Literature DB >> 22072870

Intratracheal instillation of cerium oxide nanoparticles induces hepatic toxicity in male Sprague-Dawley rats.

Siva K Nalabotu1, Madhukar B Kolli, William E Triest, Jane Y Ma, Nandini D P K Manne, Anjaiah Katta, Hari S Addagarla, Kevin M Rice, Eric R Blough.   

Abstract

BACKGROUND: Cerium oxide (CeO(2)) nanoparticles have been posited to have both beneficial and toxic effects on biological systems. Herein, we examine if a single intratracheal instillation of CeO(2) nanoparticles is associated with systemic toxicity in male Sprague-Dawley rats. METHODS AND
RESULTS: Compared with control animals, CeO(2) nanoparticle exposure was associated with increased liver ceria levels, elevations in serum alanine transaminase levels, reduced albumin levels, a diminished sodium-potassium ratio, and decreased serum triglyceride levels (P < 0.05). Consistent with these data, rats exposed to CeO(2) nanoparticles also exhibited reductions in liver weight (P < 0.05) and dose-dependent hydropic degeneration, hepatocyte enlargement, sinusoidal dilatation, and accumulation of granular material. No histopathological alterations were observed in the kidney, spleen, and heart. Analysis of serum biomarkers suggested an elevation of acute phase reactants and markers of hepatocyte injury in the rats exposed to CeO(2) nanoparticles.
CONCLUSION: Taken together, these data suggest that intratracheal instillation of CeO(2) nanoparticles can result in liver damage.

Entities:  

Keywords:  cerium oxide nanoparticles; hepatic toxicity; hydropic degeneration; systemic toxicity

Mesh:

Substances:

Year:  2011        PMID: 22072870      PMCID: PMC3205129          DOI: 10.2147/IJN.S25119

Source DB:  PubMed          Journal:  Int J Nanomedicine        ISSN: 1176-9114


Introduction

Cerium is a rare earth lanthanide metal and a strong oxidizing agent. Cerium exists both in the trivalent state (Ce3+, cerous) and very stable tetravalent state (Ce4+, ceric) as cerium oxide (CeO2).1 CeO2 is widely used as a polishing agent for glass mirrors, television tubes, and ophthalmic lenses.2 In addition, CeO2 can also act as a catalyst because it can both accept and donate oxygen.3 This latter property has led to the widespread use of CeO2 in the automobile industry, where it has been used to increase fuel efficiency and reduce particulate emissions.4–6 It appears that CeO2 nanoparticles may also be capable of acting as antioxidants, which has led some to postulate that these particles may be useful for the treatment of cardiovascular disease,7 neurodegenerative disease,8 and radiation-induced tissue damage.9,10 Nonetheless, other in vitro work has shown that CeO2 nanoparticles can also cause oxidative stress.11 The Organization for Economic Co-operation and Development Working Party on Manufactured Nanomaterials has demarcated CeO2 nanoparticles along with 14 other nanoparticles as a high-priority for evaluation.12 Given current industrial applications, it is thought that the most common route of CeO2 exposure is likely to be through inhalation and/or ingestion. Although previous studies have shown that intratracheal instillation of CeO2 nanoparticles can cause a toxicological response in the lung, whether these particles also exhibit systemic toxicity is currently unclear.2,13 Therefore, the purpose of the current study was to determine if the intratracheal instillation of CeO2 nanoparticles is associated with alterations in the indices of systemic toxicity and pathological change. On the basis of previous work examining the translocation of carbon nanotubes from the lung,14 we hypothesized that intratracheal instillation of CeO2 nanoparticles could lead to nanoparticle deposition in other organs through the circulation. Consistent with this hypothesis, our data suggest that the intratracheal instillation of CeO2 nanoparticles is associated with increased liver ceria levels, reductions in liver weight, and evidence of liver damage.

