Literature DB >> 21997317

Randomized clinical trial comparing the cost and effectiveness of bipolar vessel sealers versus clips and vascular staplers for laparoscopic colorectal resection.

M Adamina1, B J Champagne, L Hoffman, M B Ermlich, C P Delaney.   

Abstract

BACKGROUND: The widespread use of laparoscopy has resulted in a variety of instruments being used routinely for vascular control. This randomized controlled trial evaluated the cost-effectiveness of bipolar vessel sealer (BVS) compared with clips and vascular stapler (CVS) in straight laparoscopic colorectal resection.
METHODS: Patients scheduled for elective colorectal resection, including benign and malignant diseases, were randomized to either BVS or CVS for vascular control. Patients whose operation was converted to an open approach before pedicle ligation were excluded. The primary endpoints were duration of operation, including time taken to control vascular pedicles, and cost of disposable instruments for vascular control.
RESULTS: Of 114 patients randomized to BVS (60 patients) or CVS (54), 14 did not receive the allocated vascular control device, leaving 55 and 45 respectively for analysis. The BVS reduced the time spent for vascular control by a mean of 6·9 min (P = 0·031) and reduced the cost of disposable instruments for vascular control by US $ 80·7 per patient (P = 0·043). For total colectomy, the BVS reduced the operating time by 103·6 min (P = 0·023) and the time taken for vascular control by 16·8 min (P = 0·022). For left colectomy, it decreased the time to vascular control by 9·3 min (P = 0·021). In multivariable analysis, the cost of disposable instruments for vascular control was independently reduced by randomization to BVS, type of procedure, female sex and estimated blood loss. The mean cost reduction was $ 88·2 for left colectomy (P = 0·037), $ 377·7 (P = 0·005) for total colectomy and $ 366·9 (P = 0·012) for proctectomy. Conversely, use of the BVS increased the cost of instruments used for vascular control in right colectomy by $ 92·6 (P = 0·012).
CONCLUSION: BVS devices are expedient and cost-efficient in proctectomy, left and total colectomy procedures.
Copyright © 2011 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 21997317     DOI: 10.1002/bjs.7679

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  7 in total

1.  Energy vessel sealing systems versus mechanical ligature of the inferior mesenteric artery in laparoscopic sigmoidectomy.

Authors:  Bertrand Trilling; Romain Riboud; Julio Abba; Edouard Girard; Jean-Luc Faucheron
Journal:  Int J Colorectal Dis       Date:  2016-02-03       Impact factor: 2.571

2.  Monitoring c-reactive protein after laparoscopic colorectal surgery excludes infectious complications and allows for safe and early discharge.

Authors:  Michel Adamina; Rene Warschkow; Franziska Näf; Bianka Hummel; Thomas Rduch; Jochen Lange; Thomas Steffen
Journal:  Surg Endosc       Date:  2014-05-23       Impact factor: 4.584

Review 3.  The evolution of cancer surgery and future perspectives.

Authors:  Lynda Wyld; Riccardo A Audisio; Graeme J Poston
Journal:  Nat Rev Clin Oncol       Date:  2014-11-11       Impact factor: 66.675

Review 4.  Learning curve in robotic rectal cancer surgery: current state of affairs.

Authors:  Rosa M Jiménez-Rodríguez; Mercedes Rubio-Dorado-Manzanares; José Manuel Díaz-Pavón; M Luisa Reyes-Díaz; Jorge Manuel Vazquez-Monchul; Ana M Garcia-Cabrera; Javier Padillo; Fernando De la Portilla
Journal:  Int J Colorectal Dis       Date:  2016-10-06       Impact factor: 2.571

5.  Laparoscopic complete mesocolic excision for right colon cancer.

Authors:  Michel Adamina; Mark L Manwaring; Ki-Jae Park; Conor P Delaney
Journal:  Surg Endosc       Date:  2012-05-02       Impact factor: 4.584

6.  Efficacy and Safety of Combined Ultrasonic and Bipolar Energy Source in Laparoscopic Surgery.

Authors:  Daniel C Steinemann; Sebastian H Lamm; Andreas Zerz
Journal:  J Gastrointest Surg       Date:  2016-07-25       Impact factor: 3.452

Review 7.  Robotic colorectal surgery.

Authors:  Carrie Y Peterson; Martin R Weiser
Journal:  J Gastrointest Surg       Date:  2013-08-16       Impact factor: 3.452

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.