Literature DB >> 22000462

Influence of different manufacturing methods on the cyclic fatigue of rotary nickel-titanium endodontic instruments.

Renata C V Rodrigues1, Hélio P Lopes, Carlos N Elias, Georgiana Amaral, Victor T L Vieira, Alexandre S De Martin.   

Abstract

INTRODUCTION: The aim of this study was to evaluate, by static and dynamic cyclic fatigue tests, the number of cycles to fracture (NCF) 2 types of rotary NiTi instruments: Twisted File (SybronEndo, Orange, CA), which is manufactured by a proprietary twisting process, and RaCe files (FKG Dentaire, La Chaux-de-Fonds, Switzerland), which are manufactured by grinding.
METHODS: Twenty Twisted Files (TFs) and 20 RaCe files #25/.006 taper instruments were allowed to rotate freely in an artificial curved canal at 310 rpm in a static or a dynamic model until fracture occurred.
RESULTS: Measurements of the fractured fragments showed that fracture occurred at the point of maximum flexure in the midpoint of the curved segment. The NCF was significantly lower for RaCe instruments compared with TFs. The NCF was also lower for instruments subjected to the static test compared with the dynamic model in both groups. Scanning electron microscopic analysis revealed ductile morphologic characteristics on the fractured surfaces of all instruments and no plastic deformation in their helical shafts.
CONCLUSIONS: Rotary NiTi endodontic instruments manufactured by twisting present greater resistance to cyclic fatigue compared with instruments manufactured by grinding. The fracture mode observed in all instruments was of the ductile type.
Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22000462     DOI: 10.1016/j.joen.2011.08.011

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  10 in total

1.  Shaping ability of two nickel-titanium instruments activated by continuous rotation or adaptive motion: a micro-computed tomography study.

Authors:  E Pedullà; G Plotino; N M Grande; G Avarotti; G Gambarini; E Rapisarda; F Mannocci
Journal:  Clin Oral Investig       Date:  2016-02-15       Impact factor: 3.573

2.  Analysis of the Importance of the Motion Used in the Resistance of Different Mechanical Instrumentation Systems in Endodontics: A Comparative Study.

Authors:  Jesús Mena-Álvarez; Manuel Almanzor-López; Norberto Quispe-López; Ana De Pedro-Muñoz; Cristina Rico-Romano
Journal:  Materials (Basel)       Date:  2022-06-24       Impact factor: 3.748

3.  Effect of Rotational Speed on the Resistance of NiTi Alloy Endodontic Rotary Files to Cyclic Fatigue-An In Vitro Study.

Authors:  Vicente Faus-Matoses; Vicente Faus-Llácer; Celia Ruiz-Sánchez; Sharon Jaramillo-Vásconez; Ignacio Faus-Matoses; Benjamín Martín-Biedma; Álvaro Zubizarreta-Macho
Journal:  J Clin Med       Date:  2022-05-31       Impact factor: 4.964

4.  Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatment.

Authors:  Taha Özyürek; Koray Yılmaz; Gülşah Uslu
Journal:  Restor Dent Endod       Date:  2016-12-19

Review 5.  Rotary science and its impact on instrument separation: A focused review.

Authors:  Sandhya Anand Khasnis; Prem Prakash Kar; Apoorva Kamal; Jayaprakash D Patil
Journal:  J Conserv Dent       Date:  2018 Mar-Apr

6.  Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire.

Authors:  Gianluca Gambarini; Massimo Galli; Dario Di Nardo; Marco Seracchiani; Orlando Donfrancesco; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-07-01

7.  Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files.

Authors:  Álvaro Zubizarreta-Macho; Jesús Mena Álvarez; Alberto Albaladejo Martínez; Juan José Segura-Egea; Javier Caviedes Brucheli; Rubén Agustín-Panadero; Roberto López Píriz; Óscar Alonso-Ezpeleta
Journal:  J Clin Med       Date:  2019-12-24       Impact factor: 4.241

8.  Influence of Sodium Hypochlorite and Chlorhexidine on the Dynamic Cyclic Fatigue Resistance of XP Endo Shaper Instruments.

Authors:  Alexandra Aparecida Tanomaru; Ana Grasiela Limoeiro; Adriana de Jesus Soares; Elson Lopes Medeiros Junior; Gabriel Rocha Campos; Sílvia Kaoru Hamasaki; Wayne Martins Nascimento; Luiz Meton Horta; Paula Avelar da Silva Ribeiro Goulart; Viviane Rangel do Couto; Patrícia Bastos Alves; Verônica Magalhães; Danilo De Luca Campos; Marcos Frozoni
Journal:  Eur J Dent       Date:  2021-12-22

9.  Shot peening increases resistance to cyclic fatigue fracture of endodontic files.

Authors:  Javier Nino-Barrera; Jose Sanchez-Aleman; Manuel Acosta-Humanez; Luis Gamboa-Martinez; Carlos Cortes-Rodriguez
Journal:  Sci Rep       Date:  2021-06-21       Impact factor: 4.379

10.  Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis.

Authors:  Leandro de Arruda Santos; Pedro Damas Resende; Maria Guiomar de Azevedo Bahia; Vicente Tadeu Lopes Buono
Journal:  ScientificWorldJournal       Date:  2016-05-22
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.