Materials and methods

Particle characterization

CeO2 nanoparticles, 10 wt% in water (average diameter approximately 20 nm), were obtained from Sigma-Aldrich (St Louis, MO) as previously outlined.13 Normal saline was used as vehicle to suspend the nanoparticles prior to instillation. CeO2 samples diluted in saline were used for animal exposures. Since the CeO2 nanoparticles form agglomerates in suspension, the size distribution of the agglomerates of CeO2 was analyzed using field emission scanning electron microscopy and transmission electron microscopy (TEM). The CeO2 suspension was analyzed using field emission scanning electron microscopy as follows: the CeO2 particle suspensions were diluted with distilled water (about 10-fold) and were dried on carbon planchet and sputter-coated. After sputter-coating, the specimens were examined with a Hitachi Model S-4800 field emission scanning electron microscope (Schaumburg, IL) between 5 kV and 20 kV. In addition, the particles were diluted in double distilled filtered water and a drop was placed on a formvar-coated copper grid to dry before viewing the samples with a JEOL 1220 TEM (Tokyo, Japan).

Animal handling and instillation of CeO2 nanoparticles

Specific pathogen-free male Sprague-Dawley (Hla: SD-CVF) rats (6 weeks old) were purchased from Hilltop Laboratories (Scottdale, PA). Rats were kept in cages individually and ventilated with HEPA filtered air in an animal facility accredited by the Association for Assessment and Accreditation of Laboratory Animal Care International. After acclimatization for one week, the rats were randomly divided into four groups (n = 7 per group) to receive vehicle control (saline, 0.9% NaCl), or instillation of 1.0, 3.5, or 7.0 mg/kg CeO2 nanoparticles. Rats were anesthetized with sodium methohexital (35 mg/kg, intraperitoneally) and placed on an inclined restraint board before instillation with 0.3 mL of saline suspension or CeO2 nanoparticles. The animals were euthanized 28 days post-exposure by drug overdose according to the Guide for the Care and Use of Laboratory Animals and as approved by the National Institute for Occupational Safety and Health Animal Care and Use Committee. All animals were humanely treated and were monitored for any potential suffering.

Determination of cerium content in the liver

Liver cerium content was estimated by induction coupled plasma-mass spectrometry (ICP-MS) at Elemental Analysis Inc (Lexington, KY) according to the standard protocol.14 Briefly, liver samples (n = 4 for each group) were prepared using Environmental Protection Agency method 3050B for the analysis of total cerium by ICP-MS. A 2.5 g sample was weighed to the nearest 0.0001 g and digested with concentrated nitric acid, 30% hydrogen peroxide, and concentrated hydrochloric acid. A method blank, laboratory control sample, a laboratory duplicate, and a predigestion matrix spike were prepared for each sample. After digestion, the extracts and the quality control samples were diluted to a final volume of 50 mL before analysis using an Agilent 7500cx ICP-MS. The instrument was calibrated for Ce-140 with 0, 0.1, 1.0, 10.0, and 100 μg/L standards prepared from a certified reference standard traceable to National Institute of Standards and Technology reference materials. A second source calibration verification standard traceable to National Institute of Standards and Technology reference materials was analyzed to verify the calibration standards. A continuing calibration verification standard and a continuing calibration blank were analyzed at the beginning of the run, after every ten samples, and at the conclusion of the run.

Serum biochemical and lipid profile analysis

Blood was collected by cardiac puncture into a serum collection tube (BD Vacutainer®) before centrifugation at 800× g for 15 minutes. Serum was collected and used for biochemical assays using an Abaxis VetScan® analyzer (Abaxis, Union City, CA). Serum biochemical parameters, ie, alanine aminotransferase, alkaline phosphatase, bilirubin, blood urea nitrogen, albumin, calcium (Ca2+), creatinine, amylase, globulin, potassium (K+), sodium (Na+), phosphorus, total bilirubin, and total protein were evaluated with a Comprehensive Diagnostic Profile Disk. The lipid profile, ie, total cholesterol, triglycerides, and high-density lipoprotein was measured using lipid profile-Glu cassettes (Cholestech LDX) and a Cholestech LDX® analyzer. The remaining serum was stored at −80°C.

Multiplexed serum protein immunoassays

Pooled serum samples from all seven animals in each experimental group were shipped on dry ice to Rules-Based Medicine (Austin, TX) for Rodent MAP® version 2.0 antigen analysis using a Luminex 100 instrument, as detailed elsewhere.14 The antigen panel consisted of 59 proteins, which included proteins involved in inflammation, cytokines, growth factors, and tissue factors. Each analyte was quantified using 4 and 5 parameter, weighted and nonweighted curve fitting algorithms using proprietary data analysis software developed at Rules-Based Medicine.

