Literature DB >> 22009295

Passive ammonia monitoring in the United States: comparing three different sampling devices.

Melissa A Puchalski1, Mark E Sather, John T Walker, Christopher M B Lehmann, David A Gay, Johnson Mathew, Wayne P Robarge.   

Abstract

The need for ambient gaseous ammonia (NH(3)) measurements has increased in the last decade as reactive NH(3) concentrations and deposition fluxes show little change even with tightening standards on nitrogen oxides (NO(x)) emissions. Currently, there are several networks developing methods for adding NH(3) measurements in the U.S. Gaseous NH(3) measurements will provide scientists and policymakers data which can be used to estimate ecosystem inputs, validate air quality models including trends and regional variability, and evaluate changes to the environment based on additional emission reduction requirements and estimates of critical nitrogen load exceedances. The passive samplers described in this paper were deployed in duplicate or triplicate and collocated with annular denuders or continuous instruments to determine their accuracy. The samplers assessed included the Adapted Low-Cost Passive High Absorption (ALPHA), Radiello(®), and Ogawa passive samplers. The median relative percent differences (MRPD) between the reference method and passive samplers for the ALPHA, Radiello(®) and Ogawa were -2.4%, -37% and -44%, respectively. The precision between duplicate samplers for the ALPHA and Ogawa samplers, was 7% and 6%, respectively. Triplicate Radiello(®) precision was assessed using the coefficient of variation (CV). The CV for the Radiello(®) samplers was 10%. This article discusses the statistical results from these studies.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22009295     DOI: 10.1039/c1em10553a

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  5 in total

1.  Calibrated Passive Sampling--Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers.

Authors:  Andreas Pacholski
Journal:  J Vis Exp       Date:  2016-03-21       Impact factor: 1.355

2.  The home air in agriculture pediatric intervention (HAPI) trial: Rationale and methods.

Authors:  Erin E Masterson; Lisa B Younglove; Adriana Perez; Elizabeth Torres; Jennifer E Krenz; Maria I Tchong French; Anne M Riederer; Paul D Sampson; Nervana Metwali; Esther Min; Karen L Jansen; Gino Aisenberg; Ryan S Babadi; Stephanie A Farquhar; Peter S Thorne; Catherine J Karr
Journal:  Contemp Clin Trials       Date:  2020-07-25       Impact factor: 2.226

Review 3.  δ15N-stable isotope analysis of NH x : An overview on analytical measurements, source sampling and its source apportionment.

Authors:  Noshan Bhattarai; Shuxiao Wang; Yuepeng Pan; Qingcheng Xu; Yanlin Zhang; Yunhua Chang; Yunting Fang
Journal:  Front Environ Sci Eng       Date:  2021-03-15

4.  New Bidirectional Ammonia Flux Model in an Air Quality Model Coupled With an Agricultural Model.

Authors:  Jonathan E Pleim; Limei Ran; Wyat Appel; Mark W Shephard; Karen Cady-Pereira
Journal:  J Adv Model Earth Syst       Date:  2019-10-24       Impact factor: 6.660

5.  Assessment of Indoor Air Quality for Group-Housed Macaques (Macaca spp.).

Authors:  Annemiek Maaskant; Isabel Janssen; Inge M Wouters; Frank J C M van Eerdenburg; Edmond J Remarque; Jan A M Langermans; Jaco Bakker
Journal:  Animals (Basel)       Date:  2022-07-07       Impact factor: 3.231

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.