Literature DB >> 22012707

Pseudo-continuous arterial spin labeling at very high magnetic field (11.75 T) for high-resolution mouse brain perfusion imaging.

Guillaume Duhamel1, Virginie Callot, Mohamed Tachrount, David C Alsop, Patrick J Cozzone.   

Abstract

With the increasing number of transgenic mouse models of human brain diseases, there is a need for a sensitive method that allows assessing quantitative whole brain perfusion within a reasonable scan time. Arterial spin labeling (ASL), an MRI technique that permits the noninvasive quantification of cerebral blood flow, has been used to assess rodents brain perfusion. For mice, the reported experiments performed with continuous or pulsed ASL were challenged by poor multislice capability, limited sensitivity, or quantification issues. Here, the recently proposed pseudo-continuous ASL strategy, which has shown great promise for human studies, was investigated for mouse brain perfusion imaging at 11.75 T. Pseudo-continuous ASL was experimentally optimized and compared with a standard flow-sensitive alternating inversion recovery sequence for sensitivity, robustness, absolute quantification, and multislice imaging capability. A sensitivity gain up to 40% and clear advantages for multislice imaging are obtained with pseudo-continuous ASL.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22012707     DOI: 10.1002/mrm.23096

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  A novel atherothrombotic model of ischemic stroke induced by injection of collagen into the cerebral vasculature.

Authors:  Kathryn J Schunke; Thomas K Toung; Jian Zhang; Arvind P Pathak; Jiadi Xu; Jiangyang Zhang; Raymond C Koehler; Nauder Faraday
Journal:  J Neurosci Methods       Date:  2014-10-12       Impact factor: 2.390

2.  Steady pulsed imaging and labeling scheme for noninvasive perfusion imaging.

Authors:  Jiadi Xu; Qin Qin; Dan Wu; Jun Hua; Xiaolei Song; Michael T McMahon; Frances J Northington; Jiangyang Zhang; Peter C M van Zijl; James J Pekar
Journal:  Magn Reson Med       Date:  2015-03-02       Impact factor: 4.668

3.  Cerebrovascular reactivity measured with arterial spin labeling and blood oxygen level dependent techniques.

Authors:  Yongxia Zhou; Zachary B Rodgers; Anderson H Kuo
Journal:  Magn Reson Imaging       Date:  2015-02-20       Impact factor: 2.546

Review 4.  Translational MR Neuroimaging of Stroke and Recovery.

Authors:  Emiri T Mandeville; Cenk Ayata; Yi Zheng; Joseph B Mandeville
Journal:  Transl Stroke Res       Date:  2016-08-31       Impact factor: 6.829

5.  Optimized cervical spinal cord perfusion MRI after traumatic injury in the rat.

Authors:  Briana P Meyer; Lydiane Hirschler; Seongtaek Lee; Shekar N Kurpad; Jan M Warnking; Emmanuel L Barbier; Matthew D Budde
Journal:  J Cereb Blood Flow Metab       Date:  2021-01-28       Impact factor: 6.200

6.  Age-Related Alterations in Brain Perfusion, Venous Oxygenation, and Oxygen Metabolic Rate of Mice: A 17-Month Longitudinal MRI Study.

Authors:  Zhiliang Wei; Lin Chen; Xirui Hou; Peter C M van Zijl; Jiadi Xu; Hanzhang Lu
Journal:  Front Neurol       Date:  2020-06-12       Impact factor: 4.003

7.  Sensitivity of Multiphase Pseudocontinuous Arterial Spin Labelling (MP pCASL) Magnetic Resonance Imaging for Measuring Brain and Tumour Blood Flow in Mice.

Authors:  Jessica Buck; James R Larkin; Manon A Simard; Alexandre A Khrapitchev; Michael A Chappell; Nicola R Sibson
Journal:  Contrast Media Mol Imaging       Date:  2018-11-07       Impact factor: 3.161

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.