Literature DB >> 22000466

Comparison of autoclaving effects on torsional deformation and fracture resistance of three innovative endodontic file systems.

Rhett B Casper1, Howard W Roberts, Mark D Roberts, Van T Himel, Brian E Bergeron.   

Abstract

INTRODUCTION: Recent innovative manufacturing techniques have produced nickel-titanium (NiTi) rotary instruments with reports of superior properties compared with standard NiTi files. These include Profile Vortex made from M-Wire (PV), Twisted Files (TF), and 10 Series files made from CM Wire (CM). Sterilization is recommended before use and is repeated if files are reused and/or carried forward between cases. The purpose for this study was to compare the effects of multiple autoclaving cycles on the torsional load resistance of these 3 new rotary endodontic files.
METHODS: PV, TF, and CM files (n = 100; size 25/.04) were divided into 5 groups (n = 20). Files were steam autoclaved for 1, 2, 3, and 7 sterilization cycles. A control group was not subjected to autoclaving. Files were tested in a torsiometer in general accordance with ISO 3630-1 standards. Torsional load and degrees of rotation to failure were recorded. Mean data were analyzed by using Kruskal-Wallace/Dunn post hoc tests (P < .05).
RESULTS: Autoclave cycles had no significant overall effect on file performance for any of the instrument systems tested. PV and CM displayed significantly greater resistance to torsional load than TF (P < .001) but were not different from each other (P > .05). Angular deflection values for TF and CM were significantly higher than for PV (P < .001), with TF demonstrating greater rotational distortion than CM (P < .05).
CONCLUSIONS: Under the conditions of this study, repeated steam autoclaving did not affect torsional resistance for unused files of the systems evaluated. In addition, CM Wire files might have a combined advantage of greater torsional strength and high deformation before failure. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22000466     DOI: 10.1016/j.joen.2011.07.008

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  7 in total

1.  Assessment of the Centralization of Root Canal Preparation with Rotary Systems.

Authors:  Daniela Siqueira Lopes; Mariana Albuquerque Veiga Pessoa; Carlos Menezes Aguiar
Journal:  Acta Stomatol Croat       Date:  2016-09

2.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

Authors:  K Yılmaz; G Uslu; T Özyürek
Journal:  Clin Oral Investig       Date:  2018-02-13       Impact factor: 3.573

3.  Effect of autoclave sterilization on cyclic fatigue and torsional fracture resistance of NiTi rotary instruments.

Authors:  Wooyoung Kim; Soram Oh; Gil-Joo Ryu; Tae-Hwan Kim; Sung-Jae Kim; Dong-Hyung Kim; Bin-Na Lee; Kee-Yeon Kum; Seok Woo Chang; Ji-Hyun Jang
Journal:  Odontology       Date:  2019-09-11       Impact factor: 2.634

Review 4.  Nickel-Titanium Rotary File Systems: What's New?

Authors:  Sadia Tabassum; Kamil Zafar; Fahad Umer
Journal:  Eur Endod J       Date:  2019-10-18

5.  Effect of Sterilization on Cyclic Fatigue Resistance of Proflexendo Endodontic Rotary Files.

Authors:  Emad O Alshwaimi
Journal:  Saudi J Med Med Sci       Date:  2019-02-08

6.  Torsional and Bending Properties of V Taper 2H, ProTaper NEXT, NRT, and One Shape.

Authors:  Soram Oh; Kee-Yeon Kum; Kwon Cho; Soo-Hyuk Lee; Seung-Hyun You; Jonggun Go; Bong-Ki Jeon; Sang-Woo Kim; Tae-Hwan Kim; Ji-Hyun Jang; Hiran Perinpanayagam; Jin-Woo Kim; Seok Woo Chang
Journal:  Biomed Res Int       Date:  2019-11-07       Impact factor: 3.411

Review 7.  Management of Instrument Sterilization Workflow in Endodontics: A Systematic Review and Meta-Analysis.

Authors:  Mario Dioguardi; Diego Sovereto; Gaetano Illuzzi; Enrica Laneve; Bruna Raddato; Claudia Arena; Vito Carlo Alberto Caponio; Giorgia Apollonia Caloro; Khrystyna Zhurakivska; Giuseppe Troiano; Lorenzo Lo Muzio
Journal:  Int J Dent       Date:  2020-02-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.