Literature DB >> 22030102

Comparative evaluation of the Vitek-2 Compact and Phoenix systems for rapid identification and antibiotic susceptibility testing directly from blood cultures of Gram-negative and Gram-positive isolates.

Giovanni Gherardi1, Silvia Angeletti, Miriam Panitti, Arianna Pompilio, Giovanni Di Bonaventura, Francesca Crea, Alessandra Avola, Laura Fico, Carlo Palazzo, Genoveffa Francesca Sapia, Daniela Visaggio, Giordano Dicuonzo.   

Abstract

We performed a comparative evaluation of the Vitek-2 Compact and Phoenix systems for direct identification and antimicrobial susceptibility testing (AST) from positive blood culture bottles in comparison to the standard methods. Overall, 139 monomicrobial blood cultures, comprising 91 Gram-negative and 48 Gram-positive isolates, were studied. Altogether, 100% and 92.3% of the Gram-negative isolates and 75% and 43.75% of the Gram-positive isolates showed concordant identification between the direct and the standard methods with Vitek and Phoenix, respectively. AST categorical agreements of 98.7% and 99% in Gram-negative and of 96.2% and 99.5% in Gram-positive isolates with Vitek and Phoenix, respectively, were observed. In conclusion, direct inoculation procedures for Gram-negative isolates showed an excellent performance with both automated systems, while for identification of Gram-positive isolates they proved to be less reliable, although Vitek provided acceptable results. This approach contributes to reducing the turnaround time to result of blood cultures, with a positive impact on patient care.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22030102     DOI: 10.1016/j.diagmicrobio.2011.09.015

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  36 in total

1.  Strategy for rapid identification and antibiotic susceptibility testing of gram-negative bacteria directly recovered from positive blood cultures using the Bruker MALDI Biotyper and the BD Phoenix system.

Authors:  Jana L Wimmer; S Wesley Long; Patricia Cernoch; Geoffrey A Land; James R Davis; James M Musser; Randall J Olsen
Journal:  J Clin Microbiol       Date:  2012-04-18       Impact factor: 5.948

Review 2.  Matrix-assisted laser desorption ionization-time of flight mass spectrometry: a fundamental shift in the routine practice of clinical microbiology.

Authors:  Andrew E Clark; Erin J Kaleta; Amit Arora; Donna M Wolk
Journal:  Clin Microbiol Rev       Date:  2013-07       Impact factor: 26.132

3.  Antimicrobial susceptibility testing of Gram-positive and -negative bacterial isolates directly from spiked blood culture media with Raman spectroscopy.

Authors:  H E Dekter; C C Orelio; M C Morsink; S Tektas; B Vis; R Te Witt; W B van Leeuwen
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2016-09-08       Impact factor: 3.267

4.  Direct disk diffusion test using European Clinical Antimicrobial Susceptibility Testing breakpoints provides reliable results compared with the standard method.

Authors:  Sofia Stokkou; Gernot Geginat; Dirk Schlüter; Ina Tammer
Journal:  Eur J Microbiol Immunol (Bp)       Date:  2015-03-26

5.  Whole-genome sequencing of Klebsiella pneumoniae MDR strain isolated in a Syrian refugee.

Authors:  Silvia Angeletti; Eleonora Cella; Alessia Lai; Alessandra Lo Presti; Francesca Antonelli; Alessia Conti; Maurizio Lopalco; Silvia Spoto; Gianguglielmo Zehender; Massimo Ciccozzi
Journal:  Pathog Glob Health       Date:  2017-04-12       Impact factor: 2.894

6.  Blood Culture Turnaround Time in U.S. Acute Care Hospitals and Implications for Laboratory Process Optimization.

Authors:  Ying P Tabak; Latha Vankeepuram; Gang Ye; Kay Jeffers; Vikas Gupta; Patrick R Murray
Journal:  J Clin Microbiol       Date:  2018-11-27       Impact factor: 5.948

7.  Real-time optical antimicrobial susceptibility testing.

Authors:  Marlene Fredborg; Klaus R Andersen; Erik Jørgensen; Aida Droce; Tom Olesen; Bent B Jensen; Flemming S Rosenvinge; Teis E Sondergaard
Journal:  J Clin Microbiol       Date:  2013-04-17       Impact factor: 5.948

8.  Acceleration of antimicrobial susceptibility testing of positive blood cultures by inoculation of Vitek 2 cards with briefly incubated solid medium cultures.

Authors:  Evgeny A Idelevich; Isabel Schüle; Barbara Grünastel; Jörg Wüllenweber; Georg Peters; Karsten Becker
Journal:  J Clin Microbiol       Date:  2014-08-27       Impact factor: 5.948

9.  Impact of rapid diagnosis of Staphylococcus aureus bacteremia from positive blood cultures on patient management.

Authors:  M P Romero-Gómez; E Cendejas-Bueno; J García Rodriguez; J Mingorance
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2017-08-23       Impact factor: 3.267

10.  Emerging Microtechnologies and Automated Systems for Rapid Bacterial Identification and Antibiotic Susceptibility Testing.

Authors:  Yiyan Li; Xing Yang; Weian Zhao
Journal:  SLAS Technol       Date:  2017-08-29       Impact factor: 3.047

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.