Tissue collection and histopathological examination

Liver, kidney, spleen, and heart were collected at the time of death. Each tissue was weighed and then fixed in FineFIX™ (Milestone medicals, Shelton, CT) preservative for later histopathological examination. Tissues from liver, spleen, kidney, and heart were embedded in paraffin wax, sectioned at 5 μm, mounted on glass slide and stained with hematoxylin-eosin using standard histopathological techniques. Sections were examined by light microscopy in a blinded fashion by a board certified pathologist.

Data analysis

Results are presented as the mean ± standard error of the mean. Data were analyzed using the SigmaPlot 11.0 statistical program. One-way analysis of variance was performed for overall comparisons, while the Student–Newman–Keuls post hoc test was used to determine differences between groups. Values of P < 0.05 were considered to be statistically significant.

Results

Nanoparticle characterization

Similar to previous work using the same batch of CeO2 nanoparticles,13 analysis of nanoparticle size by TEM and scanning electron microscopy confirmed the presence of single and agglomerated CeO2 nanoparticles in the suspensions (Figure 1A and B). Field emission scanning electron microscopy showed that the CeO2 nano particles were generally dispersed into submicron groups with an average size of 9.26 ± 0.58 nm. The diameter of the primary CeO2 particles was determined to be 10.14 ± 0.76 nm by TEM.
Figure 1

Characterization of the cerium oxide nanoparticles by (A) field emission scanning electron microscopy and (B) transmission electron microscopy (scale bar = 200 nm) of a dilute cerium oxide suspension.

CeO2 instillation decreases liver wet weight

CeO2 instillation at the 1, 3.5, or 7 mg/kg dosages had no significant effect on rat body, heart, kidney, or spleen weight (Table 1). Compared with control animals, only the highest CeO2 dosage (7 mg/kg) decreased liver weight (saline control 14.55 ± 0.27 versus CeO2 7.0 mg/kg 12.50 ± 0.54; P < 0.05, Table 1).
Table 1

Alterations in absolute organ wet weight 28 days after intratracheal instillation of cerium oxide nanoparticles

Organ weight (g)Saline control (n = 7)CeO2 1.0 mg/kg (n = 7)CeO2 3.5 mg/kg (n = 7)CeO2 7.0 mg/kg (n = 7)
Heart (g)1.52 ± 0.151.35 ± 0.051.27 ± 0.071.23 ± 0.05
Liver (g)14.55 ± 0.2714.30 ± 1.0414.78 ± 0.5712.50 ± 0.54*
Kidney (g)2.67 ± 0.312.55 ± 0.212.54 ± 0.332.43 ± 0.31
Spleen (g)0.58 ± 0.060.65 ± 0.100.56 ± 0.080.64 ± 0.04

Note: Significantly different from vehicle control (P < 0.05).

CeO2 instillation increases liver ceria content

The ceria content of animals instilled with 7.0 mg/kg CeO2 nanoparticles was higher than that observed in the other groups (saline control nondetectable versus 1.0 mg/kg CeO2: 0.05 ± 0.01 ppm versus 3.5 mg/kg CeO2: 0.11 ± 0.02 ppm versus CeO2 7.0 mg/kg: 0.50 ± 0.18 ppm; P < 0.05; Figure 2).
Figure 2

Concentration of cerium in liver after intratracheal instillation of cerium oxide nanoparticles.

Note: *Significantly different from the vehicle control (P < 0.05).

Effect of CeO2 instillation on serum biochemical profile

Table 2 shows the alterations of the serum biochemical parameters following CeO2 nanoparticle exposure. Compared with control animals, CeO2 instillation at 1, 3.5, or 7 mg/kg diminished the sodium to potassium ratio (P < 0.05), while the CeO2 dosage of 7 mg/kg increased serum alanine aminotransferase levels and reduced albumin levels (P < 0.05). The serum lipid profile analysis (Table 2B) indicated a reduction in the triglyceride levels with 7 mg/kg CeO2 nanoparticle exposure.
Table 2

Changes in serum biochemical parameters (A) and lipid profile (B) 28 days after the intratracheal instillation of cerium oxide nanoparticles

