Literature DB >> 22029044

Gold nanorods-based FRET assay for sensitive detection of Pb2+ using 8-17DNAzyme.

Lin Wang1, Yan Jin, Jing Deng, Guozhen Chen.   

Abstract

In this paper, we have reported a sensitive assay for fluorescence "turn-on" detection of Pb(2+) in aqueous solutions based on FRET between gold nanorods (GNRs) and the FAM-labeled substrate strand of 8-17DNAzyme. The fluorescence of the FAM-labeled substrate strand is quenched when 8-17DNAzyme is adsorbed on GNRs surface through electrostatic interaction. In the presence of lead ions, the fluorescence is restored due to the decrease of FRET efficiency caused by the specific cleavage of the FAM-labeled substrate strand by the enzyme, which weakens the electrostatic interaction between the GNRs and short FAM-labeled DNA fragment. The interference of eleven common metal ions has been tested, indicating that Pb(2+) can be selectively detected. This method exhibits a high sensitivity for Pb(2+) with a detection limit of 61.8 pM and a linear range from 0.1 nM to 100 nM. It is a simple, sensitive, and selective method for Pb(2+) detection. Moreover, this sensing system obtained satisfying results for Pb(2+) detection in tap water samples.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22029044     DOI: 10.1039/c1an15783c

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  8 in total

1.  Fluorescent nanoprobes for sensing and imaging of metal ions: recent advances and future perspectives.

Authors:  JingJing Zhang; FangFang Cheng; JingJing Li; Jun-Jie Zhu; Yi Lu
Journal:  Nano Today       Date:  2016-06-11       Impact factor: 20.722

Review 2.  Fluorescent sensors for measuring metal ions in living systems.

Authors:  Kyle P Carter; Alexandra M Young; Amy E Palmer
Journal:  Chem Rev       Date:  2014-03-03       Impact factor: 60.622

Review 3.  DNA as sensors and imaging agents for metal ions.

Authors:  Yu Xiang; Yi Lu
Journal:  Inorg Chem       Date:  2013-12-20       Impact factor: 5.165

4.  Fluorometric determination of lead(II) and mercury(II) based on their interaction with a complex formed between graphene oxide and a DNAzyme.

Authors:  Ayyanu Ravikumar; Perumal Panneerselvam; Kothalam Radhakrishnan
Journal:  Mikrochim Acta       Date:  2017-12-01       Impact factor: 5.833

5.  Identifying the Stoichiometry of Metal/Ligand Complex by Coupling Spectroscopy and Modelling: a Comprehensive Study on Two Fluorescent Molecules Specific to Lead.

Authors:  William René; Madjid Arab; Katri Laatikainen; Stéphane Mounier; Catherine Branger; Véronique Lenoble
Journal:  J Fluoresc       Date:  2019-07-13       Impact factor: 2.217

Review 6.  Visualizing metal ions in cells: an overview of analytical techniques, approaches, and probes.

Authors:  Kevin M Dean; Yan Qin; Amy E Palmer
Journal:  Biochim Biophys Acta       Date:  2012-04-13

7.  Signal-on fluorescent sensing strategy for Pb2+ detection based on 8-17 DNAzyme-mediated molecular beacon-type catalytic hairpin assembly circuit.

Authors:  Junyang Wang; Zheng Liu; Ying Li; Chuanyu Yang; Xinyue Ma; Hongxia Li; Chunyan Sun
Journal:  Anal Bioanal Chem       Date:  2022-07-13       Impact factor: 4.478

8.  A "Turn-On" Fluorescence Copper Biosensor Based on DNA Cleavage-Dependent Graphene Oxide-dsDNA-CdTe Quantum Dots Complex.

Authors:  Liyun Ding; Bing Xu; Tao Li; Jun Huang; Wei Bai
Journal:  Sensors (Basel)       Date:  2018-08-09       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.