Literature DB >> 22003644

Cortical surface strain estimation using stereovision.

Songbai Ji1, Xiaoyao Fan, David W Roberts, Keith D Paulsen.   

Abstract

We present a completely noninvasive technique to estimate soft tissue surface strain by differentiating three-dimensional displacements obtained from optical flow motion tracking using stereo images. The implementation of the strain estimation algorithm was verified with simulated data and its application was illustrated in three open cranial neurosurgical cases, where cortical surface strain induced by arterial blood pressure pulsation was evaluated. Local least squares smoothing was applied to the displacement field prior to strain estimation to reduce the effect of noise during differentiation. Maximum principal strains (epsilon1) of up to 7% were found in the exposed cortical area on average, and the largest strains (up to -18%) occurred near the craniotomy rim with the majority of epsilon1 perpendicular to the boundary, indicating relative stretching along this direction. The technique offers a new approach for soft tissue strain estimation for the purpose of biomechanical characterization.

Entities:  

Mesh:

Year:  2011        PMID: 22003644      PMCID: PMC3774044          DOI: 10.1007/978-3-642-23623-5_52

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  4 in total

1.  Stereopsis-guided brain shift compensation.

Authors:  Hai Sun; Karen E Lunn; Hany Farid; Ziji Wu; David W Roberts; Alex Hartov; Keith D Paulsen
Journal:  IEEE Trans Med Imaging       Date:  2005-08       Impact factor: 10.048

2.  Clinical proof of the importance of compliance for hydrocephalus pathophysiology.

Authors:  Michael Kiefer; Regina Eymann
Journal:  Acta Neurochir Suppl       Date:  2010

3.  Experimental surface strain mapping of porcine peripapillary sclera due to elevations of intraocular pressure.

Authors:  Michaël J A Girard; J Crawford Downs; Claude F Burgoyne; J-K Francis Suh
Journal:  J Biomech Eng       Date:  2008-08       Impact factor: 2.097

4.  A surface registration method for quantification of intraoperative brain deformations in image-guided neurosurgery.

Authors:  Perrine Paul; Xavier Morandi; Pierre Jannin
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-06-19
  4 in total
  4 in total

1.  Efficient stereo image geometrical reconstruction at arbitrary camera settings from a single calibration.

Authors:  Songbai Ji; Xiaoyao Fan; David W Roberts; Keith D Paulsen
Journal:  Med Image Comput Comput Assist Interv       Date:  2014

2.  Use of Stereovision for Intraoperative Coregistration of a Spinal Surgical Field: A Human Feasibility Study.

Authors:  S Scott Lollis; Xiaoyao Fan; Linton Evans; Jonathan D Olson; Keith D Paulsen; David W Roberts; Sohail K Mirza; Songbai Ji
Journal:  Oper Neurosurg (Hagerstown)       Date:  2018-01-01       Impact factor: 2.703

3.  Biomechanical model as a registration tool for image-guided neurosurgery: evaluation against BSpline registration.

Authors:  Ahmed Mostayed; Revanth Reddy Garlapati; Grand Roman Joldes; Adam Wittek; Aditi Roy; Ron Kikinis; Simon K Warfield; Karol Miller
Journal:  Ann Biomed Eng       Date:  2013-06-15       Impact factor: 3.934

4.  Cortical surface shift estimation using stereovision and optical flow motion tracking via projection image registration.

Authors:  Songbai Ji; Xiaoyao Fan; David W Roberts; Alex Hartov; Keith D Paulsen
Journal:  Med Image Anal       Date:  2014-07-09       Impact factor: 8.545

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.