Literature DB >> 22038328

Highly-integrated lab-on-chip system for point-of-care multiparameter analysis.

Soeren Schumacher1, Jörg Nestler, Thomas Otto, Michael Wegener, Eva Ehrentreich-Förster, Dirk Michel, Kai Wunderlich, Silke Palzer, Kai Sohn, Achim Weber, Matthias Burgard, Andrzej Grzesiak, Andreas Teichert, Albrecht Brandenburg, Birgit Koger, Jörg Albers, Eric Nebling, Frank F Bier.   

Abstract

A novel innovative approach towards a marketable lab-on-chip system for point-of-care in vitro diagnostics is reported. In a consortium of seven Fraunhofer Institutes a lab-on-chip system called "Fraunhofer ivD-platform" has been established which opens up the possibility for an on-site analysis at low costs. The system features a high degree of modularity and integration. Modularity allows the adaption of common and established assay types of various formats. Integration lets the system move from the laboratory to the point-of-need. By making use of the microarray format the lab-on-chip system also addresses new trends in biomedicine. Research topics such as personalized medicine or companion diagnostics show that multiparameter analyses are an added value for diagnostics, therapy as well as therapy control. These goals are addressed with a low-cost and self-contained cartridge, since reagents, microfluidic actuators and various sensors are integrated within the cartridge. In combination with a fully automated instrumentation (read-out and processing unit) a diagnostic assay can be performed in about 15 min. Via a user-friendly interface the read-out unit itself performs the assay protocol, data acquisition and data analysis. So far, example assays for nucleic acids (detection of different pathogens) and protein markers (such as CRP and PSA) have been established using an electrochemical read-out based on redoxcycling or an optical read-out based on total internal reflectance fluorescence (TIRF). It could be shown that the assay performance within the cartridge is similar to that found for the same assay in a microtiter plate. Furthermore, recent developments are the integration of sample preparation and polymerase chain reaction (PCR) on-chip. Hence, the instrument is capable of providing heating-and-cooling cycles necessary for DNA-amplification. In addition to scientific aspects also the production of such a lab-on-chip system was part of the development since this heavily affects the success of a later market launch. In summary, the Fraunhofer ivD-platform covers the whole value chain ranging from microfluidics, material and polymer sciences, assay and sensor development to the production and assembly design. In this consortium the gap between diagnostic needs and available technologies can be closed.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22038328     DOI: 10.1039/c1lc20693a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  33 in total

1.  Integration of programmable microfluidics and on-chip fluorescence detection for biosensing applications.

Authors:  J W Parks; M A Olson; J Kim; D Ozcelik; H Cai; R Carrion; J L Patterson; R A Mathies; A R Hawkins; H Schmidt
Journal:  Biomicrofluidics       Date:  2014-09-30       Impact factor: 2.800

Review 2.  Advances in microfluidic materials, functions, integration, and applications.

Authors:  Pamela N Nge; Chad I Rogers; Adam T Woolley
Journal:  Chem Rev       Date:  2013-02-14       Impact factor: 60.622

Review 3.  Toward integrated molecular diagnostic system (i MDx): principles and applications.

Authors:  Seung-Min Park; Andrew F Sabour; Jun Ho Son; Sang Hun Lee; Luke P Lee
Journal:  IEEE Trans Biomed Eng       Date:  2014-05       Impact factor: 4.538

4.  Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy.

Authors:  Alon Greenbaum; Wei Luo; Ting-Wei Su; Zoltán Göröcs; Liang Xue; Serhan O Isikman; Ahmet F Coskun; Onur Mudanyali; Aydogan Ozcan
Journal:  Nat Methods       Date:  2012-08-30       Impact factor: 28.547

5.  UV activation of polymeric high aspect ratio microstructures: ramifications in antibody surface loading for circulating tumor cell selection.

Authors:  Joshua M Jackson; Małgorzata A Witek; Mateusz L Hupert; Charles Brady; Swathi Pullagurla; Joyce Kamande; Rachel D Aufforth; Christopher J Tignanelli; Robert J Torphy; Jen Jen Yeh; Steven A Soper
Journal:  Lab Chip       Date:  2014-01-07       Impact factor: 6.799

Review 6.  Advances in Candida detection platforms for clinical and point-of-care applications.

Authors:  Mohammadali Safavieh; Chad Coarsey; Nwadiuto Esiobu; Adnan Memic; Jatin Mahesh Vyas; Hadi Shafiee; Waseem Asghar
Journal:  Crit Rev Biotechnol       Date:  2016-04-19       Impact factor: 8.429

Review 7.  On-chip biomedical imaging.

Authors:  Zoltán Göröcs; Aydogan Ozcan
Journal:  IEEE Rev Biomed Eng       Date:  2013

Review 8.  Evanescent wave fluorescence biosensors: Advances of the last decade.

Authors:  Chris Rowe Taitt; George P Anderson; Frances S Ligler
Journal:  Biosens Bioelectron       Date:  2015-07-20       Impact factor: 10.618

9.  Hydrogel-coated microfluidic channels for cardiomyocyte culture.

Authors:  Nasim Annabi; Šeila Selimović; Juan Pablo Acevedo Cox; João Ribas; Mohsen Afshar Bakooshli; Déborah Heintze; Anthony S Weiss; Donald Cropek; Ali Khademhosseini
Journal:  Lab Chip       Date:  2013-09-21       Impact factor: 6.799

Review 10.  Innovative and rapid antimicrobial susceptibility testing systems.

Authors:  Alex van Belkum; Carey-Ann D Burnham; John W A Rossen; Frederic Mallard; Olivier Rochas; William Michael Dunne
Journal:  Nat Rev Microbiol       Date:  2020-02-13       Impact factor: 60.633

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.