Literature DB >> 22027261

Patient-specific three-dimensional concomitant dose from cone beam computed tomography exposure in image-guided radiotherapy.

Emiliano Spezi1, Patrick Downes, Richard Jarvis, Emil Radu, John Staffurth.   

Abstract

PURPOSE: The purpose of the present study was to quantify the concomitant dose received by patients undergoing cone beam computed tomography (CBCT) scanning in different clinical scenarios as a part of image-guided radiotherapy (IGRT) procedures. METHODS AND MATERIALS: We calculated the three-dimensional concomitant dose received as a result of CBCT scans in 6 patients representing different clinical scenarios: two pelvis, two head and neck, and two chest. We assessed the effect that a daily on-line IGRT strategy would have on the patient dose distribution, assuming 40 CBCT scans throughout the treatment course. The additional dose to the planning target volume margin region was also estimated.
RESULTS: In the pelvis, a single CBCT scan delivered a mean dose to the femoral heads of 2-6 cGy and the rectum of 1-2 cGy. An additional dose to the planning target volume was within 1-3 cGy. In the chest, the mean dose to the planning target volume varied from 2.5 to 5 cGy. The lung and spinal cord planning organ at risk volume received ≤4 cGy and ≤5 cGy, respectively. In the head and neck, a single CBCT scan delivered a mean dose of 0.3 cGy, with bony structures receiving 0.5-0.8 cGy. The femoral heads received an additional dose of 1.5-2.5 Gy. A reduction of 20-30% in the mean dose to the organs at risk was achieved using bowtie filtration. In the head and neck, the dose to the eyes and brainstem was eliminated by decreasing the craniocaudal field size.
CONCLUSIONS: The additional dose from on-line IGRT procedures can be clinically relevant. The organ dose can be significantly reduced with the use of appropriate patient-specific settings. The concomitant dose from CBCT should be accounted for and the acquisition settings optimized for optimal IGRT strategies on a patient basis.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22027261     DOI: 10.1016/j.ijrobp.2011.06.1972

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  18 in total

1.  Volumetric image-guided highly conformal radiotherapy of the prostate bed: Toxicity analysis.

Authors:  Gianluca Ingrosso; Alessandra Carosi; Daniela di Cristino; Elisabetta Ponti; Andrea Lancia; Alessandra Murgia; Claudia Bruni; Pasquale Morelli; Franca Pietrasanta; Riccardo Santoni
Journal:  Rep Pract Oncol Radiother       Date:  2016-11-24

2.  Investigation into the radiobiological consequences of pre-treatment verification imaging with megavoltage X-rays in radiotherapy.

Authors:  W B Hyland; S J McMahon; K T Butterworth; A J Cole; R B King; K M Redmond; K M Prise; A R Hounsell; C K McGarry
Journal:  Br J Radiol       Date:  2014-02-03       Impact factor: 3.039

3.  Image quality and dose distributions of three linac-based imaging modalities.

Authors:  Yvonne Dzierma; Evemarie Ames; Frank Nuesken; Jan Palm; Norbert Licht; Christian Rübe
Journal:  Strahlenther Onkol       Date:  2014-12-20       Impact factor: 3.621

4.  Image-guided radiotherapy of the prostate using daily CBCT: the feasibility and likely benefit of implementing a margin reduction.

Authors:  I F Maund; R J Benson; J Fairfoul; J Cook; R Huddart; A Poynter
Journal:  Br J Radiol       Date:  2014-10-29       Impact factor: 3.039

5.  Construction of Prediction Model of Radiotherapy Set-Up Errors in Patients with Lung Cancer.

Authors:  Fan Yang; Xinxia Li
Journal:  Biomed Res Int       Date:  2022-06-25       Impact factor: 3.246

6.  Accounting for patient size in the optimization of dose and image quality of pelvis cone beam CT protocols on the Varian OBI system.

Authors:  Tim J Wood; Craig S Moore; Carl J Horsfield; John R Saunderson; Andrew W Beavis
Journal:  Br J Radiol       Date:  2015-09-30       Impact factor: 3.039

7.  Estimation of effective imaging dose for kilovoltage intratreatment monitoring of the prostate position during cancer radiotherapy.

Authors:  J A Ng; J Booth; P Poulsen; Z Kuncic; P J Keall
Journal:  Phys Med Biol       Date:  2013-08-12       Impact factor: 3.609

8.  Commissioning kilovoltage cone-beam CT beams in a radiation therapy treatment planning system.

Authors:  Parham Alaei; Emiliano Spezi
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

9.  Investigation of the radiation dose from cone-beam CT for image-guided radiotherapy: A comparison of methodologies.

Authors:  Jarryd G Buckley; Dean Wilkinson; Alessandra Malaroda; Peter Metcalfe
Journal:  J Appl Clin Med Phys       Date:  2017-12-19       Impact factor: 2.102

10.  Measurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques.

Authors:  Sudesh Deshpande; Deepak Dhote; Kalpna Thakur; Amol Pawar; Rajesh Kumar; Munish Kumar; M S Kulkarni; S D Sharma; V Kannan
Journal:  J Med Phys       Date:  2016 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.