Literature DB >> 22024474

Backscatter factors and mass energy-absorption coefficient ratios for diagnostic radiology dosimetry.

Hamza Benmakhlouf1, Hugo Bouchard, Annette Fransson, Pedro Andreo.   

Abstract

Backscatter factors, B, and mass energy-absorption coefficient ratios, (μ(en)/ρ)(w, air), for the determination of the surface dose in diagnostic radiology were calculated using Monte Carlo simulations. The main purpose was to extend the range of available data to qualities used in modern x-ray techniques, particularly for interventional radiology. A comprehensive database for mono-energetic photons between 4 and 150 keV and different field sizes was created for a 15 cm thick water phantom. Backscattered spectra were calculated with the PENELOPE Monte Carlo system, scoring track-length fluence differential in energy with negligible statistical uncertainty; using the Monte Carlo computed spectra, B factors and (μ(en)/ρ)(w, air) were then calculated numerically for each energy. Weighted averaging procedures were subsequently used to convolve incident clinical spectra with mono-energetic data. The method was benchmarked against full Monte Carlo calculations of incident clinical spectra obtaining differences within 0.3-0.6%. The technique used enables the calculation of B and (μ(en)/ρ)(w, air) for any incident spectrum without further time-consuming Monte Carlo simulations. The adequacy of the extended dosimetry data to a broader range of clinical qualities than those currently available, while keeping consistency with existing data, was confirmed through detailed comparisons. Mono-energetic and spectra-averaged values were compared with published data, including those in ICRU Report 74 and IAEA TRS-457, finding average differences of 0.6%. Results are provided in comprehensive tables appropriated for clinical use. Additional qualities can easily be calculated using a designed GUI interface in conjunction with software to generate incident photon spectra.

Entities:  

Mesh:

Year:  2011        PMID: 22024474     DOI: 10.1088/0031-9155/56/22/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Monte Carlo investigation of backscatter point spread function for X-ray imaging examinations.

Authors:  Zhenyu Xiong; Sarath Vijayan; Stephen Rudin; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

2.  Calculation of the entrance skin dose distribution for fluoroscopically guided interventions using a pencil beam backscatter model.

Authors:  Sarath Vijayan; Zhenyu Xiong; Stephen Rudin; Daniel R Bednarek
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-14

3.  Practical alignment method for X-ray spectral measurement in micro-CT system based on 3D printing technology.

Authors:  Liqiang Ren; Di Wu; Yuhua Li; Bin Zheng; Yong Chen; Kai Yang; Hong Liu
Journal:  Biomed Phys Eng Express       Date:  2016-07-15

4.  Skin dose mapping for non-uniform x-ray fields using a backscatter point spread function.

Authors:  Sarath Vijayan; Zhenyu Xiong; Alok Shankar; Stephen Rudin; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

5.  Vendor-independent skin dose mapping application for interventional radiology and cardiology.

Authors:  Marko Krajinović; Nikola Kržanović; Olivera Ciraj-Bjelac
Journal:  J Appl Clin Med Phys       Date:  2021-01-13       Impact factor: 2.102

6.  A high-resolution dose calculation engine for X-ray microbeams radiation therapy.

Authors:  Sarvenaz Keshmiri; Sylvan Brocard; Raphaël Serduc; Jean-François Adam
Journal:  Med Phys       Date:  2022-04-12       Impact factor: 4.506

7.  Investigation of the clinical performance of a novel solid-state diagnostic dosimeter.

Authors:  Jason Tse; Donald McLean
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

  7 in total