Literature DB >> 22026628

Using arterial pressure waveform analysis for the assessment of fluid responsiveness.

Maxime Cannesson1, Daniel de Backer, Christoph K Hofer.   

Abstract

Predicting the effects of volume expansion on cardiac output and oxygen delivery is of major importance in different clinical scenarios. Functional hemodynamic parameters based on pulse waveform analysis, which are relying on the effects of mechanical ventilation on stroke volume and its surrogates, have been shown to be reliable predictors of fluid responsiveness during anesthesia and intensive care unit treatment, as demonstrated by several clinical studies and meta-analyses. However, different limitations of these parameters have to be considered when they are used in clinical practice. Today, they can be continuously and automatically monitored by a variety of commercially available devices. These parameters have been introduced into the concept of perioperative fluid management and hemodynamic optimization - an approach that may positively impact postoperative patients' outcomes. In this article, technical aspects of the assessment of the functional hemodynamic parameters derived from pulse waveform analysis are summarized, emphasizing their advantages, limitations and potential applications, primarily in a perioperative setting in order to improve patient outcome.

Entities:  

Mesh:

Year:  2011        PMID: 22026628     DOI: 10.1586/erd.11.30

Source DB:  PubMed          Journal:  Expert Rev Med Devices        ISSN: 1743-4440            Impact factor:   3.166


  5 in total

Review 1.  Accuracy of pleth variability index to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis.

Authors:  Haitao Chu; Yong Wang; Yanfei Sun; Gang Wang
Journal:  J Clin Monit Comput       Date:  2015-08-05       Impact factor: 2.502

2.  Control-oriented physiological modeling of hemodynamic responses to blood volume perturbation.

Authors:  Ramin Bighamian; Bahram Parvinian; Christopher G Scully; George Kramer; Jin-Oh Hahn
Journal:  Control Eng Pract       Date:  2018-03-14       Impact factor: 3.475

3.  Automated stroke volume and pulse pressure variations predict fluid responsiveness in mechanically ventilated patients with obstructive jaundice.

Authors:  Feng Zhao; Peng Wang; Shujun Pei; Weidong Mi; Qiang Fu
Journal:  Int J Clin Exp Med       Date:  2015-11-15

4.  Reliability of pleth variability index in predicting preload responsiveness of mechanically ventilated patients under various conditions: a systematic review and meta-analysis.

Authors:  Tianyu Liu; Chao Xu; Min Wang; Zheng Niu; Dunyi Qi
Journal:  BMC Anesthesiol       Date:  2019-05-08       Impact factor: 2.217

5.  The plethysmographic variability index does not predict fluid responsiveness estimated by esophageal Doppler during kidney transplantation: A controlled study.

Authors:  Morgan Le Guen; Arnaud Follin; Etienne Gayat; Marc Fischler
Journal:  Medicine (Baltimore)       Date:  2018-05       Impact factor: 1.889

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.