Literature DB >> 22018366

Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens.

Gonzalo Muñoz1, César Albarrán-Diego, Teresa Ferrer-Blasco, Hani F Sakla, Santiago García-Lázaro.   

Abstract

PURPOSE: To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL).
SETTING: Private practice surgery center, Valencia, Spain.
DESIGN: Cohort study.
METHODS: Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; defocus curves; and a quality-of-vision questionnaire, including presence of halos or dysphotopsia, were evaluated 6 months postoperatively. A control group of age-matched monofocal pseudophakic patients was included to compare contrast sensitivity function.
RESULTS: In the multifocal group, the mean binocular corrected distance visual acuity (logMAR) was -0.04 ± 0.07 at 6 m, 0.11 ± 0.10 at 1 m, and 0.06 ± 0.07 at 40 cm. The defocus curve showed little intermediate vision drop off. Photopic contrast sensitivity for distance was similar to the monofocal IOL contrast sensitivity function, while photopic contrast sensitivity for near and mesopic contrast sensitivity for distance with or without glare was reduced at high frequencies. The mean patient satisfaction was 8.09 ± 1.30 (scale 0 to 10); 84.4% of patients were completely independent of spectacles. Moderate halos, glare, and night-vision problems were reported by 6.2%, 12.5%, and 15.6% of patients, respectively.
CONCLUSION: The new-generation multifocal IOL provided adequate distance, intermediate, and, to a lesser extent, near vision with high rates of spectacle freedom. Halos occurred, and other photic phenomena should be expected in a small percentage of patients. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22018366     DOI: 10.1016/j.jcrs.2011.05.045

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  22 in total

1.  In vitro optical quality comparison between the Mini WELL Ready progressive multifocal and the TECNIS Symfony.

Authors:  Alberto Domínguez-Vicent; Jose Juan Esteve-Taboada; Antonio J Del Águila-Carrasco; Teresa Ferrer-Blasco; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-12-16       Impact factor: 3.117

2.  Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

Authors:  Emilio Pedrotti; Rodolfo Mastropasqua; Jacopo Bonetto; Christian Demasi; Francesco Aiello; Carlo Nucci; Cesare Mariotti; Giorgio Marchini
Journal:  Int Ophthalmol       Date:  2017-07-17       Impact factor: 2.031

3.  The refractive outcome of Toric Lentis Mplus implant in cataract surgery.

Authors:  Patrick J Chiam; Say A Quah
Journal:  Int J Ophthalmol       Date:  2016-05-18       Impact factor: 1.779

4.  Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

Authors:  David P Piñero; Vicente J Camps; María L Ramón; Verónica Mateo; Rafael J Pérez-Cambrodí
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

5.  Presbyopic lens exchange (PRELEX) cataract surgery outcomes with implantation of a rotationally asymmetric refractive multifocal intraocular lens: femtosecond laser-assisted versus manual phacoemulsification.

Authors:  Peter Žiak; Juraj Halička; Peter Mojžiš; Karolína Kapitánová; Javorka Michal; David P Piñero
Journal:  Int Ophthalmol       Date:  2019-06-05       Impact factor: 2.031

6.  Functional assessment of a new extended depth-of-focus intraocular lens.

Authors:  Giacomo Savini; Nicole Balducci; Claudio Carbonara; Scipione Rossi; Manuel Altieri; Nicola Frugis; Emilia Zappulla; Roberto Bellucci; Giovanni Alessio
Journal:  Eye (Lond)       Date:  2018-09-28       Impact factor: 3.775

7.  Comparative analysis of the visual and refractive outcomes of a refractive segmented multifocal intraocular lens with and without toricity: 1-year results.

Authors:  Ryo Shodai; Kazuno Negishi; Hiroyuki Arai; Ikuko Toda; Hidemasa Torii; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2017-01-13       Impact factor: 2.447

8.  Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology.

Authors:  M Ouchi; S Kinoshita
Journal:  Eye (Lond)       Date:  2015-03-06       Impact factor: 3.775

9.  Validity of automated refraction after segmented refractive multifocal intraocular lens implantation.

Authors:  César Albarrán-Diego; Gonzalo Muñoz; Stephanie Rohrweck; Santiago García-Lázaro; José Ricardo Albero
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

10.  Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation.

Authors:  Hungwon Tchah; Kiyeun Nam; Aeri Yoo
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779