip abduction, adduction, external and internal rotation, flexion and extension using HHD, and to test whether systematic differences in test values exist between testers of different upper-extremity strength. Fifty healthy individuals (29 women), aged 25 ± 5 years were included. Two physiotherapist students (one female, one male) of different upper-extremity strength performed the measurements. The tester order and strength test order were randomized. Intraclass correlation coefficients were used to quantify reliability, and ranged from 0.82 to 0.91 for the six strength test. The female tester systematically measured lower strength values for all isometric strength tests (P < 0.05). In hip strength assessments using HHD, systematic bias exists between testers of different sex, which is likely explained by differences in upper-extremity strength. Hence, to improve intertester reliability, the dynamometer likely needs external fixation, as this will eliminate the influence of differences in upper-extremity strength between testers.
© 2011 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  athletes; groin; handheld dynamometer; hip strength; reproducibility

Mesh:

Year:  2011        PMID: 22092308     DOI: 10.1111/j.1600-0838.2011.01405.x

Source DB:  PubMed          Journal:  Scand J Med Sci Sports        ISSN: 0905-7188            Impact factor:   4.221


  22 in total

1.  Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable.

Authors:  Kristian Thorborg; Thomas Bandholm; Per Hölmich
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-07       Impact factor: 4.342

2.  Eccentric and isometric shoulder rotator cuff strength testing using a hand-held dynamometer: reference values for overhead athletes.

Authors:  Ann M J Cools; Fran Vanderstukken; Frédéric Vereecken; Mattias Duprez; Karel Heyman; Nick Goethals; Fredrik Johansson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-08-21       Impact factor: 4.342

3.  RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER.

Authors:  Martin Alfuth; Magali Murielle Hahm
Journal:  Int J Sports Phys Ther       Date:  2016-02

4.  Measuring Eccentric Strength of the Shoulder External Rotators Using a Handheld Dynamometer: Reliability and Validity.

Authors:  Fredrik R Johansson; Eva Skillgate; Mattis L Lapauw; Dorien Clijmans; Valentijn P Deneulin; Tanneke Palmans; Human Kinetic Engineer; Ann M Cools
Journal:  J Athl Train       Date:  2015-05-14       Impact factor: 2.860

5.  Normative values of eccentric hip abduction strength in novice runners: an equation adjusting for age and gender.

Authors:  D Ramskov; M B Pedersen; K Kastrup; S Lønbro; J S Jacobsen; K Thorborg; R O Nielsen; S Rasmussen
Journal:  Int J Sports Phys Ther       Date:  2014-02

6.  A NEW CLINICAL MUSCLE FUNCTION TEST FOR ASSESSMENT OF HIP EXTERNAL ROTATION STRENGTH: AUGUSTSSON STRENGTH TEST.

Authors:  Jesper Augustsson
Journal:  Int J Sports Phys Ther       Date:  2016-08

7.  THE INFLUENCE OF HIP JOINT ANGLE ON THE RATIO BETWEEN ADDUCTION AND ABDUCTION TORQUE IN EXPERIENCED, RECREATIONAL MALE ICE HOCKEY PLAYERS.

Authors:  Patrick Welsh; Scott Howitt; Samuel J Howarth
Journal:  Int J Sports Phys Ther       Date:  2020-02

8.  MEASURES OF HIP MUSCLE STRENGTH AND RATE OF FORCE DEVELOPMENT USING A FIXATED HANDHELD DYNAMOMETER: INTRA-TESTER INTRA-DAY RELIABILITY OF A CLINICAL SET-UP.

Authors:  Lasse Ishøi; Per Hölmich; Kristian Thorborg
Journal:  Int J Sports Phys Ther       Date:  2019-09

9.  Standardizing Muscle Strength Measurement in Femoroacetabular Impingement Syndrome: Letter to the Editor.

Authors:  Arman Memarzadeh; Andrew Paul Morrison; Leica Sarah Claydon-Mueller; Vikas Khanduja
Journal:  Sports Health       Date:  2020-11-24       Impact factor: 3.843

10.  Reliability of hip muscle strength measured in principal and intermediate planes of movement.

Authors:  Basilio A M Goncalves; David J Saxby; Adam Kositsky; Rod S Barrett; Laura E Diamond
Journal:  PeerJ       Date:  2021-06-02       Impact factor: 2.984

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.