Literature DB >> 22051546

Paper-based chemiluminescence ELISA: lab-on-paper based on chitosan modified paper device and wax-screen-printing.

Shoumei Wang1, Lei Ge, Xianrang Song, Jinghua Yu, Shenguang Ge, Jiadong Huang, Fang Zeng.   

Abstract

A novel lab-on-paper device combining the simplicity and low-cost of microfluidic paper-based analytical devices (μPADs) and the sensitivity and selectivity of chemiluminescence ELISA (CL-ELISA) for the high-throughput, rapid, stable and reusable point-of-care testing is presented here. Chitosan was used to modify μPADs to covalently immobilize antibodies on μPADs. Thus, sandwich CL-ELISA on μPADs can be easily realized for further development of this technique in sensitive, specific and low-cost application. The paper device was fabricated by a low-cost, simple, and rapid wax-screen-printing method. Using tumor markers and paper microzone plate as model, the application test of this paper-based CL-ELISA was successfully performed with a linear range of 0.1-35.0 ng mL(-1) for α-fetoprotein, 0.5-80.0 U mL(-1) for cancer antigen 125 and 0.1-70.0 ng mL(-1) for carcinoembryonic antigen. Since the cutoff values of the three tumor markers in clinical diagnosis are 25 ng mL(-1), 35 U mL(-1) and 5 ng mL(-1), the sensitivity and linear ranges of the proposed method were enough for clinical application. In addition, this lab-on-paper immunodevice can provide reproducible results upon storage at 4 °C (sealed) for at least 5 weeks. Ultimately, this novel chitosan modification and wax-screen-printing methodology for μPADs can be readily translated to other signal reporting mechanism including electrochemiluminescence and photoelectrochemistry, and other receptors such as enzyme receptors and DNA receptors for determination of DNA, proteins and small molecules in point-of-care testing.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22051546     DOI: 10.1016/j.bios.2011.10.019

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  37 in total

1.  Automatic sequential fluid handling with multilayer microfluidic sample isolated pumping.

Authors:  Jixiao Liu; Hai Fu; Tianhang Yang; Songjing Li
Journal:  Biomicrofluidics       Date:  2015-10-01       Impact factor: 2.800

2.  Paper microzone plate based on DPPH as a simple colorimetric assay of the total antioxidant content of herbal extracts.

Authors:  Bambang Kuswandi; Muhammad Fantoni; Mochammad Amrun Hidayat; Indah Yulia Ningsih
Journal:  J Food Sci Technol       Date:  2020-04-03       Impact factor: 2.701

Review 3.  Biomarker detection for disease diagnosis using cost-effective microfluidic platforms.

Authors:  Sharma T Sanjay; Guanglei Fu; Maowei Dou; Feng Xu; Rutao Liu; Hao Qi; XiuJun Li
Journal:  Analyst       Date:  2015-11-07       Impact factor: 4.616

Review 4.  A review on advances in methods for modification of paper supports for use in point-of-care testing.

Authors:  Rui Hua Tang; Li Na Liu; Su Feng Zhang; Xiao Cong He; Xiu Jun Li; Feng Xu; Yong Hao Ni; Fei Li
Journal:  Mikrochim Acta       Date:  2019-07-09       Impact factor: 5.833

5.  Protein analytical assays for diagnosing, monitoring, and choosing treatment for cancer patients.

Authors:  Alicia D Powers; Sean P Palecek
Journal:  J Healthc Eng       Date:  2012-12       Impact factor: 2.682

Review 6.  Novel developments in mobile sensing based on the integration of microfluidic devices and smartphones.

Authors:  Ke Yang; Hagit Peretz-Soroka; Yong Liu; Francis Lin
Journal:  Lab Chip       Date:  2016-02-22       Impact factor: 6.799

Review 7.  A review on wax printed microfluidic paper-based devices for international health.

Authors:  S Altundemir; A K Uguz; K Ulgen
Journal:  Biomicrofluidics       Date:  2017-08-30       Impact factor: 2.800

8.  Paper-based chemiluminescence immunodevice for the carcinoembryonic antigen by employing multi-enzyme carbon nanosphere signal enhancement.

Authors:  Ying Chen; Weiru Chu; Wei Liu; Xiaoyan Guo; Yan Jin; Baoxin Li
Journal:  Mikrochim Acta       Date:  2018-02-19       Impact factor: 5.833

9.  Modification of a nitrocellulose membrane with cellulose nanofibers for enhanced sensitivity of lateral flow assays: application to the determination of Staphylococcus aureus.

Authors:  Rui Hua Tang; Li Na Liu; Su Feng Zhang; Ang Li; Zedong Li
Journal:  Mikrochim Acta       Date:  2019-11-22       Impact factor: 5.833

Review 10.  Paper-based analytical devices for clinical diagnosis: recent advances in the fabrication techniques and sensing mechanisms.

Authors:  Mazhar Sher; Rachel Zhuang; Utkan Demirci; Waseem Asghar
Journal:  Expert Rev Mol Diagn       Date:  2017-04       Impact factor: 5.225

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.