Literature DB >> 21986306

A mechano-acoustic indentor system for in vivo measurement of nonlinear elastic properties of soft tissue.

Terry K Koo1, Jeffrey H Cohen, Yongping Zheng.   

Abstract

OBJECTIVES: Soft tissue exhibits nonlinear stress-strain behavior under compression. Characterizing its nonlinear elasticity may aid detection, diagnosis, and treatment of soft tissue abnormality. The purposes of this study were to develop a rate-controlled Mechano-Acoustic Indentor System and a corresponding finite element optimization method to extract nonlinear elastic parameters of soft tissue and evaluate its test-retest reliability.
METHODS: An indentor system using a linear actuator to drive a force-sensitive probe with a tip-mounted ultrasound transducer was developed. Twenty independent sites at the upper lateral quadrant of the buttock from 11 asymptomatic subjects (7 men and 4 women from a chiropractic college) were indented at 6% per second for 3 sessions, each consisting of 5 trials. Tissue thickness, force at 25% deformation, and area under the load-deformation curve from 0% to 25% deformation were calculated. Optimized hyperelastic parameters of the soft tissue were calculated with a finite element model using a first-order Ogden material model. Load-deformation response on a standardized block was then simulated, and the corresponding area and force parameters were calculated. Between-trials repeatability and test-retest reliability of each parameter were evaluated using coefficients of variation and intraclass correlation coefficients, respectively.
RESULTS: Load-deformation responses were highly reproducible under repeated measurements. Coefficients of variation of tissue thickness, area under the load-deformation curve from 0% to 25% deformation, and force at 25% deformation averaged 0.51%, 2.31%, and 2.23%, respectively. Intraclass correlation coefficients ranged between 0.959 and 0.999, indicating excellent test-retest reliability.
CONCLUSIONS: The automated Mechano-Acoustic Indentor System and its corresponding optimization technique offers a viable technology to make in vivo measurement of the nonlinear elastic properties of soft tissue. This technology showed excellent between-trials repeatability and test-retest reliability with potential to quantify the effects of a wide variety of manual therapy techniques on the soft tissue elastic properties.
Copyright © 2011 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21986306     DOI: 10.1016/j.jmpt.2011.05.009

Source DB:  PubMed          Journal:  J Manipulative Physiol Ther        ISSN: 0161-4754            Impact factor:   1.437


  4 in total

1.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

2.  Nonlinear Elasticity Assessment with Optical Coherence Elastography for High-Selectivity Differentiation of Breast Cancer Tissues.

Authors:  Ekaterina V Gubarkova; Aleksander A Sovetsky; Lev A Matveev; Aleksander L Matveyev; Dmitry A Vorontsov; Anton A Plekhanov; Sergey S Kuznetsov; Sergey V Gamayunov; Alexey Y Vorontsov; Marina A Sirotkina; Natalia D Gladkova; Vladimir Y Zaitsev
Journal:  Materials (Basel)       Date:  2022-05-05       Impact factor: 3.748

3.  An inverse method to determine the mechanical properties of the iris in vivo.

Authors:  Kunya Zhang; Xiuqing Qian; Xi Mei; Zhicheng Liu
Journal:  Biomed Eng Online       Date:  2014-05-30       Impact factor: 2.819

4.  Using an interactive virtual environment to integrate a digital Action Research Arm Test, motor imagery and action observation to assess and improve upper limb motor function in patients with neuromuscular impairments: a usability and feasibility study protocol.

Authors:  Frank Behrendt; Corina Schuster-Amft
Journal:  BMJ Open       Date:  2018-07-16       Impact factor: 2.692

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.