AnalyteSaline control (n = 7)CeO2 1.0 mg/kg (n = 7)CeO2 3.5 mg/kg (n = 7)CeO2 7.0 mg/kg (n = 7)
A
Glucose186.4 ± 25.7208 ± 43.0197.6 ± 40.2231 ± 93.5
ALP276.1 ± 53.7263 ± 55.4242 ± 35.3222.23 ± 81.9
ALT58.3 ± 10.783.4 ± 28.588.3 ± 31.4130.5 ± 94.5*
Amylase974.7 ± 97.41055.1 ± 124.2991.4 ± 116908.4 ± 277.0
Total protein6.0 ± 0.15.9 ± 0.66.2 ± 0.55.4 ± 1.3
Albumin4.2 ± 0.24.1 ± 0.54.5 ± 0.43.5 ± 1.1*
Globulin1.8 ± 0.21.8 ± 0.22.0 ± 0.21.8 ± 0.2
ALB-GLOB ratio2.3 ± 0.32.3 ± 0.32.2 ± 0.31.9 ± 0.6
BUN15.4 ± 1.115 ± 3.115.7 ± 1.914.4 ± 4.2
Creatinine0.3 ± 0.10.27 ± 0.10.23 ± 0.10.28 ± 0.1
Ca2+11.4 ± 0.710.7 ± 1.311.5 ± 1.110.4 ± 2.4
Phosphorus8.6 ± 0.97.9 ± 1.28.7 ± 1.08.2 ± 1.9
Na+142.3 ± 0.9138 ± 10.7138.1 ± 10.7132.1 ± 16.3
K+5.5 ± 0.46.0 ± 0.56.5 ± 0.65.8 ± 0.9
Na+-K+ ratio25.8 ± 2.022.9 ± 1.7*21.2 ± 1.4*22.8 ± 2.5*
B
Total cholesterol100.7 ± 1.9100 ± 0100 ± 0103.1 ± 8.3
Triglycerides143 ± 53109.6 ± 50.9190.3 ± 83.793.1 ± 22.3*
HDL21 ± 6.019.4 ± 5.420 ± 6.419 ± 5.1

Note: Significantly different from the vehicle control (P < 0.05).

Abbreviations: ALP, alkaline phosphatase; ALT, alanine aminotransferase; ALB-GLOB ratio, albumin to globulin ratio; BUN, blood urea nitrogen; Ca, calcium; Na, sodium; K, potassium; Na-K ratio, sodium to potassium ratio; HDL, high density lipoproteins.

CeO2 nanoparticle exposure is associated with evidence of liver pathology

The primary alterations considered for liver tissue damage were hydropic degeneration of the hepatocytes, dilation of the sinusoids, portal inflammation, and fibrosis of the liver compared to tissues obtained from control animals. CeO2 nanoparticle exposure showed widespread hydropic degeneration of hepatocytes around the central vein region with sparing of the immediate periportal region (Figure 3). These changes were panlobular in nature. Along with hydropic degeneration, we also observed enlargement of the hepatocytes, enlargement of the nucleus in the hepatocyte, binucleation of some hepatocytes, dilatation of the sinusoids, and occasional focal inflammation areas in a few of the exposed animals (Figure 4). As the dose of the nanoparticles was increased, the number of hepatocytes that show hydropic degeneration was also elevated suggesting that changes in hepatocyte structure were dose-dependent.
Figure 3

Cerium oxide nanoparticle exposure alters histopathological architecture of the liver. (A) Saline control (400×), (B) CeO2 at 1.0 mg/kg (400×), (C) CeO2 3.5 mg/kg (400×), and (D) CeO2 7.0 mg/kg (400×). Note evidence of hydropic degeneration (arrow) with CeO2 instillation.

Figure 4

Histopathological alterations with the CeO2 nanoparticle exposure (7.0 mg/kg) include (A) focal inflammation, (B) sinusoidal dilatation, and (C) binucleation of the hepatocyte (400×).

CeO2 nanoparticle exposure does not appear to affect spleen, kidney, and heart

Alterations considered for the kidney pathologies were necrosis of the proximal tubular epithelium, tubular accumulation of proteinaceous material, and inflammatory reaction in the interstitial areas of the cortex and medulla. Spleen and heart tissues were examined for any histological alterations in structure along with the infiltration of inflammatory cells. We did not observe any alterations in the histological appearance or the infiltration of inflammatory cells in the kidney, spleen, and heart with CeO2 nanoparticle exposure (Figures 5–7).
Figure 5

Cerium oxide nanoparticle exposure has no effect on the histological appearance of the kidney. (A) Saline control (400×), (B) CeO2 at 1.0 mg/kg (400×), (C) CeO2 3.5 mg/kg (400×), and (D) CeO2 7.0 mg/kg (400×).

