Literature DB >> 21993985

Off-resonance artifacts correction with convolution in k-space (ORACLE).

Wei Lin1, Feng Huang, Enrico Simonotto, George R Duensing, Arne Reykowski.   

Abstract

Off-resonance artifacts hinder the wider applicability of echo-planar imaging and non-Cartesian MRI methods such as radial and spiral. In this work, a general and rapid method is proposed for off-resonance artifacts correction based on data convolution in k-space. The acquired k-space is divided into multiple segments based on their acquisition times. Off-resonance-induced artifact within each segment is removed by applying a convolution kernel, which is the Fourier transform of an off-resonance correcting spatial phase modulation term. The field map is determined from the inverse Fourier transform of a basis kernel, which is calibrated from data fitting in k-space. The technique was demonstrated in phantom and in vivo studies for radial, spiral and echo-planar imaging datasets. For radial acquisitions, the proposed method allows the self-calibration of the field map from the imaging data, when an alternating view-angle ordering scheme is used. An additional advantage for off-resonance artifacts correction based on data convolution in k-space is the reusability of convolution kernels to images acquired with the same sequence but different contrasts.
Copyright © 2011 Wiley-Liss, Inc.

Mesh:

Year:  2011        PMID: 21993985     DOI: 10.1002/mrm.23135

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Deep residual network for off-resonance artifact correction with application to pediatric body MRA with 3D cones.

Authors:  David Y Zeng; Jamil Shaikh; Signy Holmes; Ryan L Brunsing; John M Pauly; Dwight G Nishimura; Shreyas S Vasanawala; Joseph Y Cheng
Journal:  Magn Reson Med       Date:  2019-05-22       Impact factor: 4.668

2.  B0 mapping using rewinding trajectories (BMART).

Authors:  Corey A Baron; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2016-08-24       Impact factor: 4.668

3.  Two-dimensional XD-GRASP provides better image quality than conventional 2D cardiac cine MRI for patients who cannot suspend respiration.

Authors:  Eve Piekarski; Teodora Chitiboi; Rebecca Ramb; Larry A Latson; Puneet Bhatla; Li Feng; Leon Axel
Journal:  MAGMA       Date:  2017-10-24       Impact factor: 2.310

4.  Technical Note: Effects of rotating gantry on magnetic field and eddy currents in 0.35 T MRI-guided radiotherapy (MR-IGRT) system.

Authors:  H Michael Gach; Austen N Curcuru; Taeho Kim; Deshan Yang
Journal:  Med Phys       Date:  2021-09-25       Impact factor: 4.506

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.