Literature DB >> 22025217

Evaluation of a 2D detector array for patient-specific VMAT QA with different setups.

Ramesh Boggula1, Mattias Birkner, Frank Lohr, Volker Steil, Frederik Wenz, Hansjoerg Wertz.   

Abstract

For pre-treatment plan verification of advanced treatment techniques such as intensity-modulated arc therapy, a fast and reliable dosimetric device is required. In this study, we investigated the suitability of MatriXX in different setups for verification of volumetric modulated arc therapy (VMAT) plans. If MatriXX is used in a stationary phantom (MULTICube), the measured dose is dependent on the beam angle. For the first setup (MatriXX/MULTICube), we developed correction factors (CFs) for each detector element (1020 CFs). We investigated the accuracy of these CFs by verifying 12 VMAT plans. In the second setup, we also assessed the suitability of MatriXX in a dedicated holder. Using this setup (MatriXX/Holder), 30 additional VMAT plans were verified. Deviations of up to ∼17% and ∼11% were noted for one of the ion chambers at 90° and 180° gantry positions. The influence of the beam angle dependence (MULTICube) can explicitly be seen when a gamma criterion of 2%/2 mm was chosen. An overall improvement of 4.3% of passing pixels (pp) was noted after applying beam angular-dependent CFs. When the gamma criterion was 3%/3 mm, the %pp was ≥ 95% without and ∼100% with correction. With the second setup, MatriXX/holder, we showed excellent agreement between measurements and calculations. The %pp averaged over all plans (30 VMAT treatment plans) was nearly ∼100%. The combination of MatriXX with MULTICube or with holder proved to be a fast and reliable method for pretreatment verification of arc therapy with sufficient accuracy.

Entities:  

Mesh:

Year:  2011        PMID: 22025217     DOI: 10.1088/0031-9155/56/22/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  [Image-guided radiation therapy. Paradigm change in radiation therapy].

Authors:  F Wenz; C Belka; M Reiser; S O Schönberg
Journal:  Radiologe       Date:  2012-03       Impact factor: 0.635

2.  Evaluation of a commercial orthopaedic metal artefact reduction tool in radiation therapy of patients with head and neck cancer.

Authors:  H Kwon; K S Kim; Y M Chun; H-G Wu; J N K Carlson; J M Park; J-I Kim
Journal:  Br J Radiol       Date:  2015-05-20       Impact factor: 3.039

3.  Advantage of 3D volumetric dosemeter in delivery quality assurance of dynamic arc therapy: comparison of pencil beam and Monte Carlo calculations.

Authors:  H-J Shin; J H Song; J-Y Jung; Y-K Kwak; C S Kay; Y-N Kang; B O Choi; H S Jang; S H Son
Journal:  Br J Radiol       Date:  2013-11-14       Impact factor: 3.039

4.  Quality assurance of TomoDirect treatment plans using I'mRT MatriXX.

Authors:  Cw Kong; Sk Yu; Ky Cheung; H Geng; Yw Ho; Ww Lam; Wk Wong
Journal:  Biomed Imaging Interv J       Date:  2012-04-01

5.  Assessment of Imprecise Small Photon Beam Modeling by Two Treatment Planning System Algorithms.

Authors:  Hadi Keivan; Daryoush Shahbazi-Gahrouei; Ahmad Shanei; Alireza Amouheidari
Journal:  J Med Signals Sens       Date:  2018 Jan-Mar

6.  Dosimetric validation and clinical implementation of two 3D dose verification systems for quality assurance in volumetric-modulated arc therapy techniques.

Authors:  Francisco Clemente-Gutiérrez; Consuelo Pérez-Vara
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

7.  Electronic Portal Imaging Device-Based Three-Dimensional Volumetric Dosimetry for Intensity-modulated Radiotherapy Pretreatment Quality Assurance.

Authors:  Manikandan Arjunan; Sureka Chandra Sekaran; Biplab Sarkar; Saran Kumar Manavalan
Journal:  J Med Phys       Date:  2019 Jul-Sep

8.  Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom.

Authors:  Masao Tanooka; Hiroshi Doi; Hideharu Miura; Hiroyuki Inoue; Yasue Niwa; Yasuhiro Takada; Masayuki Fujiwara; Toshiyuki Sakai; Kiyoshi Sakamoto; Norihiko Kamikonya; Shozo Hirota
Journal:  J Radiat Res       Date:  2013-05-17       Impact factor: 2.724

9.  Angular dependence correction of MatriXX and its application to composite dose verification.

Authors:  Yoshinobu Shimohigashi; Fujio Araki; Hirofumi Tominaga; Junichi Sakata; Keiichi Kawasaki; Nagisa Kanetake; Yuki Iwashita; Saori Yoshimura; Tamami Kawakami; Terunobu Ishihara; Tomoko Okuda; Kasei Kogo
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

10.  Commissioning results of an automated treatment planning verification system.

Authors:  Christopher L Nelson; Bryan E Mason; Ronald C Robinson; Kelly D Kisling; Steven M Kirsner
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.