Figure 7

Cerium oxide nanoparticle exposure has no effect on histological appearance of heart. (A) saline control (400×), (B) CeO2 at 1.0 mg/kg (400×), (C) CeO2 3.5 mg/kg (400×), and (D) CeO2 7.0 mg/kg (400×).

Effect of CeO2 instillation on serum protein expression

A panel of 59 protein biomarkers comprising cytokines, inflammatory markers, growth factors, and tissue factors were quantified in the serum samples collected in this study using the RBM RodentMAP® V2.0 multiplex immune assay service. Compared with levels observed in the control animals, the levels of 16 different analytes appeared to exhibit a trend towards being increased or decreased by at least 15% or more following the instillation procedure with the CeO2 nanoparticles (Figure 8A, B, and C). At the 7.0 mg/kg CeO2 dosage, ten of the analytes (fibroblast growth factor-basic, haptoglobin, immunoglobulin A, interleukin-11, matrix metalloproteinase- 9, myoglobin, serum amyloid protein, serum glutamic oxaloacetic, transaminase thrombopoietin, and von Willebrand factor) exhibited a trend towards increased expression whereas two (tumor necrosis factor-related activation protein (CD-40 L) and interleukin-7) appeared to exhibit a trend towards decreased expression (Figure 8C).
Figure 8

Cerium oxide nanoparticles exposure results in alterations in the expression of serum protein biomarkers.

Discussion

Investigation of the effects that nanomaterials may have on cellular function is essential for ensuring that the utilization of these materials in industrial or medical applications is safe. Although CeO2 nanoparticles have demonstrated excellent potential for biomedical use,7,8,10 limited knowledge exists concerning their potential systemic toxicity. The primary finding of this investigation was that intratracheal instillation of CeO2 nanoparticles (Figure 1) results in increased liver ceria levels (Figure 2), and that these changes in liver ceria are associated with evidence of liver pathology (Figures 3 and 4), decreases in liver weight (Table 1), and alterations in blood chemistry (Table 2). Consistent with other reports examining CeO2,15 titanium dioxide,16 silica,17 and copper18 nanoparticles, our data suggest it is possible that CeO2 nanoparticles are capable of translocating from the lung to the liver via the circulation. The histopathological appearance of the liver following CeO2 nanoparticle instillation is consistent with the possibility that ceria can induce several different pathological alterations, including hydropic degeneration of hepatocytes, enlargement of hepatocytes, dilatation of the sinusoids, and nuclear enlargement (Figures 3 and 4). There was no evidence of granuloma, portal inflammation, fibrosis, or bile duct abnormalities, except for the presence of some local inflammation of the lobules in some animals. Because the liver is the major organ for biotransformation of toxins, it may be the first organ to be exposed to nanoparticles that are able to enter into the circulation. It is thought that hydropic degeneration can be caused by hypoxia,19 ischemia,20 or the treatment of hepatocytes with endotoxins21 or chemicals.22 Consistent with our findings, this response has also been observed following exposure to other toxic materials, including copper nanoparticles23 and carbon tetrachloride,24 or following the inhalation of anesthetics such as sevofulrane and desflurane.25 How exposure to CeO2 nanoparticles may induce hydropic degeneration or if these changes are reversible is currently unclear. Sinusoidal dilatation is the increased gap between the hepatic cords in the hepatic lobule that has also been observed in aluminum-induced hepatic toxicity,26 carbon tetrachloride-induced hepatic toxicity,27 and ischemia,28 as well as with the organophosphate insecticide, methidathion. 29 In addition, we also noted the accumulation of granular material inside the hepatocytes which appeared to be dose-dependent and perhaps related to reduction of liver weight (Table 1). Our serum biochemical profile data suggest that CeO2 nanoparticle instillation in the rat may be associated with an elevation of alanine aminotransferase and reduction in albumin (Table 2). It is well established that hepatocyte damage is associated with the release of liver enzymes into the circulation and reduced albumin levels.26 In addition to changes in the level of circulating liver enzymes, CeO2 nanoparticle instillation also appears to decrease the sodium-potassium ratio and the amount of triglycerides (Table 2). Similar to other work examining other types of nanoparticles, 30,31 we observed a trend towards an increasing serum concentration of haptoglobin (16%), serum amyloid P protein (24%), and von Willebrand factor (33%) following exposure to CeO2 nanoparticles. Consistent with our histopathological findings, and the possibility of hepatic injury, we also found evidence that CeO2 nanoparticle instillation was associated with a trend toward increases in the amount of serum thrombopoietin, fibroblast growth factor, serum glutamic oxaloacetic transaminase, and transaminase thrombopoietin (Figure 4). Elevation in these serum biomarkers is thought to be highly correlated with acute hepatic injury.22,32 Taken together, these data suggest that ceria deposition may be associated with liver damage. Given our findings that CeO2 nanoparticle instillation, at least at the levels used in the current study, does not induce appreciable damage to the heart, kidney, or spleen. It is possible that the liver, by acting to clear CeO2 nanoparticles from the circulation, is functioning to prevent additional secondary or tertiary pathological changes elsewhere.

