Literature DB >> 22092198

Comparison of the mechanical behaviors of locked and nonlocked plate/screw fixation applied to experimentally induced rotational osteotomies in canine ilia.

Joseph Brad Case1, Casey Dean, David M Wilson, John M Knudsen, Susan P James, Ross H Palmer.   

Abstract

OBJECTIVE: To compare the mechanical behaviors of 2 locked (parallel and diverging screws) and 1 nonlocked (NL) version of triple pelvic osteotomy (TPO) plate/screw fixation. STUDY
DESIGN: In vitro biomechanical evaluation. ANIMALS: Cadaveric canine hemipelves.
METHODS: Comparison 1-NL screws 20° TPO (NL-20) construct versus locked parallel (LP) screws 20° TPO (LP-20) construct (n = 7). Comparison 2-LP-20 construct versus locked diverging (LD) screws 20° TPO (LD-20) construct (n = 6). Condition 1-Nondestructive loading to determine stiffness. Condition 2-Cyclic loading to determine stiffness, screw loosening, and osteotomy gap displacement. Condition 3-Load to failure (yield load, yield displacement, maximum load, load to failure, failure mode).
RESULTS: Stiffness was not significantly different for NL-20 versus LP-20 constructs (P = .48) or for LP-20 versus LD-20 constructs (P = .83). Screw loosening was significantly more frequent for NL-20 versus LP-20 (P = .01) and for LD-20 versus LP-20 constructs (P = .02). The relative risk for screw loosening with NL-20 constructs versus LP-20 constructs was 1.4 (95% CI: 1.1-1.8). The relative risk for screw loosening with LD-20 versus LP-20 was 1.6 (95% CI: 1.1-2.2). Yield load was significantly greater for LP-20 versus NL-20 and LD-20 constructs (P = .04, P = .03), respectively.
CONCLUSIONS: No TPO constructs tested maintained complete integrity after cyclic loading; however, screw loosening was significantly reduced and yield loads were significantly larger for LP-20 plate/screw constructs. © Copyright 2011 by The American College of Veterinary Surgeons.

Entities:  

Mesh:

Year:  2011        PMID: 22092198     DOI: 10.1111/j.1532-950X.2011.00913.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  4 in total

1.  A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model.

Authors:  Allison R Kenzig; James R Butler; Lauren B Priddy; Kristen R Lacy; Steven H Elder
Journal:  BMC Vet Res       Date:  2017-07-13       Impact factor: 2.741

2.  Preliminary study on a novel dedicated plate for iliac fractures in dogs.

Authors:  Tryssia S M Moi; Bruno W Minto; Ana P Macedo; Dayvid V F Lucena; Caio A S Malta; Luis G G G Dias
Journal:  PLoS One       Date:  2022-08-26       Impact factor: 3.752

3.  Stress and stability comparison between different systems for high tibial osteotomies.

Authors:  Chu-An Luo; Shi-Yuan Hua; Shang-Chih Lin; Chun-Ming Chen; Ching-Shiow Tseng
Journal:  BMC Musculoskelet Disord       Date:  2013-03-25       Impact factor: 2.362

4.  Pelvic modelling and the comparison between plate position for double pelvic osteotomy using artificial cancellous bone and finite element analysis.

Authors:  William McCartney; Bryan MacDonald; Ciprian Andrei Ober; Rubén Lostado-Lorza; Fátima Somovilla Gómez
Journal:  BMC Vet Res       Date:  2018-03-20       Impact factor: 2.741

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.