Literature DB >> 22057974

Ultrasonographic differentiation of malignant from benign breast lesions: a meta-analytic comparison of elasticity and BIRADS scoring.

Gelareh Sadigh1, Ruth C Carlos, Colleen H Neal, Ben A Dwamena.   

Abstract

There has been controversy regarding the accuracy of breast ultrasound elastography (USE) compared to conventional B-mode Ultrasound (USB). The purpose of this study was to conduct a direct comparative effectiveness analysis of USB versus USE or their combination in differentiating breast lesions through systematically reviewing recent literature. An extensive literature search of PubMed and other medical and general purpose databases from inception through August 2011 was conducted. Published studies that reported a direct comparison of the diagnostic performance of USE, using elasticity score versus USB, using breast imaging reporting and data system (BIRADS) for characterization of focal breast lesions were included. Summary diagnostic performance measures were assessed for each of the tests and their combination using bivariate generalized linear mixed modeling. The two tests were combined as: (1) conjunctive, where the outcome of the combination of tests is positive only if both test results are positive; (2) disjunctive, where the outcome of a combination of tests is negative only if both tests are negative. Twenty nine studies provided relevant information on 5,511 breast masses (2,065 cancers, 3,446 benign lesions). Sensitivity of USB, USE, and their conjunctive and disjunctive combinations were 96% (95% credible interval (CrI), 93-98%), 79% (95% CrI, 74-83%), 73% (95% CrI, 67-78%), and 99% (95% CrI, 98-99%), respectively. Specificity of USB, USE, and their conjunctive and disjunctive combinations were 70% (95% CrI, 55-83%), 88% (95% CrI, 82-92%), 97% (95% CrI, 95-99%), and 56% (95% CrI, 43-69%), respectively. The application of USE as a single test is not superior to USB alone. However, in low risk patients it is recommended to perform an USE following a positive USB result to decrease the rate of unnecessary biopsies.

Entities:  

Mesh:

Year:  2011        PMID: 22057974     DOI: 10.1007/s10549-011-1857-8

Source DB:  PubMed          Journal:  Breast Cancer Res Treat        ISSN: 0167-6806            Impact factor:   4.872


  27 in total

1.  Ultrasonographic findings of triple-negative breast cancer.

Authors:  Hai-Yan Du; Bao-Rong Lin; Du-Ping Huang
Journal:  Int J Clin Exp Med       Date:  2015-06-15

2.  The diagnostic importance of evaluation of solid breast masses by sonoelastography.

Authors:  Hasan Yerli; Tuğbahan Yılmaz; Banu Ural; Hüseyin Gülay
Journal:  Ulus Cerrahi Derg       Date:  2013-06-01

3.  Diagnosis of sub-centimetre breast lesions: combining BI-RADS-US with strain elastography and contrast-enhanced ultrasound-a preliminary study in China.

Authors:  Xiaoyun Xiao; Qiongchao Jiang; Huan Wu; Xiaofeng Guan; Wei Qin; Baoming Luo
Journal:  Eur Radiol       Date:  2016-10-19       Impact factor: 5.315

4.  Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography.

Authors:  Ji Hyun Youk; Hye Mi Gweon; Eun Ju Son; Jin Chung; Jeong-Ah Kim; Eun-Kyung Kim
Journal:  Eur Radiol       Date:  2012-12-02       Impact factor: 5.315

Review 5.  Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review.

Authors:  Rongrong Guo; Guolan Lu; Binjie Qin; Baowei Fei
Journal:  Ultrasound Med Biol       Date:  2017-10-26       Impact factor: 2.998

Review 6.  What scans we will read: imaging instrumentation trends in clinical oncology.

Authors:  Thomas Beyer; Luc Bidaut; John Dickson; Marc Kachelriess; Fabian Kiessling; Rainer Leitgeb; Jingfei Ma; Lalith Kumar Shiyam Sundar; Benjamin Theek; Osama Mawlawi
Journal:  Cancer Imaging       Date:  2020-06-09       Impact factor: 3.909

7.  Impact of breast mass size on accuracy of ultrasound elastography vs. conventional B-mode ultrasound: a meta-analysis of individual participants.

Authors:  Gelareh Sadigh; Ruth C Carlos; Colleen H Neal; Sebastian Wojcinski; Ben A Dwamena
Journal:  Eur Radiol       Date:  2012-10-20       Impact factor: 5.315

8.  Stiffness of the surrounding tissue of breast lesions evaluated by ultrasound elastography.

Authors:  JianQiao Zhou; WeiWei Zhan; YiJie Dong; ZhiFang Yang; Chun Zhou
Journal:  Eur Radiol       Date:  2014-04-05       Impact factor: 5.315

9.  Added value of strain elastography in the characterisation of breast lesions: A prospective study.

Authors:  Dimpi Sinha; Sukrity Sharma; Nischal G Kundaragi; Sudhir Kumar Kale
Journal:  Ultrasound       Date:  2020-03-16

10.  Ultrasound real-time elastography can predict malignancy in BI-RADS®-US 3 lesions.

Authors:  Sebastian Wojcinski; Esther Boehme; André Farrokh; Philipp Soergel; Friedrich Degenhardt; Peter Hillemanns
Journal:  BMC Cancer       Date:  2013-03-27       Impact factor: 4.430

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.