Literature DB >> 21988331

Turn-on room temperature phosphorescence assay of heparin with tunable sensitivity and detection window based on target-induced self-assembly of polyethyleneimine capped Mn-doped ZnS quantum dots.

Huan Yan1, He-Fang Wang.   

Abstract

Room-temperature phosphorescence (RTP) turn-on assay of heparin with tunable sensitivity and detection window was demonstrated on the basis of the target induced self-assembly of polyethyleneimine capped Mn-doped ZnS (PEI-Mn-ZnS) QDs. The proposed method can cover the whole therapeutic dosing concentration range in postoperation and long-term therapy (0.2-1.2 U/mL, 1.7-10 μM) and cardiovascular surgery (2-8 U/mL, 17-67 μM) in 10 mM Tris-HCl (pH 7.4) buffer and can be applied for heparin determination in 100-fold diluted human serum samples. The tunable sensitivity and detection window was ascribed to the tunable particle size and ligand loading amount of PEI-Mn-ZnS QD arising from the chain length (or molecule weight) and feed amount of PEI. The chain length of PEI exhibited significant effect on the particle size and ligand loading amount and ultimately had important influence on both the sensitivity and detection window. The feeding amount of PEI, however, greatly affected the ligand loading amount alone and, in turn, affected only the detection window.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21988331     DOI: 10.1021/ac201992p

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Magnetic nanoparticles coated with a molecularly imprinted polymer doped with manganese-doped ZnS quantum dots for the determination of 2,4,6-trichlorophenol.

Authors:  Xiao Wei; Miaomiao Yu; Chen Li; Xinghui Gong; Fang Qin; Zhenhong Wang
Journal:  Mikrochim Acta       Date:  2018-03-05       Impact factor: 5.833

2.  A label-free RTP sensor based on aptamer/quantum dot nanocomposites for cytochrome c detection.

Authors:  Dongxia Li; Junping Guo; Liang Zhao; Guoxian Zhang; Guiqin Yan
Journal:  RSC Adv       Date:  2019-10-08       Impact factor: 4.036

3.  A ratiometric fluorometric heparin assay based on the use of CdTe and polyethyleneimine-coated carbon quantum dots.

Authors:  Si-Si Liang; Xu Deng; Yao-Yao Fan; Jun Li; Man Wang; Zhi-Qi Zhang
Journal:  Mikrochim Acta       Date:  2018-10-25       Impact factor: 5.833

4.  Chitosan-capped gold nanoparticles for selective and colorimetric sensing of heparin.

Authors:  Zhanguang Chen; Zhen Wang; Xi Chen; Haixiong Xu; Jinbin Liu
Journal:  J Nanopart Res       Date:  2013-08-25       Impact factor: 2.253

5.  AS1411 aptamer modified carbon dots via polyethylenimine-assisted strategy for efficient targeted cancer cell imaging.

Authors:  Tingting Kong; Ronghui Zhou; Yujun Zhang; Liying Hao; Xiaoxiao Cai; Bofeng Zhu
Journal:  Cell Prolif       Date:  2019-11-05       Impact factor: 6.831

6.  Phosphorescent immunosensor for simple and sensitive detection of microcystin-LR in water.

Authors:  Jin Qin; Xiaojie Sun; Dongxia Li; Guiqin Yan
Journal:  RSC Adv       Date:  2019-04-25       Impact factor: 3.361

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.