PURPOSE: To compare refractive outcomes, higher-order aberrations (HOAs), and contrast sensitivity of myopic wavefront-guided aspheric laser in situ keratomileusis centered on the coaxially sighted corneal light reflex or on the line of sight. SETTING: Okamoto Eye Clinic, Ehime, Japan. DESIGN: Comparative case series. METHODS: Data at 3 months were compared based on the distance between the coaxially sighted corneal light reflex and the line of sight (P-distance) as follows: distance greater than 0.25 mm (high-distance group), distance greater than 0.15 mm and less than 0.25 mm (intermediate-distance group), and distance less than 0.15 mm (low distance group). RESULTS: The chart review included 317 eyes in the corneal-light-reflex group and 269 eyes in the line-of-sight group. The mean postoperative manifest refraction spherical equivalent was +0.123 diopter (D) ± 0.378 (SD) and +0.187 ± 0.480 D, respectively (P = .07). The safety and efficacy indices were significantly higher in the corneal-light-reflex group, including the high-distance subgroup and eyes with a P-distance less than 0.25 mm (P<.05, all cases). The HOAs (P<.001) and coma (P = .001) were significantly higher in the line-of-sight group (P<.001 and P = .001, respectively). The line-of-sight group had a significantly greater change in contrast sensitivity (P = .026). CONCLUSIONS: Centration on the coaxially sighted corneal light reflex resulted in better safety, effectiveness, and contrast sensitivity than line-of-sight centration. Centration on the coaxially sighted corneal light reflex was safer for myopic eyes with P-distances greater than 0.25 mm. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes.
PURPOSE: To compare refractive outcomes, higher-order aberrations (HOAs), and contrast sensitivity of myopic wavefront-guided aspheric laser in situ keratomileusis centered on the coaxially sighted corneal light reflex or on the line of sight. SETTING: Okamoto Eye Clinic, Ehime, Japan. DESIGN: Comparative case series. METHODS: Data at 3 months were compared based on the distance between the coaxially sighted corneal light reflex and the line of sight (P-distance) as follows: distance greater than 0.25 mm (high-distance group), distance greater than 0.15 mm and less than 0.25 mm (intermediate-distance group), and distance less than 0.15 mm (low distance group). RESULTS: The chart review included 317 eyes in the corneal-light-reflex group and 269 eyes in the line-of-sight group. The mean postoperative manifest refraction spherical equivalent was +0.123 diopter (D) ± 0.378 (SD) and +0.187 ± 0.480 D, respectively (P = .07). The safety and efficacy indices were significantly higher in the corneal-light-reflex group, including the high-distance subgroup and eyes with a P-distance less than 0.25 mm (P<.05, all cases). The HOAs (P<.001) and coma (P = .001) were significantly higher in the line-of-sight group (P<.001 and P = .001, respectively). The line-of-sight group had a significantly greater change in contrast sensitivity (P = .026). CONCLUSIONS: Centration on the coaxially sighted corneal light reflex resulted in better safety, effectiveness, and contrast sensitivity than line-of-sight centration. Centration on the coaxially sighted corneal light reflex was safer for myopic eyes with P-distances greater than 0.25 mm. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes.