Automated processing of whole blood units: operational value and in vitro quality of final blood components.

Marisa Jurado1, Manuel Algora, Félix Garcia-Sanchez, Santiago Vico, Eva Rodriguez, Sonia Perez, Luz Barbolla.   

Abstract

BACKGROUND: The Community Transfusion Centre in Madrid currently processes whole blood using a conventional procedure (Compomat, Fresenius) followed by automated processing of buffy coats with the OrbiSac system (CaridianBCT). The Atreus 3C system (CaridianBCT) automates the production of red blood cells, plasma and an interim platelet unit from a whole blood unit. Interim platelet unit are pooled to produce a transfusable platelet unit. In this study the Atreus 3C system was evaluated and compared to the routine method with regards to product quality and operational value.
MATERIALS AND METHODS: Over a 5-week period 810 whole blood units were processed using the Atreus 3C system. The attributes of the automated process were compared to those of the routine method by assessing productivity, space, equipment and staffing requirements. The data obtained were evaluated in order to estimate the impact of implementing the Atreus 3C system in the routine setting of the blood centre. Yield and in vitro quality of the final blood components processed with the two systems were evaluated and compared.
RESULTS: The Atreus 3C system enabled higher throughput while requiring less space and employee time by decreasing the amount of equipment and processing time per unit of whole blood processed. Whole blood units processed on the Atreus 3C system gave a higher platelet yield, a similar amount of red blood cells and a smaller volume of plasma. DISCUSSION: These results support the conclusion that the Atreus 3C system produces blood components meeting quality requirements while providing a high operational efficiency. Implementation of the Atreus 3C system could result in a large organisational improvement.

Mesh:

Year:  2011        PMID: 22044958      PMCID: PMC3258991          DOI: 10.2450/2011.0008-11

Source DB:  PubMed          Journal:  Blood Transfus        ISSN: 1723-2007            Impact factor:   3.443


  4 in total

1.  Fully automated processing of buffy coat-derived pooled concentrates.

Authors:  Luis Larrea; María Isabel Ortiz de Salazar; Roberto Roig; María Angeles Soler
Journal:  Transfusion       Date:  2005-04       Impact factor: 3.157

2.  Comparison of blood component preparation methods from whole blood bags based on buffy coat extraction.

Authors:  Joan Cid; Montse Claparols; Asunción Pinacho; José Manuel Hernández; Pilar Ortiz; Lluí S Puig; Ramon Pau Pla
Journal:  Transfus Apher Sci       Date:  2007-06-13       Impact factor: 1.764

3.  The OrbiSac system: results and organizational impact.

Authors:  Roberta Chicchi; Rino Biguzzi; Rita Santarelli
Journal:  Blood Transfus       Date:  2007-01       Impact factor: 3.443

4.  Fully automated processing of buffy-coat-derived pooled platelet concentrates.

Authors:  Karin Janetzko; Harald Klüter; Geert van Waeg; Hermann Eichler
Journal:  Transfusion       Date:  2004-07       Impact factor: 3.157

  4 in total
  1 in total

1.  Improvement of Blood Processing and Safety by Automation and Pathogen Reduction Technology.

Authors:  Ana Isabel Pérez Aliaga; Gorka Labata; Alfonso Aranda; Marcia Cardoso; Fernando Puente; José María Domingo; Carmen Garcés
Journal:  Transfus Med Hemother       Date:  2021-06-09       Impact factor: 3.747

  1 in total