Evaluation of microgap size and microbial leakage in the connection area of 4 abutments with Straumann (ITI) implant.

Mansoor Rismanchian1, Mahnaz Hatami, Hamid Badrian, Navid Khalighinejad, Hossein Goroohi.   

Abstract

A microgap between implant and abutment can lead to mechanical and biological problems such as abutment screw fracture and peri-implantitis. The aim of this study was to evaluate microgap size and microbial leakage in the connection area of 4 different abutments to ITI implants. In this experimental study, 36 abutments in 4 groups (including Cast On, Castable, Solid, and Synocta abutments) connected to Straumann fixtures (with their inner part inoculated with bacterial suspension) and microbial leakage were assessed at different times. The size of the microgap in 4 randomized locations was then measured by scanning electron microscope. The data were analyzed by SPSS software and by 1-way variance statistical test, Kruskal-Wallis, and their supplementary tests (Mann-Whitney HSD and Tukey's; α = .05) at the next step. The effect of using different types of abutments was significant on the mean microgap size (P < .001) and on the mean number of leaked colonies (CFU/mL) through the connection area of the implant and abutment within the first 5 hours of the experiment (P = .012); however, it did not significantly influence microleakage at 24 hours, 48 hours, and 14 days (P = .145). Using Synocta abutments compared with Solid abutments will not provide us with more accommodation, and vice versa. Using Solid and Synocta abutments can significantly decrease the microgap size; however, Cast On abutments do not show a significant difference in terms of microgap compared with Castable abutments. Microleakage in the connection area is comparable for these 4 abutments.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22047449     DOI: 10.1563/AAID-JOI-D-11-00167

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  9 in total

Review 1.  Microleakage at the Different Implant Abutment Interface: A Systematic Review.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary; Shail Kumari
Journal:  J Clin Diagn Res       Date:  2017-06-01

2.  Mammalian cell response and bacterial adhesion on titanium healing abutments: effect of multiple implantation and sterilization cycles.

Authors:  Sanjana S Jain; Danyal A Siddiqui; Sutton E Wheelis; Kelli L Palmer; Thomas G Wilson; Danieli C Rodrigues
Journal:  Clin Oral Investig       Date:  2020-09-18       Impact factor: 3.573

3.  Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study.

Authors:  Pedro Molinero-Mourelle; Rocio Cascos-Sanchez; Burak Yilmaz; Walter Yu Hang Lam; Edmond Ho Nang Pow; Jaime Del Río Highsmith; Miguel Gómez-Polo
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

4.  Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B.

Authors:  Antoine Berberi; George Tehini; Khaldoun Rifai; Farah Bou Nasser Eddine; Bassam Badran; Haidar Akl
Journal:  J Dent Biomech       Date:  2014-08-11

5.  Peri-implant conditions and marginal bone loss around cemented and screw-retained single implant crowns in posterior regions: A retrospective cohort study with up to 4 years follow-up.

Authors:  Jun-Yu Shi; Long-Fei Zhuang; Xiao-Meng Zhang; Lin-Feng Fan; Hong-Chang Lai
Journal:  PLoS One       Date:  2018-02-05       Impact factor: 3.240

6.  Comparison of stresses in monoblock tilted implants and conventional angled multiunit abutment-implant connection systems in the all-on-four procedure.

Authors:  Özge Özdal Zincir; Ateş Parlar
Journal:  BMC Oral Health       Date:  2021-12-16       Impact factor: 2.757

7.  Antimicrobial Efficacy and Permeability of Various Sealing Materials in Two Different Types of Implant-Abutment Connections.

Authors:  Igor Smojver; Roko Bjelica; Marko Vuletić; Dražena Gerbl; Ana Budimir; Dragana Gabrić
Journal:  Int J Mol Sci       Date:  2022-07-21       Impact factor: 6.208

8.  In vitro evaluation of leakage at implant-abutment connection of three implant systems having the same prosthetic interface using rhodamine B.

Authors:  Antoine Berberi; Georges Tehini; Khaldoun Rifai; Farah Bou Nasser Eddine; Nabil El Zein; Bassam Badran; Haidar Akl
Journal:  Int J Dent       Date:  2014-05-11

9.  Antibacterial effect of nanocurcumin inside the implant fixture: An in vitro study.

Authors:  Ramin Negahdari; Mohammad Ali Ghavimi; Ali Barzegar; Mohammad Yousef Memar; Ladan Balazadeh; Sepideh Bohlouli; Simin Sharifi; Solmaz Maleki Dizaj
Journal:  Clin Exp Dent Res       Date:  2020-11-19
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.