Literature DB >> 22027119

Determination of copper(II) in the dairy product by an electrochemical sensor based on click chemistry.

Suyan Qiu1, Lidan Xie, Sen Gao, Qida Liu, Zhenyu Lin, Bin Qiu, Guonan Chen.   

Abstract

Herein, a novel sensitive electrochemical sensor for copper(II) based on Cu(I) catalyzed alkyne-azide cycloaddition reaction (CuAAC) is described. The catalyst of Cu(I) species is derived from electrochemical reduction of Cu(II) through bulk electrolysis (BE) with coulometry technique. The propargyl-functionalized ferrocene (propargyl-functionalized Fc) is covalently coupled onto the electrode surface via CuAAC reaction and forms propargyl-functionalized Fc modified gold electrode, which allows a good and stable electrochemical signal. The change of current at peak (dI), detected by differential pulse voltammetry (DPV), exhibits a linear response to the logarithm of Cu(II) concentration in the range of 1.0×10(-14)-1.0×10(-9) mol L(-1). It is also found that the proposed sensor has a good selectivity for copper(II) assay even in the presence of other common metal ions. Additionally, the proposed method has been applied to determine copper(II) in the dairy product (yoghurt) with satisfactory results.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22027119     DOI: 10.1016/j.aca.2011.09.013

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Coumarin Based Highly Selective "off-on-off" Type Novel Fluorescent Sensor for Cu2+ and S2- in Aqueous Solution.

Authors:  Şükriye Nihan Karuk Elmas; Furkan Ozen; Kenan Koran; Ibrahim Yilmaz; Ahmet Orhan Gorgulu; Serkan Erdemir
Journal:  J Fluoresc       Date:  2016-12-19       Impact factor: 2.217

2.  Signal-Amplified Lateral Flow Test Strip for Visual Detection of Cu2.

Authors:  Yulong Wang; Limin Wang; Juanjuan Xue; Jinbo Dong; Jia Cai; Xiude Hua; Minghua Wang; Cunzheng Zhang; Fengquan Liu
Journal:  PLoS One       Date:  2017-01-10       Impact factor: 3.240

3.  Improving the Voltammetric Determination of Hg(II): A Comparison Between Ligand-Modified Glassy Carbon and Electrochemically Reduced Graphene Oxide Electrodes.

Authors:  Matei D Raicopol; Andreea M Pandele; Constanţa Dascălu; Eugeniu Vasile; Anamaria Hanganu; Gabriela-Geanina Vasile; Ioana Georgiana Bugean; Cristian Pirvu; Gabriela Stanciu; George-Octavian Buica
Journal:  Sensors (Basel)       Date:  2020-11-28       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.