Conclusion

In summary, our data suggest that intratracheal instillation of CeO2 nanoparticles may be associated with hepatotoxicity. The toxicity induced by CeO2 nanoparticles appears to be dose-dependent, because the rats instilled with 7.0 mg/kg body weight of CeO2 nanoparticles exhibited the greatest evidence of toxicological response. The toxicological response appears to be limited to the liver and may occur through extrapulmonary translocation of the CeO2 nanoparticles into the systemic circulation. Given these findings, additional research to evaluate the health effects of CeO2 nanoparticles is likely warranted.
  32 in total

1.  Cerium oxide nanoparticle-induced pulmonary inflammation and alveolar macrophage functional change in rats.

Authors:  Jane Y Ma; Hongwen Zhao; Robert R Mercer; Mark Barger; Murali Rao; Terence Meighan; Diane Schwegler-Berry; Vincent Castranova; Joseph K Ma
Journal:  Nanotoxicology       Date:  2010-10-06       Impact factor: 5.913

2.  Auto-catalytic ceria nanoparticles offer neuroprotection to adult rat spinal cord neurons.

Authors:  Mainak Das; Swanand Patil; Neelima Bhargava; Jung-Fong Kang; Lisa M Riedel; Sudipta Seal; James J Hickman
Journal:  Biomaterials       Date:  2007-01-12       Impact factor: 12.479

3.  Cardioprotective effects of cerium oxide nanoparticles in a transgenic murine model of cardiomyopathy.

Authors:  Jianli Niu; Asim Azfer; Linda M Rogers; Xihai Wang; Pappachan E Kolattukudy
Journal:  Cardiovasc Res       Date:  2006-11-30       Impact factor: 10.787

4.  Effects of the exposure profile on the inhalation toxicity of carbon tetrachloride in male rats.

Authors:  M Bogers; L M Appelman; V J Feron; R B Beems; W R Notten
Journal:  J Appl Toxicol       Date:  1987-06       Impact factor: 3.446

5.  Systems toxicology used in nanotoxicology: mechanistic insights into the hepatotoxicity of nano-copper particles from toxicogenomics.

Authors:  BaoHua Yang; Quanjun Wang; RongHui Lei; ChunQi Wu; Chang Shi; QingXiu Wang; Ye Yuan; Ying Wang; YongWei Luo; ZhongHui Hu; Huazhi Ma; MingYang Liao
Journal:  J Nanosci Nanotechnol       Date:  2010-12

6.  Systematic influence induced by 3 nm titanium dioxide following intratracheal instillation of mice.

Authors:  Yufeng Li; Jungang Li; Jilei Yin; Wenxin Li; Cheng Kang; Qing Huang; Qingnuan Li
Journal:  J Nanosci Nanotechnol       Date:  2010-12

7.  Propolis prevents aluminium-induced genetic and hepatic damages in rat liver.

Authors:  Hasan Türkez; Mokhtar I Yousef; Fatime Geyikoglu
Journal:  Food Chem Toxicol       Date:  2010-07-14       Impact factor: 6.023

8.  The effects of subchronic methidathion toxicity on rat liver: role of antioxidant vitamins C and E.

Authors:  R Sutcu; I Altuntas; B Yildirim; N Karahan; H Demirin; N Delibas
Journal:  Cell Biol Toxicol       Date:  2006-05       Impact factor: 6.691

Review 9.  Cerium oxide nanoparticles prepared in self-assembled systems.

