Literature DB >> 22074665

Three-dimensional paper-based electrochemiluminescence immunodevice for multiplexed measurement of biomarkers and point-of-care testing.

Lei Ge1, Jixian Yan, Xianrang Song, Mei Yan, Shenguang Ge, Jinghua Yu.   

Abstract

In this work, electrochemiluminescence (ECL) immunoassay was introduced into the recently proposed microfluidic paper-based analytical device (μPADs) based on directly screen-printed electrodes on paper for the very first time. The screen-printed paper-electrodes will be more important for further development of this paper-based ECL device in simple, low-cost and disposable application than commercialized ones. To further perform high-performance, high-throughput, simple and inexpensive ECL immunoassay on μPAD for point-of-care testing, a wax-patterned three-dimensional (3D) paper-based ECL device was demonstrated for the very first time. In this 3D paper-based ECL device, eight carbon working electrodes including their conductive pads were screen-printed on a piece of square paper and shared the same Ag/AgCl reference and carbon counter electrodes on another piece of square paper after stacking. Using typical tris-(bipyridine)-ruthenium (Ⅱ) - tri-n-propylamine ECL system, the application test of this 3D paper-based ECL device was performed through the diagnosis of four tumor markers in real clinical serum samples. With the aid of a facile device-holder and a section-switch assembled on the analyzer, eight working electrodes were sequentially placed into the circuit to trigger the ECL reaction in the sweeping range from 0.5 to 1.1 V at room temperature. In addition, this 3D paper-based ECL device can be easily integrated and combined with the recently emerging paper electronics to further develop simple, sensitive, low-cost, disposable and portable μPAD for point-of-care testing, public health and environmental monitoring in remote regions, developing or developed countries.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22074665     DOI: 10.1016/j.biomaterials.2011.10.065

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  44 in total

1.  A microfluidic paper-based analytical device for rapid quantification of particulate chromium.

Authors:  Poomrat Rattanarat; Wijitar Dungchai; David M Cate; Weena Siangproh; John Volckens; Orawon Chailapakul; Charles S Henry
Journal:  Anal Chim Acta       Date:  2013-09-12       Impact factor: 6.558

Review 2.  Biomarker detection for disease diagnosis using cost-effective microfluidic platforms.

Authors:  Sharma T Sanjay; Guanglei Fu; Maowei Dou; Feng Xu; Rutao Liu; Hao Qi; XiuJun Li
Journal:  Analyst       Date:  2015-11-07       Impact factor: 4.616

3.  A colorimetric paper-based ATONP-ALP nanobiosensor for selective detection of Cd2+ ions in clams and mussels.

Authors:  Krishna Kumari Swain; Sunil Bhand
Journal:  Anal Bioanal Chem       Date:  2021-02-10       Impact factor: 4.142

Review 4.  A review on wax printed microfluidic paper-based devices for international health.

Authors:  S Altundemir; A K Uguz; K Ulgen
Journal:  Biomicrofluidics       Date:  2017-08-30       Impact factor: 2.800

Review 5.  Paper-based assays for urine analysis.

Authors:  Eric Lepowsky; Fariba Ghaderinezhad; Stephanie Knowlton; Savas Tasoglu
Journal:  Biomicrofluidics       Date:  2017-10-17       Impact factor: 2.800

6.  Paper-based chemiluminescence immunodevice for the carcinoembryonic antigen by employing multi-enzyme carbon nanosphere signal enhancement.

Authors:  Ying Chen; Weiru Chu; Wei Liu; Xiaoyan Guo; Yan Jin; Baoxin Li
Journal:  Mikrochim Acta       Date:  2018-02-19       Impact factor: 5.833

Review 7.  Paper-based analytical devices for clinical diagnosis: recent advances in the fabrication techniques and sensing mechanisms.

Authors:  Mazhar Sher; Rachel Zhuang; Utkan Demirci; Waseem Asghar
Journal:  Expert Rev Mol Diagn       Date:  2017-04       Impact factor: 5.225

8.  Paper-based electrochemiluminescent screening for genotoxic activity in the environment.

Authors:  Vigneshwaran Mani; Karteek Kadimisetty; Spundana Malla; Amit A Joshi; James F Rusling
Journal:  Environ Sci Technol       Date:  2013-02-01       Impact factor: 9.028

9.  Synthesis, labeling and bioanalytical applications of a tris(2,2'-bipyridyl)ruthenium(II)-based electrochemiluminescence probe.

Authors:  Xiaoming Zhou; Debin Zhu; Yuhui Liao; Weipeng Liu; Hongxing Liu; Zhaokui Ma; Da Xing
Journal:  Nat Protoc       Date:  2014-04-17       Impact factor: 13.491

10.  Low-voltage paper isotachophoresis device for DNA focusing.

Authors:  Xiang Li; Long Luo; Richard M Crooks
Journal:  Lab Chip       Date:  2015-09-04       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.