Effects of stimulation parameters and electrode location on thresholds for epidural stimulation of cat motor cortex.

Amorn Wongsarnpigoon1, Warren M Grill.   

Abstract

Epidural electrical stimulation (ECS) of the motor cortex is a developing therapy for neurological disorders. Both placement and programming of ECS systems may affect the therapeutic outcome, but the treatment parameters that will maximize therapeutic outcomes and minimize side effects are not known. We delivered ECS to the motor cortex of anesthetized cats and investigated the effects of electrode placement and stimulation parameters on thresholds for evoking motor responses in the contralateral forelimb. Thresholds were inversely related to stimulation frequency and the number of pulses per stimulus train. Thresholds were lower over the forelimb representation in motor cortex (primary site) than surrounding sites (secondary sites), and thresholds at sites <4 mm away from the primary site were significantly lower than at sites >4 mm away. Electrode location and montage influenced the effects of polarity on thresholds: monopolar anodic and cathodic thresholds were not significantly different over the primary site, cathodic thresholds were significantly lower than anodic thresholds over secondary sites and bipolar thresholds were significantly lower with the anode over the primary site than with the cathode over the primary site. A majority of bipolar thresholds were either between or equal to the respective monopolar thresholds, but several bipolar thresholds were greater than or less than the monopolar thresholds of both the anode and cathode. During bipolar stimulation, thresholds were influenced by both electric field superposition and indirect, synaptically mediated interactions. These results demonstrate the influence of stimulation parameters and electrode location during cortical stimulation, and these effects should be considered during the programming of systems for therapeutic cortical stimulation.

Entities:  

Mesh:

Year:  2011        PMID: 22086218     DOI: 10.1088/1741-2560/8/6/066016

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  1 in total

1.  Evaluation of optimal electrode configurations for epidural spinal cord stimulation in cervical spinal cord injured rats.

Authors:  Monzurul Alam; Guillermo Garcia-Alias; Prithvi K Shah; Yury Gerasimenko; Hui Zhong; Roland R Roy; V Reggie Edgerton
Journal:  J Neurosci Methods       Date:  2015-03-16       Impact factor: 2.390

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.