Authors:  Ali Bumajdad; Julian Eastoe; Asha Mathew
Journal:  Adv Colloid Interface Sci       Date:  2008-10-31       Impact factor: 12.984

10.  Comparative effects of curcumin and an analogue of curcumin in carbon tetrachloride-induced hepatotoxicity in rats.

Authors:  Narasimhanaidu Kamalakkannan; Rajagopalan Rukkumani; Penumathsa Suresh Varma; Periyasamy Viswanathan; Kallikat Narayanan Rajasekharan; Venugopal Padmanabhan Menon
Journal:  Basic Clin Pharmacol Toxicol       Date:  2005-07       Impact factor: 4.080

View more
  38 in total

Review 1.  Toxicological effect of engineered nanomaterials on the liver.

Authors:  A Kermanizadeh; B K Gaiser; H Johnston; D M Brown; V Stone
Journal:  Br J Pharmacol       Date:  2014-07-02       Impact factor: 8.739

2.  Beneficial effects of cerium oxide nanoparticles in development of chondrocyte-seeded hydrogel constructs and cellular response to interleukin insults.

Authors:  Sathish Ponnurangam; Grace D O'Connell; Irina V Chernyshova; Katherine Wood; Clark Tung-Hui Hung; Ponisseril Somasundaran
Journal:  Tissue Eng Part A       Date:  2014-06-25       Impact factor: 3.845

3.  Accumulation and trafficking of zinc oxide nanoparticles in an invertebrate model, Bombyx mori, with insights on their effects on immuno-competent cells.

Authors:  Ashiq Hussain Mir; Ayesha Qamar; Ishana Qadir; Alim H Naqvi; Rizwana Begum
Journal:  Sci Rep       Date:  2020-01-31       Impact factor: 4.379

4.  Hepatic alterations associated with fine particulate matter exposure.

Authors:  Iván Tavera Busso; Ana Carolina Mateos; Alicia González Peroni; Natalia Soledad Graziani; Hebe Alejandra Carreras
Journal:  Toxicol Res       Date:  2019-11-21

5.  Carbon Nanotubes Induced Fibrogenesis on Nanostructured Substrates.

Authors:  Kai Wang; Xiaoqing He; Will Linthicum; Ryan Mezan; Liying Wang; Yon Rojanasakul; Qi Wen; Yong Yang
Journal:  Environ Sci Nano       Date:  2017-01-30

6.  Induction of pulmonary fibrosis by cerium oxide nanoparticles.

Authors:  Jane Y Ma; Robert R Mercer; Mark Barger; Diane Schwegler-Berry; James Scabilloni; Joseph K Ma; Vincent Castranova
Journal:  Toxicol Appl Pharmacol       Date:  2012-05-18       Impact factor: 4.219

7.  Intravenous and gastric cerium dioxide nanoparticle exposure disrupts microvascular smooth muscle signaling.

Authors:  Valerie C Minarchick; Phoebe A Stapleton; Natalie R Fix; Stephen S Leonard; Edward M Sabolsky; Timothy R Nurkiewicz
Journal:  Toxicol Sci       Date:  2014-12-05       Impact factor: 4.849

8.  An in vivo and in vitro toxicological characterisation of realistic nanoscale CeO₂ inhalation exposures.

Authors:  Philip Demokritou; Samuel Gass; Georgios Pyrgiotakis; Joel M Cohen; William Goldsmith; Walt McKinney; David Frazer; Jane Ma; Diane Schwegler-Berry; Joseph Brain; Vincent Castranova
Journal:  Nanotoxicology       Date:  2012-11-08       Impact factor: 5.913

Review 9.  Health implications of engineered nanoparticles in infants and children.

Authors:  Song Tang; Mao Wang; Kaylyn E Germ; Hua-Mao Du; Wen-Jie Sun; Wei-Min Gao; Gregory D Mayer
Journal:  World J Pediatr       Date:  2015-08-08       Impact factor: 2.764

10.  Effects of amorphous silica coating on cerium oxide nanoparticles induced pulmonary responses.

Authors:  Jane Ma; Robert R Mercer; Mark Barger; Diane Schwegler-Berry; Joel M Cohen; Philip Demokritou; Vincent Castranova
Journal:  Toxicol Appl Pharmacol       Date:  2015-07-22       Impact factor: 4.219

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.